LogoIVM 60/36-3IVM 100/36-3
  • General instructions
  • Safety information
    • Hazard levels
    • General safety instructions
    • Behaviour in the event of an emergency
  • Intended use
  • Environmental protection
  • Accessories and spare parts
  • Description of the device
  • Initial startup
    • Fitting the dust collection bag
  • Operation
    • Switching on the device
    • Performing the vacuuming process
    • Wet vacuum cleaning
    • Switching from wet to dry vacuuming
    • Cleaning the filter
    • Switching off the device
    • Each time after use
      • Emptying the dirt receptacle
  • Transport
  • Storage
  • Care and service
    • Inspection and maintenance work
    • Maintenance intervals / user maintenance
      • Wash the filter
      • Changing/replacing the filter
  • Troubleshooting guide
    • Suction turbine does not start up

    • Suction power decreases

    • Escaping dust when vacuuming

  • Disposal
  • Warranty
  • Technical data
    • IVM 60/36-3
    • IVM 100/36-3
  • Declaration of Conformity

      IVM 60/36-3
      IVM 100/36-3

      59686660 (04/24)

      General instructions

      Read these original instructions before using your device for the first time, adhere to the instructions contained therein and store them for later reference or subsequent owners.

      • Be sure to read the safety instructions no. 5.956-249.0 prior to the initial startup.

      • If the operating instructions and safety instructions are not observed, the device can be damaged and dangers could arise for users and other persons.

      • Notify the dealer immediately in the case of shipping damage.

      Safety information

      Hazard levels

      DANGER

      Indication of an imminent threat of danger that will lead to severe injuries or even death.

      WARNING

      Indication of a potentially dangerous situation that may lead to severe injuries or even death.

      CAUTION

      Indication of a potentially dangerous situation that may lead to minor injuries.

      ATTENTION

      Indication of a potentially dangerous situation that may lead to damage to property.

      General safety instructions

      It is essential to read the enclosed safety instructions for wet/dry vacuum cleaners before using the device for the first time!

      DANGER

      Observe the applicable safety instructions for the materials being vacuumed.

      WARNING

      The device is not suitable for vacuuming up dusts that are harmful to human health.

      WARNING

      The device must not be used or stored outdoors in wet conditions.

      WARNING

      Apply the parking brake at the steering roller to ensure a secure footing for the device. The device may move uncontrollably if the parking brake is open.

      CAUTION

      In case of longer breaks in operation and after use, switch off the device at the power switches and unplug the mains plug.

      Behaviour in the event of an emergency

      DANGER

      Risk of injury and damage in the event of a short-circuit or other electrical faults

      Danger of electric shock, danger of burns

      Switch off the device and unplug the mains plug.

      Intended use

      The device is intended for:

      • Wet and dry cleaning of floor and wall surfaces

      • For vacuuming moist or liquid substances

      • Vacuuming dry, non-flammable dusts from machines

      • Industrial usee.g. in storage and production areas

      • Commercial use, e.g. in hotels, schools, hospitals, factories, shops, offices, and rental companies.

      Any other use constitutes improper use.

      The device must not be used for the following purposes:

      • Vacuuming of dangerous dusts

      • Crane loading

      Environmental protection

      The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.

      Electrical and electronic devices contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which - if handled or disposed of incorrectly - can pose a potential danger to human health and the environment. However, these components are required for the correct operation of the device. Devices marked by this symbol are not allowed to be disposed of together with the household rubbish.

      Notes on the content materials (REACH)

      Current information on content materials can be found at: www.kaercher.de/REACH

      Accessories and spare parts

      Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.

      Information on accessories and spare parts can be found at www.kaercher.com.

      Description of the device


      1. Steering roller with parking brake
      2. Dirt receptacle
      3. Filter ring
      4. Suction pipe holder
      5. Spacer
      6. Type plate
      7. Mains cable
      8. Cable hooks
      9. Carrying handle
      10. filter
      11. Sealing ring
      12. Filter vibrator
      13. Lever for the filter cleaning
      14. Suction turbine trigger 3
      15. Suction turbine trigger 1
      16. Suction turbine trigger 2
      17. Suction head
      18. Suction head lock
      19. Push handle
      20. Floor nozzle holder
      21. Suction hose port
      22. Bow handle of the dirt receptacle
      23. Spacer lock
      24. Cable clips
      25. Chassis

      Initial startup

      ATTENTION

      Exceeding the grid impedance

      Electrical shock in the event of a short-circuit

      The maximum permissible mains grid impedance at the electrical connection point (see Technical data) must not be exceeded.

