HD 9/20-4 S, HD 9/20-4 SXA, HD 10/21-4 SHD 10/21-4 SXA, HD 10/25-4 S, HD 10/25-4 SXAHD 13/18-4 S, HD 13/18-4 SXA
59692610 (06/23)
59692610 (06/23)
Read these original operating instructions and the enclosed safety instructions before using the device for the first time. Proceed accordingly.
Keep both books for future reference or for future owners.
Use this high-pressure cleaner only for the following types of work:
Cleaning with the high-pressure jet without detergent (e.g. façades, terraces, garden machines)
Cleaning with the low-pressure jet and detergent with the cup foam lance available as an accessory (e.g. for cleaning machines, vehicles, buildings, tools)
We recommend using a rotary nozzle as a special accessory for stubborn soiling.
A rotary nozzle is included in the scope of delivery of the HD...Plus variant.
The device can be operated with Servo Control accessories.
Dirty water
Premature wear and tear or deposits in the device
Supply the device using only clean water, or recycled water that does not exceed the specified limit values.
The following limit values apply to the water supply:
pH value: 6.5-9.5
Electrical conductivity: Conductivity of fresh water + 1200 µS/cm, maximum conductivity 2000 µS/cm
Settleable particles (sample volume 1 l, settling time 30 minutes): < 0.5 mg/l
Filterable particles: < 50 mg/l, no abrasive substances
Hydrocarbons: < 20 mg/l
Chloride: < 300 mg/l
Sulphate: < 240 mg/l
Calcium: < 200 mg/l
Total hardness: < 28 °dH, < 50° TH, < 500 ppm (mg CaCO3/l)
Iron: < 0.5 mg/l
Manganese: < 0.05 mg/l
Copper: < 2 mg/l
Active chloride: < 0.3 mg/l
Free of unpleasant odours
The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.
Electrical and electronic devices contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which - if handled or disposed of incorrectly - can pose a potential danger to human health and the environment. However, these components are required for the correct operation of the device. Devices marked by this symbol are not allowed to be disposed of together with the household rubbish.
Notes on the content materials (REACH)Current information on content materials can be found at: www.kaercher.de/REACH
Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.
Information on accessories and spare parts can be found at www.kaercher.com.
Check the contents for completeness when unpacking. If any accessories are missing or in the event of any shipping damage, please notify your dealer.
It is essential that you read the safety instructions 5.951-949.0 before initial startup.
Observe the national regulations for liquid jet cleaners.
Observe the national accident prevention regulations. Liquid jet cleaners must be tested regularly. The test result must be recorded in writing.
Do not modify the device or accessories.
The device may not be connected to the public drinking water network.
The high-pressure jet must not be directed at persons, animals, live electrical equipment or at the device itself. Protect the device from frost.
Missing or modified safety devices
Safety devices are provided for your own protection.
Never modify or bypass safety devices.
The safety devices are set and sealed by the manufacturer. Adjustments are performed only by customer service.
When the water quantity is reduced via the pressure/quantity control on the trigger gun, the overflow valve opens and part of the water flows back to the suction side of the pump.
When the trigger on the high-pressure gun is release, the pressure switch switches off the high-pressure pump and the high-pressure jet stops.
The pump switches on again when the trigger is pulled.
See graphics page
* Only with HD 10/25 and HD 13/18
** Only with S version
*** Only with SXA version
**** Only with Plus version
Unscrew the fastening screw on the device hood.
Remove the device hood.
Cut off the tip of the oil tank cap so that there is a small opening.
Fasten the device hood.
Place the device on a level surface.
The oil level must be between the "MIN" and "MAX" marks on the oil level indicator.
If necessary, the cable holders can be rotated.
Unscrew the screw by about 4 turns.
Pull out the cable holder and turn it to the desired position.
Push the cable holder towards the device so that it engages in the latch.
Tighten the screw.
The EASY!Lock system connects components quickly and safely via a single turn of the quick-release thread.
Plug the high-pressure nozzle onto the spray lance.
Fit the union nut and hand-tighten (EASY!Lock).
Connect the spray lance to the high-pressure gun and hand-tighten (EASY!Lock).
For devices without a hose reel:
Connect the high-pressure hose to the high-pressure gun and high-pressure connection of the device and tighten hand-tight (EASY!Lock).
