LogoIVR 9989-3230/-3260/-3280 / 9990-7540/-7550
  • General notes
  • Intended use
  • Environmental protection
  • Accessories and spare parts
  • Scope of delivery
  • Safety devices
    • Hazard levels
    • Safety instructions
    • Behaviour in the event of an emergency
    • Electrical connection
    • Symbols on the device
  • Description of the unit
  • Initial startup
  • Operation
    • Cleaning the dust filter
    • Empty the collection container via the inclined outlet
    • Removing the suction head
  • Ending operation
  • Transport
  • Storage
  • Care and servicing
    • Replacing the filter
    • Replacing the pocket filter
  • Troubleshooting guide
    • The motor (suction turbine) does not start up

    • The suction power decreases

  • Customer Service department
    • The motor (suction turbine) does not start up

    • The suction power decreases

  • Warranty
  • Technical data
  • Declaration of Conformity

       

      99893260 (05/24)

      General notes

      Read these original operating instructions and the enclosed safety instructions before using the device for the first time. Proceed accordingly.

      Keep both books for future reference or for future owners.

      Intended use

      WARNING

      Inhalation of dusts posing a health hazard

      Health hazard

      Never use the appliance to vacuum up dusts which pose a health hazard.

      ATTENTION

      Short-circuit due to high levels of humidity

      Damage to the device

      Only use the device indoors.

      The device is intended for:

      • the vacuuming of non-flammable and non-explosive substances.

      • the vacuuming of dusts and coarse dirt.

      • the vacuuming of moist and liquid substances.

      • industrial usee.g. in storage and production areas

      • commercial use, e.g. in hotels, schools, hospitals, factories, shops, offices, and rental companies.

      Any other use will be regarded as improper use.

      Environmental protection

      The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.

      Electrical and electronic devices contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which - if handled or disposed of incorrectly - can pose a potential danger to human health and the environment. However, these components are required for the correct operation of the device. Devices marked by this symbol are not allowed to be disposed of together with the household rubbish.

      Notes on the content materials (REACH)

      Current information on content materials can be found at: www.kaercher.de/REACH

      Accessories and spare parts

      Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.

      Information on accessories and spare parts can be found at www.kaercher.com.

      Scope of delivery

      Check the contents for completeness when unpacking. If any accessories are missing or in the event of any shipping damage, please notify your dealer.

      Safety devices

      Hazard levels

      DANGER

      Indication of an imminent threat of danger that will lead to severe injuries or even death.

      WARNING

      Indication of a potentially dangerous situation that may lead to severe injuries or even death.

      CAUTION

      Indication of a potentially dangerous situation that may lead to minor injuries.

      ATTENTION

      Indication of a potentially dangerous situation that may lead to damage to property.

      Safety instructions

      WARNING

      The device is not suitable for vacuuming up dusts that are harmful to human health.

      WARNING

      Protect the device from rain. Do not store the device outdoors.

      WARNING

      Every time before use, check whether the equipotential bonding conductors (earthing conductors) are connected.

      CAUTION

      Switch off the device after each use and remove the mains plug.

      ATTENTION

      Only use the device indoors.

      ATTENTION

      Risk of crushing! Wear gloves when removing or installing the suction head, filter inlay or collection container.

      ATTENTION

      Risk of damage! Never vacuum without a filter or with a damaged filter.

      ATTENTION

      Wear safety shoes when operating the device.

      ATTENTION

      Only move the device at walking speed, and to move down a decline, have two workers steady the device as necessary.

      ATTENTION

      Be careful to ensure that there is no dust spillage when replacing accessories.

      Behaviour in the event of an emergency

      DANGER

      Risk of injury and material damage when vacuuming inflammable materials, or in the case of a short-circuit or other electrical faults

      Danger of inhalation of gases hazardous to health, danger of electric shock, danger of burns.

      In the event of an emergency, switch off the device and unplug the mains plug.

      Electrical connection

      The device may only be connected to an electrical connection which has been set up by a qualified electrician as per IEC 60364. For the connection values seeTechnical data and type plate. Use of an extension cable is prohibited.

      DANGER

      Danger of electric shock

      Danger of death

      Avoid damaging the power cables by driving over them or otherwise crushing them, or by jerking them.

      Protect the cables from heat, oil and sharp edges.

      Check the mains connection of the device for damage every time before operation. Do not operate the device using a damaged cable. Have any damaged cables replaced by a qualified electrician.

      Symbols on the device

      Vacuum cleaner labelling
       
      Do not suction up smouldering dust or other sources of ignition.