      Contact your electricity supplier in the case of any uncertainties regarding the mains grid impedance at your electrical connection point.

      1. Bring the device into the working position.

      2. Secure the device with the parking brakes.

      3. Insert the suction hose into the suction connection.

      4. Plug the desired accessory onto the suction hose.

      5. If necessary, fit a dust collection bag in the dirt receptacle (see chapter Fitting the dust collection bag).

      6. Ensure that the dirt receptacle is correctly fitted.

      Fitting the dust collection bag

      A dust collection bag can be inserted into the dirt receptacle to allow dust-free emptying of the device.

      Note

      The dust collection bag must not be used for wet vacuum cleaning.

      1. Fit the dust collection bag in the dirt receptacle and carefully press it against the wall of the container.

      2. Fold the edge of the bag over the edge of the dirt receptacle.

      3. WARNING

        Improper handling when locking the dirt receptacle

        Risk of crushing

        Under no circumstances should you hold your hands between the dirt receptacle and filter ring or allow them to come close to the lifting mechanism while locking it.

        Lock the dirt receptacle by operating the bow handle with both hands.

      4. Fit the dirt receptacle in the device.

      Operation

      After vacuuming moist or liquid substances, see chapter Switching from wet to dry vacuuming.

      Switching on the device

      1. Plug the mains plug into the socket.

      2. Switch on the device via the suction turbine power switches.

        Note

        Select the required suction power via the suction turbine power switch, starting with suction turbine 1. Always switch the suction turbines on and off one after the other.

      3. Start the vacuuming process.

      Performing the vacuuming process

      1. Regularly check the filling level in the dirt receptacle, since the device does not switch off automatically.

      2. If necessary, empty the dirt receptacle (see chapter Emptying the dirt receptacle).

      3. If necessary, clean the filter (see chapter Cleaning the filter) or change/replace the filter (see chapter Changing/replacing the filter).

      Wet vacuum cleaning

      ATTENTION

      Risk of damage if the dirt receptacle overflows

      The dirt receptacle can fill within a few seconds and overflow when vacuuming large amounts of liquids.

      Continuously monitor the filling level.

      1. Remove the dust collection bag, if necessary, before wet vacuum cleaning (see chapter Emptying the dirt receptacle).

      2. After wet vacuum cleaning:

        1. Dry the filter.

        2. Clean the dirt receptacle with a moist cloth and dry it off.

      Switching from wet to dry vacuuming

      ATTENTION

      Switching from wet to dry vacuuming

      Risk of damage to the filter

      Do not vacuum dry dust with a wet filter element because this clogs the filter and can make it unusable.

      1. Allow the wet filter to dry completely or replace it with a dry filter before using the device for dry vacuuming.

      2. Replace the filter if necessary.

      Cleaning the filter

      Clean the star pleated filter at regular intervals.

      1. Switch off the device.

      2. If dry suction material has been extracted, move the filter cleaning lever back and forth at least 5 times.

      <tasktroubleshooting>

      If this cleaning does not bring any improvement, remove the star pleated filter and wash or replace it (see chapter Care and service).



      </tasktroubleshooting>

      Switching off the device

      1. Switch off the device via the suction turbine power switches.

      2. Pull out the mains plug.

      Each time after use

      1. Remove the accessories.

      2. Remove the accessories and, if necessary, flush with water and allow to dry.

      3. Empty the dirt receptacle (see chapter Emptying the dirt receptacle).

      4. Vacuum the inside and outside of the device and clean with a moist cloth.

      5. Remove the filter for drying if wet suction material has been vacuumed.

      Emptying the dirt receptacle

      WARNING

      Risk of crushing

      When removing or replacing the container, watch for moving parts.

      Note

      The dirt receptacle must be emptied when it is has filled up to approx. 3 cm below the upper edge.

      Regularly check the filling level in the dirt receptacle, since the device does not switch off automatically.

      1. Switch off the device.

      2. Secure the device with the parking brakes.

      3. If dry suction material has been extracted, move the filter cleaning lever back and forth at least 5 times.


      4. Pull the bow handle up.

        The dirt receptacle is unlocked and lowered.

      5. Pull the dirt receptacle out of the device by the bow handle.

      6. Remove the dust collection bag if necessary.

        1. Close the dust collection bag and remove it from the dirt receptacle.

        2. Dispose of the dust collection bag and contents according to the applicable waste disposal regulations.

      7. Empty the dirt receptacle.

        Note

        The dirt receptacle can be lifted by crane at the handle. The maximum load for transport by crane is 50 kg.

        CAUTION

        Exceeding the permissible total weight

        Risk of injury and damage

        Observe the total weight of the dirt receptacle when transporting it by crane.