For devices with a hose reel:
Connect the high-pressure hose to the high-pressure gun and hand-tighten (EASY!Lock).
Risk of injury from electric shock
Use a plug to connect the device to the mains grid. Permanent connection to the mains grid is prohibited. The plug is used for mains isolation.
Only connect the device to an AC power source.
Use an extension cable with sufficient diameter (see "Technical data").
Unwind the extension cable completely from the cable drum.
Unwind the mains cable and place on the ground.
Plug the mains plug into the socket.
Return flow of dirty water into the drinking water network
Health risk
Observe the regulations of your water supply company.
According to applicable regulations, the device must never be used with the drinking water network without a system separator. Use a system separator from KÄRCHER or a system separator as per EN 12729 Type BA. Water that has flowed through a system separator is classified as undrinkable. Always connect the system separator to the water supply and never directly to the water connection on the device.
Check the supply pressure, supply temperature and supply volume of the water supply (see chapter Technical data).
Connect the system separator to the water connection of the device using a water supply hose (for the requirements placed on the water supply hose see chapter Technical data).
Open the water inlet.
Screw the suction hose with filter onto the water connection (for the order number see chapter Technical data).
Vent the device (see chapter Vent the device).
Unscrew the high-pressure nozzle from the spray lance.
Allow the device to run until the escaping water is free of air bubbles.
In the case of venting problems, allow the device to run for 10 seconds and then switch it off. Repeat the procedure several times.
Switch off the device.
Screw the high-pressure nozzle onto the spray lance.
Risk of injury
The high-pressure jet can cause injuries.
Never fasten the trigger and safety lever in the actuated position.
Do not use the high-pressure gun when the safety lever is damaged.
If the safety lever is defective, contact the Customer Service.
Push the safety latch of the high-pressure gun forwards every time before starting work with the device.
Never operate the device without the spray lance installed. Check the spray lance for tight fit. The spray lance must be hand-tight.
Hold the high-pressure gun and spray lance with both hands.
Check that the device, accessories, supply lines and connections for damage. Only use the device when in a correct operating condition.
The device is equipped with an automatic hose reel.
Pull out the hose.
The hose reel locks during the release.
Risk of injury
If the high-pressure hose is released during rewinding, it can make uncontrolled movements and bump and fling objects around.
Hold the high-pressure hose firmly and guide the hose during the rewinding process.
Do not reach into the hose reel.
Pull out the hose slightly and then release it.
The hose reel coils the hose automatically.
Regulate the reeling speed during coiling by guiding the hose.
Actuate the safety lever and trigger.
The high-pressure gun opens.
Release the safety lever and trigger.
The high-pressure gun closes.
The device is equipped with a pressure switch. The motor only starts up when the high-pressure gun is open.
For devices with a hose reel: Completely unroll the high-pressure hose from the hose reel.
Set the trigger to "I".
For HD 10/25...and 13/18...: Indicator light lights up green.
Unlock the high-pressure gun by pushing the high-pressure gun safety latch to the rear.
Open the high-pressure gun.
Risk of injury
The water jet coming out of the pressure control/flow control can cause injuries.
Make sure that the connection between the pressure control/flow control and the steel pipe does not come loose.
Set the working pressure and water quantity by turning the pressure control/flow control.
At the lowest flow rate, the waste heat from the motor heats the water to approx. 15 °C.
Incorrect handling of detergents
Health risk
Adhere to the safety instructions stated on the detergent packaging.
Unsuitable detergents
Damage to the device and the objects to be cleaned
Use only detergents approved by KÄRCHER.
Observe the dosing recommendations and notes provided with the detergent.
Use detergents sparingly to help conserve the environment.
KÄRCHER detergents ensure fault-free operation. Ask us for a consultation, request our catalogue or our detergent information sheets.
A cup foam lance (optional)is needed for operating with detergent.
Unscrew the container.
Plug the desired gate into the suction hose.
Fill the detergent into the container.
Screw the container onto the foam nozzle.
Disconnect the spray lance from the high-pressure gun.
Connect the cup foam lance to the high-pressure gun and hand-tighten.
Start up the high-pressure cleaner.
Spray the detergent sparingly on the dry surface and let it work for a while (do not let it dry).
Rinse off the loosened dirt with the high-pressure jet.