      Description of the unit


      1. Accessory holder
      2. Suction hose connection
      3. Equipotential bonding cable
      4. Bag filter
      5. Equipotential bonding cable
      6. Power switch
      7. Mains cable
      8. Suction head lock
      9. Equipotential bonding cable
      10. Collection container
      11. Push handle
      12. Steering rollers with parking brake
      13. Angular outlet

      Initial startup

      1. Bring the device into the working position.

      2. If necessary, secure the device using the parking brake.

      3. Ensure that the suction head is fitted correctly.

      4. Insert the suction hose into the suction hose connection.


      5. Plug the desired accessory onto the suction hose.

      Operation

      1. Plug the mains plug into the socket.

      2. Switch on the device using the trigger.


        The switch has multiple level settings:

        0 The device is off.

        1 Motor 1 is switched on.

        2 Motors 1 and 2 are switched on.

      3. Start the vacuuming process.

      Cleaning the dust filter

      Note

      Clean the filter regularly to avoid declining suction power.


      1. Move the filter cleaning handle back and forth several times to clean the filter.

      Empty the collection container via the inclined outlet

      Emptying using manual emptying flap


      1. Switch off the device.

      2. Clean the dust filter.

      3. Move the device to a suitable emptying station.

      4. Engage the roller brakes.

      5. Empty the collection container:

        • Above an emptying station

        1. Pull the hand lever up.

          The manual emptying flap opens.

        • Using a forklift, above a container

        1. Lift the device above the chassis using the forklift.

        2. Lift the device.

        3. Open the manual emptying flap above the container.

        • Using a crane, above a container

        1. Hook the snap hooks of the crane bracket (accessory) into the crane grommets on the device.

        2. Lift the device

        3. Open the manual emptying flap above the container.

        • Into an underfloor conveyor

        1. Open the manual emptying flap above the feed opening.

      6. Push the hand lever down.

        The collection container is closed.

      Removing the suction head

      1. Switch off the device and disconnect from the power supply.

      2. Open the suction head lock.


      3. Remove the suction head and put it to one side.

      Ending operation

      1. Switch off the device using the on/off switch

      2. Empty and clean the collection container.

      3. Remove the accessories and clean and dry them as necessary.

      Transport

      CAUTION

      Failure to observe the weight

      Risk of injury and damage

      Be aware of the weight of the device during transport and storage.

      1. When transporting in vehicles, secure the device against slipping and tipping over according to the applicable guidelines.

      Storage

      CAUTION

      Failure to observe the weight

      Risk of injury and damage

      Be aware of the weight of the device during transport and storage.

      1. Store the device indoors only.

      Care and servicing

      1. Rinse off the device and accessories at regular intervals using a suitable liquid and allow to dry.

      2. Check the bag filter regularly for damage. Replace the bag filter if damaged.

      Replacing the filter


      1. Unscrew the screw plug.

      2. Remove and replace the filter.

      3. Insert the new filter.

        Ensure that the filter is inserted correctly during installation.

      4. Screw in and tighten the screw plug.

      Replacing the pocket filter


      1. Screws
      2. Clamping ring
      3. Pocket filter
      4. Cleaning fixture
      1. Remove the suction head (see chapter Removing the suction head).

      2. Remove the filter unit from the device using the handles and turn it over.


      3. Remove the screws and remove the cleaning fixture.

      4. Loosen the clamping ring screw connection.

      5. Remove the pocket filter.

      6. Dispose of the foam filter.

      7. Insert the new bag filter.

      8. Insert the new foam filter.

      9. Fit the tensioning ring and screw it in place.

      10. Fit the cleaning device and screw it on.

      11. Insert the filter inlay.

        In doing so, make sure the tab on the filter inlay fits into the shaft.


      Troubleshooting guide

      DANGER

      Risk of injury

      Danger of the device unintentionally starting and danger of electric shock

      Switch off the device and unplug the mains plug before performing any work on the device.

      Have all checks and work on electrical parts performed by an qualified technician.

      • The motor (suction turbine) does not start up 

      • The suction power decreases 

      The motor (suction turbine) does not start up

      Cause:

      No electrical voltage present

      Remedy:

      • Check the socket and the power supply fuse.

      • Check the mains cable and the mains plug of the device.

      The suction power decreases

      Cause:

      Nozzle, suction hose or suction pipe clogged.

      Remedy:

      • Check the nozzle, the suction hose and the suction pipe and clean if necessary.

      Cause:

      The filter is dirty.

      Remedy:

      • Clean the filter.