        Do not overload the receptacle.

        Observe the valid instructions for crane operation.

      8. WARNING

        Improper handling when locking the dirt receptacle

        Risk of crushing

        Under no circumstances should you hold your hands between the dirt receptacle and filter ring or allow them to come close to the lifting mechanism while locking it.

        Lock the dirt receptacle by operating the bow handle with both hands.

      9. Insert the dirt receptacle into the device in reverse order.

      Transport

      CAUTION

      Failure to observe the weight

      Risk of injury and damage

      Be aware of the weight of the device during transportation.

      1. Secure the device against slipping and tipping over when transporting in vehicles.

      Storage

      CAUTION

      Failure to observe the weight

      Risk of injury and damage

      Be aware of the weight of the device during storage.

      1. Store the device indoors only.

      Care and service

      DANGER

      Risk of injury due to inadvertently starting up device and also due to electric shock.

      Switch off the device immediately and unplug the mains plug before performing work.

      Inspection and maintenance work

      Have the device regularly inspected according to the respective national accident prevention regulations. Maintenance work as specified by the manufacturer must be performed by a technically qualified person at the specified regular intervals and in accordance with the applicable regulations and safety requirements. Work on electrical components may only be performed by a qualified electrician. Please contact a KÄRCHER branch office if you have any questions.

      Maintenance intervals / user maintenance

      No periodic maintenance intervals are specified for this device. The following maintenance is to be performed as necessary:

      • Wash the filter.

      • Change the filter.

      • Replace the filter.

      Wash the filter

      ATTENTION

      Use of detergents or bleach

      Damage to the filter.

      Clean the filter with water only. Only fit the filter in the device when it is completely dry.

      The star folded filter can be washed out under running water.

      1. Always flush the star folded filter from the inside to the outside so that no remaining particles impair the filter performance.

      Changing/replacing the filter

      1. Switch off the device.

      2. Pull out the mains plug.

      3. Unlock and remove the suction head.

      4. Unlock and remove the spacer.

      5. Remove the star pleated filter.

      6. Check the sealing ring for damage.

      7. Insert the new star pleated filter:

        1. Pull the new star pleated filter over the filter vibrator on the spacer such that the vibrating elements are aligned centrally in the filter bags.

        2. Place the spacer with star pleated filter and filter vibrator on the filter ring.

        3. Lock the spacer.

      8. Fit and lock the suction head.

      Troubleshooting guide

      DANGER

      Unintentional start-up of the device / electric shock

      Unintentional start-up of the suction motor can cause injuries. Voltage present on electrical parts can cause an electric shock.

      Switch off the device and unplug the mains plug before performing any work on the device.

      Have all checks and work on electrical parts performed by an qualified technician.

      Note

      The device must be switched off immediately in the event of a malfunction. The malfunction must be eliminated before switching the device on again.

      If the malfunction cannot be corrected, the device must be checked by the Customer Service department.

      • Suction turbine does not start up 

      • Suction power decreases 

      • Escaping dust when vacuuming 

      Suction turbine does not start up

      Remedy:

      1. Check the socket and the power supply fuse.

      2. Check the mains cable and the mains plug of the device.

      3. Switch the device on.

      Suction power decreases

      Remedy:

      1. Remove the blockages from the suction nozzle, the suction pipe or the suction hose.

      2. Clean the filter (see chapter Cleaning the filter).

      3. Empty the dirt receptacle (see chapter Emptying the dirt receptacle).

      Escaping dust when vacuuming

      Remedy:

      1. Check the seating of the filter and correct if necessary.

      2. Clean the filter (see chapter Cleaning the filter).

      3. Replace the filter (see chapter Changing/replacing the filter).

      Disposal

      At the end of its service life, the device is to be disposed of in accordance with statutory regulations.

      Warranty

      The warranty conditions issued by our relevant sales company apply in all countries. We shall remedy possible malfunctions on your appliance within the warranty period free of cost, provided that a material or manufacturing flaw is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.

      Further information can be found at: www.kaercher.com/dealersearch

      Further warranty information (if available) can be found in the service area of your local Kärcher website under "Downloads".