The cup foam lance must be flushed after use to prevent the formation of detergent deposits.
Unscrew the container.
Pour the remaining detergent back into the original packaging.
Fill the container with clear water.
Screw the container onto the cup foam lance nozzle.
Operate the cup foam lance for approx. 1 minute to flush the detergent residue.
Empty the container.
Close the high-pressure gun.
The device switches off.
Push the safety latch forwards.
The high-pressure gun is secured.
Push the safety latch backwards.
The high-pressure gun is unlocked.
Open the high-pressure gun.
The device switches on.
Only the versions HD 10/25... and HD 13/18... are equipped with this function.
Within the standby time, the device starts when the high-pressure gun is opened. Indicator light lights up green.
If the high-pressure gun remains closed for 30 minutes, the standby time ends. Indicator light flashes green.
Set the power switch to "0".
Wait for a few seconds.
Set the trigger to "I".
The device can be switched to continuous operation by the Customer Service.
Danger of scalding
Residual water contained in the switched-off device may heat up. When removing the hose from the water inlet, the heated water may splash out and cause scalding.
Do not remove the water supply hose until the device has cooled down.
Close the water inlet.
Open the high-pressure gun.
Set the power switch to "I/ON" and allow the device to run for 5 to 10 seconds.
Close the high-pressure gun.
Set the power switch to "0".
Pull the mains plug out of the socket only when your hands are dry.
Remove the water inlet.
Open the high-pressure gun until the device is completely depressurised.
Push the safety latch forwards.
The high-pressure gun is secured.
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during transport and storage.
Improper transportation
Risk of damage
Protect the trigger of the high-pressure gun from damage.
Transporting the device in vehicles: Secure the device in accordance with the respectively applicable guidelines to prevent it from slipping or overturning.
Transporting the device over longer distances: Pull or push the device using the push handle.
Risk of injury
A device improperly transported with a crane can fall down and cause injuries.
Observe the local accident prevention regulations and the safety instructions.
The device may only be transported with a crane by persons instructed in the operation of the crane.
Check the lifting gear for damage before each crane transport.
Check the device for damage before each crane transport.
Lift the device only as described at the end of the chapter.
Do not attach the lifting gear to the push handle of the device.
Do not use slinging chains.
Secure the lifting gear against unintentional unhooking of the load.
Remove the spray lance with high-pressure gun, nozzles, surface cleaner and other loose objects before transporting by crane.
Do not transport any objects on the device during the lifting operation.
Do not stand under the suspended load.
Ensure that no persons are in the hazard zones of the crane.
Do not leave the device handing unattended on the crane.
Attach the lifting gear to the device.
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during transport and storage.
Store the device indoors only.
Fit the spray lance with high-pressure gun into the nozzle holder and latch into position in the spray lance holder.
Wrap the mains cable around the cable holder and secure it with the cable clip.
Wind up the high-pressure hose:
Version S: Wind up the high-pressure hose, place it on the hose rack and secure it with the rubber tensioner.
SXA version: Wind the high-pressure hose onto the hose reel.
Frost destroys the device if it is not completely drained of water.
Store the device in a frost-free location.
If frost-free storage is not possible:
Drain the water.
Pump commonly available anti-freeze through the device.
Allow the device for run for a maximum of 1 minute until the pump and lines are empty.
Use commonly available, Glycol-based vehicle anti-freeze. Observe the handling instructions of the anti-freeze manufacturer.
Inadvertently starting up device
Risk of injury, electric shock
Switch off the device immediately and unplug the mains plug before performing work.
Old oil may only be disposed of at designated collection points. Please dispose of any old oil at these locations. Polluting the environment with old oil is punishable by law.
You can agree on regular safety inspections or close a maintenance contract with your dealer. Please seek advice on this.
Check the mains cable for damage.
Have a damaged cable replaced immediately by the authorised Customer Service or a qualified electrician.
Check the high-pressure hose for damage.
Immediately replace a damaged high-pressure hose.
Check the device for leaks.
3 drops of water per minute are permissible. Contact Customer Service in the case of more serious leaks.
Check the oil level. Contact Customer Service immediately if the oil is milky (water in oil).
Clean the fine filter.
Unscrew the union nut.
Pull out the connection nozzle.