      Customer Service department

      If the malfunction cannot be corrected, the device must be checked by the Customer Service department.

      • The motor (suction turbine) does not start up 

      • The suction power decreases 

      The motor (suction turbine) does not start up

      Cause:

      No electrical voltage present

      Remedy:

      • Check the socket and the power supply fuse.

      • Check the mains cable and the mains plug of the device.

      The suction power decreases

      Cause:

      Nozzle, suction hose or suction pipe clogged.

      Remedy:

      • Check the nozzle, the suction hose and the suction pipe and clean if necessary.

      Cause:

      The filter is dirty.

      Remedy:

      • Clean the filter.

      Warranty

      The warranty conditions issued by our relevant sales company apply in all countries. We shall remedy possible malfunctions on your appliance within the warranty period free of cost, provided that a material or manufacturing flaw is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.

      Further information can be found at: www.kaercher.com/dealersearch

      Further warranty information (if available) can be found in the service area of your local Kärcher website under "Downloads".

      Technical data

        

      Electrical connection
      Mains voltage
      220-240 V
      Phase
      1 ~
      Power frequency
      50-60 Hz
      Degree of protection
      IPX4
      Protection class
      I
      Nominal power
      2400 W
      Power protection (slow-blowing)
      16 A
      Dimensions and weights
      Typical operating weight
      116 kg
      Length x width x height
      950 x 715 x 1640 mm
      Ambient conditions
      Ambient temperature
      +40 °C
      Device performance data
      Tank content
      100 l
      Air quantity
      2 x 74 l/s
      Vacuum
      23 (230) kPa (mbar)
      Nominal width of the suction hose
      DN50
      Determined values in acc. with EN 60335-2-69
      Hand-arm vibration value
      < 2.5 m/s2
      Uncertainty K
      0.2 m/s2
      Sound pressure level LpA
      68 dB(A)
      Uncertainty KpA
      2 dB(A)
      Mains cable
      Mains cable H07BQ-F
      3 x 1.5  mm2
      Part number (EU)
      9.988-393.0
      Cable length
      10 m

      Declaration of Conformity

      EU Declaration of Conformity

      We hereby declare that the machine described below complies with the relevant basic safety and health requirements in the EU Directives, both in its basic design and construction as well as in the version placed in circulation by us. This declaration is invalidated by any changes made to the machine that are not approved by us.

      Product: Dry vacuum cleaner

      Product: Wet/dry vacuum cleaner

      Type: 9.989-xxx

      Currently applicable EU Directives

      2006/42/EC (+2009/127/EC)

      2014/30/EU

      2011/65/EU

      Harmonised standards used

      EN 55014-2: 2015

      EN 55014-1: 2017 + A11: 2020

      EN 60335-1

      EN 60335-2-69

      EN IEC 61000-3-2: 2019

      EN 61000-3-3: 2013 + A1: 2019

      EN 61000-3-11: 2000

      EN 62233: 2008

      EN IEC 63000: 2018

      The signatories act on behalf of and with the authority of the Executive Board.


      Documentation supervisor:

      A. Haag

      Kärcher Industrial Vacuuming GmbH

      Robert-Bosch-Straße 4-8

      73550 Waldstetten (Germany)

      Ph.: +49 7171 94888-0

      Fax: +49 7171 94888-528

      Waldstetten, 2024/04/01

      Declaration of Conformity (UK)

      We hereby declare that the product described below complies with the relevant provisions of the following UK Regulations, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the product is modified without our prior approval.

      Product: Dry vacuum cleaner

      Product: Wet/dry vacuum cleaner

      Type: 9.989-xxx

      Currently applicable UK Regulations

      S.I. 2008/1597 (as amended)

      S.I. 2016/1091 (as amended)

      S.I. 2012/3032 (as amended)

      Designated standards used

      EN 55014-2: 2015

      EN 55014-1: 2017 + A11: 2020

      EN 60335-1

      EN 60335-2-69

      EN IEC 61000-3-2: 2019

      EN 61000-3-3: 2013 + A1: 2019

      EN 61000-3-11: 2000

      EN 62233: 2008

      EN IEC 63000: 2018

      The signatories act on behalf of and with the authority of the Executive Board.


      Documentation supervisor:

      A. Haag

      Kärcher Industrial Vacuuming GmbH

      Robert-Bosch-Straße 4-8

      73550 Waldstetten (Germany)

      Ph.: +49 7171 94888-0

      Fax: +49 7171 94888-528

      Waldstetten, 2024/04/01

      <BackPage>

      2-2-HC-A5-GS-awx2508



      </BackPage>