      Technical data

      • IVM 60/36-3 

      • IVM 100/36-3 

      IVM 60/36-3

      Electrical connection
      Mains voltage
      220-240 V
      Phase
      1 ~
      Power frequency
      50-60 Hz
      Power
      3150 W
      Protection type
      IPX4
      Protection class
      I*
      Maximum permissible mains grid impedance
      0.195+j0.122 Ω
      Dimensions and weights
      Typical operating weight
      68 kg
      Length x width x height
      1020 x 680 x 1490 mm
      Filter area
      2.24 m2
      Ambient conditions
      Storage temperature
      -10-40 °C
      Device performance data
      Container capacity
      60 l
      Vacuum (with pressure relief valve)
      25.4 kPa
      Air quantity
      3 x 74 l/s
      Suction hose connection
      DN70
      Nominal width of the suction hose
      DN40/50/70
      Filter order number
      6.907-611.0
      Determined values in acc. with EN 60335-2-69
      Hand-arm vibration value
      < 2.5 m/s2
      K uncertainty
      0.2 m/s2
      Sound pressure level LpA
      79 dB(A)
      Uncertainty KpA
      2 dB(A)
      Mains cable
      Type
      H07RN-F 3G1.5 mm2
      Part number
      6.650-035.0
      Cable length
      10 m

      IVM 100/36-3

      Electrical connection
      Mains voltage
      220-240 V
      Phase
      1 ~
      Power frequency
      50-60 Hz
      Power
      3150 W
      Protection type
      IPX4
      Protection class
      I*
      Maximum permissible mains grid impedance
      0.195+j0.122 Ω
      Dimensions and weights
      Typical operating weight
      73 kg
      Length x width x height
      1020 x 680 x 1720 mm
      Filter area
      2.24 m2
      Ambient conditions
      Storage temperature
      -10-40 °C
      Device performance data
      Container capacity
      100 l
      Vacuum (with pressure relief valve)
      25.4 kPa
      Air quantity
      3 x 74 l/s
      Suction hose connection
      DN70
      Nominal width of the suction hose
      DN40/50/70
      Filter order number
      6.907-611.0
      Determined values in acc. with EN 60335-2-69
      Hand-arm vibration value
      < 2.5 m/s2
      K uncertainty
      0.2 m/s2
      Sound pressure level LpA
      79 dB(A)
      Uncertainty KpA
      2 dB(A)
      Mains cable
      Type
      H07RN-F 3G1.5 mm2
      Part number
      6.650-035.0
      Cable length
      10 m

      Declaration of Conformity

      EU Declaration of Conformity

      We hereby declare that the machine described below complies with the relevant basic safety and health requirements in the EU Directives, both in its basic design and construction as well as in the version placed in circulation by us. This declaration is invalidated by any changes made to the machine that are not approved by us.

      Product: Wet/dry vacuum cleaner

      Type: 1.573-xxx

      Type: 9.989-xxx

      Currently applicable EU Directives

      2006/42/EC (+2009/127/EC)

      2014/30/EU

      2011/65/EU

      Harmonised standards used

      EN 60335-1

      EN 60335-2-69

      EN 55014-1: 2017 + A11: 2020

      EN 55014-2: 2015

      EN IEC 61000-3-2: 2019

      EN 61000-3-3: 2013 + A1: 2019

      EN 61000-3-11: 2000

      EN 62233: 2008

      EN IEC 63000: 2018

      National standards used

      -

      The signatories act on behalf of and with the authority of the Executive Board.


      Documentation supervisor:

      A. Haag

      Kärcher Industrial Vacuuming GmbH

      Robert-Bosch-Straße 4-8

      73550 Waldstetten (Germany)

      Ph.: +49 7171 94888-0

      Fax: +49 7171 94888-528

      Waldstetten, 24/04/01

      Declaration of Conformity (UK)

      We hereby declare that the product described below complies with the relevant provisions of the following UK Regulations, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the product is modified without our prior approval.

      Product: Wet/dry vacuum cleaner

      Type: 1.573-xxx

      Type: 9.989-xxx

      Currently applicable UK Regulations

      S.I. 2008/1597 (as amended)

      S.I. 2016/1091 (as amended)

      S.I. 2012/3032 (as amended)

      Designated standards used

      EN 60335-1

      EN 60335-2-69

      EN 55014-1: 2017 + A11: 2020

      EN 55014-2: 2015

      EN IEC 61000-3-2: 2019

      EN 61000-3-3: 2013 + A1: 2019

      EN 61000-3-11: 2000

      EN 62233: 2008

      EN IEC 63000: 2018

      National standards used

      -

      The signatories act on behalf of and with the authority of the Executive Board.


      Documentation supervisor:

      A. Haag

      Kärcher Industrial Vacuuming GmbH

      Robert-Bosch-Straße 4-8

      73550 Waldstetten (Germany)

      Ph.: +49 7171 94888-0

      Fax: +49 7171 94888-528

      Waldstetten, 24/04/01

      <BackPage>

      2-2-HC-A5-GS-awx2508