Pull the fine filter out of the filter housing by the folding handle.
Rinse the fine filter with clear water or blow it out with compressed air.
Check the O-ring on the fine filter and replace if necessary.
Insert the fine filter into the filter housing.
Check the O-ring on the connection nozzle and replace if necessary.
Attach the connection nozzle.
Screw on the union nut and hand-tighten.
Have the device serviced by Customer Service.
Change the oil in the high-pressure pump:
Tilt the device to the rear and set it down.
Place a catch pan underneath the oil drain screw to collect the engine oil.
Pull the clip out downwards.
Pull out the plug.
Drain the oil into a suitable collection container.
Check the O-ring on the plug, replace if necessary.
Insert the plug and secure it with the clip.
Wipe off any oil remaining in the drainage channel.
Erect the device.
Unscrew the fastening screw on the device hood.
Remove the device hood.
Remove the oil tank cap.
Fill in new oil slowly so that air bubbles can escape. See the "Technical data" section for the oil volume and type.
Replace the oil tank cap.
Replace and secure the device hood.
Operate the device for 5 minutes and then check the oil level again.
Risk of injury
The hose reel may turn very fast unexpectedly if it is released.
Carefully follow the steps below and secure the hose reel as described.
Only high-pressure hoses in the "Ultra Guard" version are suitable for this device.
Lift off the cover on the hose reel with a screwdriver.
Completely unroll the high-pressure hose from the hose reel.
Insert a 10 mm Allen key through the hexagonal opening in the casing. Insert the key until the hose reel is blocked.
Unscrew the 2 screws.
Remove the hose stopper from the high-pressure hose.
Pull out the locking hook.
Pull the high-pressure hose out of the hose connection.
Insert the new high-pressure hose through the hose guide rollers and insert it into the hose connection. Observe the direction of rotation of the hose reel.
Insert the locking hook into the hose connection.
Check that all washers are behind the locking hook.
Fit the hose stopper to the other end of the high-pressure hose. Distance to the end of the hose about 1 m (to the high-pressure gun).
Connect the device to the water supply and power supply, put it into operation and check the connection for leaks.
Tension the hose and keep it tensioned. Pull out the Allen key while the hose is taut.
Unlock the hose reel by pulling on the high-pressure hose and let the high-pressure hose slowly roll up. Control the reeling speed by holding the hose.
Replace the cover.
Inadvertently starting up device, touching live components
Risk of injury, electric shock
Switch off the device before performing any work on the device.
Remove the mains plug.
Have all checks and work on electrical parts performed by a qualified electrician.
In case of any malfunctions not mentioned in this chapter, contact the authorised Customer Service.
This function is only available with HD 10/25... and HD 13/18...
The indicator light indicates operating states (green) and malfunctions (red).
Continuous green light
Cause:
The device is ready for operation.
Flashes green once
Cause:
Standby mode has expired after 30 minutes of continuous operation and the device is switched off (safety if the high-pressure hose has burst).
To restart the standby time:
Remedy:
Set the power switch to "0".
Wait for a few seconds.
Set the trigger to "I".
Flashes red once
Cause:
The high-pressure side is leaking.
Remedy:
Check the high-pressure hose, hose connections and high-pressure gun for leaks.
Flashes red twice
Cause:
The motor is too hot.
Remedy:
Set the power switch to "0".
Allow the device to cool down.
Set the trigger to "I".
If this fault occurs repeatedly, check the nozzle, water supply temperature, ambient temperature and mains voltage.
Flashes red three times
Cause:
A fault has occurred in the voltage supply.
Remedy:
Check the power supply and the mains power supply circuit breaker.
Cause:
The power consumption is too high.
Remedy:
Consult the Customer Service.
The device cannot be started.
Remedy:
When the indicator light flashes green:
Set the power switch to "0".
Set the trigger to "I".
Allow the motor to cool down:
Set the power switch to "0".
Allow the device to cool down.
Set the trigger to "I".
Check the mains cable for damage.
Check the mains voltage.
Contact Customer Service in the case of electrical faults.
Device does not reach required pressure
Remedy:
Check that the high-pressure nozzle is the right size (see chapter "Technical data").
Clean or replace the nozzle.
Vent the device (see chapter "Venting the water connection/device.").
Clean the fine filter, replace if necessary (see chapter "Care and Maintenance/Weekly").
Check the water supply volume (compare with the required volume specified in the "Technical data" chapter).
Contact Customer Service if necessary.
The pump is leaking.
Up to 3 drops of water per minute are permissible.
Remedy:
In case of more serious leaks, have the device checked by Customer Service.
The pump knocks
Remedy:
Check the water supply volume (compare with the required volume specified in the "Technical data" chapter).
Vent the device (see chapter "Venting the water connection/device.").
Clean the fine filter, replace if necessary (see chapter "Care and Maintenance/Weekly").
Contact Customer Service if necessary.
The detergent dosing volume is too low
Remedy:
Check that the cup foam lance used matches the flow rate of the device.
Refill the cup of the cup foam lance.
Plug a larger gate onto the suction hose.
Check the suction hose and cup foam nozzle for detergent deposits. Remove deposits using lukewarm water.
Contact Customer Service if necessary.
The foam formation is too low
Remedy:
Check that the cup foam lance used matches the flow rate of the device.
Check the suction hose and cup foam lance for detergent deposits. Remove deposits using lukewarm water.
Contact Customer Service if necessary.
Set the power switch to "0".
Wait for a few seconds.
Set the trigger to "I".
Continuous green light
Cause:
The device is ready for operation.
Flashes green once
Cause:
Standby mode has expired after 30 minutes of continuous operation and the device is switched off (safety if the high-pressure hose has burst).
To restart the standby time:
Remedy:
Set the power switch to "0".
Wait for a few seconds.
Set the trigger to "I".
Flashes red once
Cause:
The high-pressure side is leaking.
Remedy:
Check the high-pressure hose, hose connections and high-pressure gun for leaks.
Flashes red twice
Cause:
The motor is too hot.
Remedy:
Set the power switch to "0".
Allow the device to cool down.
Set the trigger to "I".
If this fault occurs repeatedly, check the nozzle, water supply temperature, ambient temperature and mains voltage.
Flashes red three times
Cause:
A fault has occurred in the voltage supply.
Remedy:
Check the power supply and the mains power supply circuit breaker.
Cause:
The power consumption is too high.
Remedy:
Consult the Customer Service.
Continuous green light
Cause:
The device is ready for operation.
Flashes green once
Cause:
Standby mode has expired after 30 minutes of continuous operation and the device is switched off (safety if the high-pressure hose has burst).
To restart the standby time:
Remedy:
Set the power switch to "0".
Wait for a few seconds.
Set the trigger to "I".
Flashes red once
Cause:
The high-pressure side is leaking.
Remedy:
Check the high-pressure hose, hose connections and high-pressure gun for leaks.
Flashes red twice
Cause:
The motor is too hot.
Remedy:
Set the power switch to "0".
Allow the device to cool down.
Set the trigger to "I".
If this fault occurs repeatedly, check the nozzle, water supply temperature, ambient temperature and mains voltage.
Flashes red three times
Cause:
A fault has occurred in the voltage supply.
Remedy:
Check the power supply and the mains power supply circuit breaker.
Cause:
The power consumption is too high.
Remedy:
Consult the Customer Service.
Continuous green light
Cause:
The device is ready for operation.
Flashes green once
Cause:
Standby mode has expired after 30 minutes of continuous operation and the device is switched off (safety if the high-pressure hose has burst).
To restart the standby time:
Remedy:
Set the power switch to "0".
Wait for a few seconds.
Set the trigger to "I".
Flashes red once
Cause:
The high-pressure side is leaking.
Remedy:
Check the high-pressure hose, hose connections and high-pressure gun for leaks.
Flashes red twice
Cause:
The motor is too hot.
Remedy:
Set the power switch to "0".
Allow the device to cool down.
Set the trigger to "I".
If this fault occurs repeatedly, check the nozzle, water supply temperature, ambient temperature and mains voltage.
Flashes red three times
Cause:
A fault has occurred in the voltage supply.
Remedy:
Check the power supply and the mains power supply circuit breaker.
Cause:
The power consumption is too high.
Remedy:
Consult the Customer Service.
The device cannot be started.
Remedy:
When the indicator light flashes green:
Set the power switch to "0".
Set the trigger to "I".
Allow the motor to cool down:
Set the power switch to "0".
Allow the device to cool down.
Set the trigger to "I".
Check the mains cable for damage.
Check the mains voltage.
Contact Customer Service in the case of electrical faults.
Device does not reach required pressure
Remedy:
Check that the high-pressure nozzle is the right size (see chapter "Technical data").
Clean or replace the nozzle.
Vent the device (see chapter "Venting the water connection/device.").
Clean the fine filter, replace if necessary (see chapter "Care and Maintenance/Weekly").
Check the water supply volume (compare with the required volume specified in the "Technical data" chapter).
Contact Customer Service if necessary.
The pump is leaking.
Up to 3 drops of water per minute are permissible.
Remedy:
In case of more serious leaks, have the device checked by Customer Service.
The pump knocks
Remedy:
Check the water supply volume (compare with the required volume specified in the "Technical data" chapter).
Vent the device (see chapter "Venting the water connection/device.").
Clean the fine filter, replace if necessary (see chapter "Care and Maintenance/Weekly").
Contact Customer Service if necessary.
The detergent dosing volume is too low
Remedy:
Check that the cup foam lance used matches the flow rate of the device.
Refill the cup of the cup foam lance.
Plug a larger gate onto the suction hose.
Check the suction hose and cup foam nozzle for detergent deposits. Remove deposits using lukewarm water.
Contact Customer Service if necessary.
The foam formation is too low
Remedy:
Check that the cup foam lance used matches the flow rate of the device.
Check the suction hose and cup foam lance for detergent deposits. Remove deposits using lukewarm water.
Contact Customer Service if necessary.
The warranty conditions issued by our sales company responsible apply in all countries. We shall remedy possible malfunctions on your device within the warranty period free of cost, provided that a material or manufacturing defect is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.
You can find more detailed information at: www.kaercher.com/dealersearch
Country variant | |
Country | EU |
Electrical connection | |
Voltage | 400 V |
Phase | 3 ~ |
Frequency | 50 Hz |
Maximum permissible mains grid impedance | - Ω |
Power rating | 7,0 kW |
Degree of protection | IPX5 |
Power protection (slow-blow, char. C) | 16 A |
Extension cable, 10 m | 2,5 mm2 |
Extension cable, 30 m | 4 mm2 |
Water connection | |
Feed pressure (max.) | 1 MPa |
Input temperature (max.) | 60 °C |
Input amount (min.) | 1100 l/h |
Suction height (max.) | 0,5 m |
Minimum water supply hose length | 7,5 m |
Minimum water supply hose diameter | 1 in |
Suction filter order number | 4.730-012.0 |
Device performance data | |
Nozzle size of standard nozzle | 047 |
Water operating pressure with standard nozzle | 20 MPa |
Operating pressure (max.) | 25 MPa |
Water flow rate | 15 l/min |
High-pressure gun recoil force | 48 N |
Dimensions and weights | |
Typical operating weight | 62,4 kg |
Length | 607 mm |
Width | 518 mm |
Height | 1063 mm |
Oil volume | 1,0 l |
Oil type | SAE 90 Type |
Determined values in acc. with EN 60335-2-79 | |
Hand-arm vibration value | 3,6 m/s2 |
Uncertainty K | 0,9 m/s2 |
Sound pressure level LpA | 72 dB(A) |
Uncertainty KpA | 3 dB(A) |
Measured sound power level LWA | 91 dB(A) |
Guaranteed sound power level LWA,d | 93 dB(A) |
Country variant | |
Country | EU |
Electrical connection | |
Voltage | 400 V |
Phase | 3 ~ |
Frequency | 50 Hz |
Maximum permissible mains grid impedance | - Ω |
Power rating | 7,0 kW |
Degree of protection | IPX5 |
Power protection (slow-blow, char. C) | 16 A |
Extension cable, 10 m | 2,5 mm2 |
Extension cable, 30 m | 4 mm2 |
Water connection | |
Feed pressure (max.) | 1 MPa |
Input temperature (max.) | 60 °C |
Input amount (min.) | 1100 l/h |
Suction height (max.) | 0,5 m |
Minimum water supply hose length | 7,5 m |
Minimum water supply hose diameter | 1 in |
Suction filter order number | 4.730-012.0 |
Device performance data | |
Nozzle size of standard nozzle | 047 |
Water operating pressure with standard nozzle | 20 MPa |
Operating pressure (max.) | 25 MPa |
Water flow rate | 15 l/min |
High-pressure gun recoil force | 49 N |
Dimensions and weights | |
Typical operating weight | 74 kg |
Length | 607 mm |
Width | 518 mm |
Height | 1063 mm |
Oil volume | 1,0 l |
Oil type | SAE 90 Type |
Determined values in acc. with EN 60335-2-79 | |
Hand-arm vibration value | 3,7 m/s2 |
Uncertainty K | 0,9 m/s2 |
Sound pressure level LpA | 72 dB(A) |
Uncertainty KpA | 3 dB(A) |
Measured sound power level LWA | 91 dB(A) |
Guaranteed sound power level LWA,d | 93 dB(A) |
Country variant | |
Country | EU |
Electrical connection | |
Voltage | 400 V |
Phase | 3 ~ |
Frequency | 50 Hz |
Maximum permissible mains grid impedance | - Ω |
Power rating | 8,0 kW |
Degree of protection | IPX5 |
Power protection (slow-blow, char. C) | 16 A |
Extension cable, 10 m | 2,5 mm2 |
Extension cable, 30 m | 4 mm2 |
Water connection | |
Feed pressure (max.) | 1 MPa |
Input temperature (max.) | 60 °C |
Input amount (min.) | 1200 l/h |
Suction height (max.) | 0,5 m |
Minimum water supply hose length | 7,5 m |
Minimum water supply hose diameter | 1 in |
Suction filter order number | 4.730-012.0 |
Device performance data | |
Nozzle size of standard nozzle | 050 |
Water operating pressure with standard nozzle | 23 MPa |
Operating pressure (max.) | 25 MPa |
Water flow rate | 16,7 l/min |
High-pressure gun recoil force | 56 N |
Dimensions and weights | |
Typical operating weight | 63,4 kg |
Length | 607 mm |
Width | 518 mm |
Height | 1063 mm |
Oil volume | 1,0 l |
Oil type | SAE 90 Type |
Determined values in acc. with EN 60335-2-79 | |
Hand-arm vibration value | 4,6 m/s2 |
Uncertainty K | 1,0 m/s2 |
Sound pressure level LpA | 72 dB(A) |
Uncertainty KpA | 3 dB(A) |
Measured sound power level LWA | 91 dB(A) |
Guaranteed sound power level LWA,d | 93 dB(A) |
Country variant | |
Country | EU |
Electrical connection | |
Voltage | 400 V |
Phase | 3 ~ |
Frequency | 50 Hz |
Maximum permissible mains grid impedance | - Ω |
Power rating | 8,0 kW |
Degree of protection | IPX5 |
Power protection (slow-blow, char. C) | 16 A |
Extension cable, 10 m | 2,5 mm2 |
Extension cable, 30 m | 4 mm2 |
Water connection | |
Feed pressure (max.) | 1 MPa |
Input temperature (max.) | 60 °C |
Input amount (min.) | 1200 l/h |
Suction height (max.) | 0,5 m |
Minimum water supply hose length | 7,5 m |
Minimum water supply hose diameter | 1 in |
Suction filter order number | 4.730-012.0 |
Device performance data | |
Nozzle size of standard nozzle | 050 |
Water operating pressure with standard nozzle | 23 MPa |
Operating pressure (max.) | 25 MPa |
Water flow rate | 16,7 l/min |
High-pressure gun recoil force | 56 N |
Dimensions and weights | |
Typical operating weight | 75 kg |
Length | 607 mm |
Width | 518 mm |
Height | 1063 mm |
Oil volume | 1,0 l |
Oil type | SAE 90 Type |
Determined values in acc. with EN 60335-2-79 | |
Hand-arm vibration value | 4,4 m/s2 |
Uncertainty K | 0,9 m/s2 |
Sound pressure level LpA | 75 dB(A) |
Uncertainty KpA | 3 dB(A) |
Measured sound power level LWA | 91 dB(A) |
Guaranteed sound power level LWA,d | 93 dB(A) |
Country variant | |
Country | KAP |
Electrical connection | |
Voltage | 380 V |
Phase | 3 ~ |
Frequency | 50 Hz |
Maximum permissible mains grid impedance | - Ω |
Power rating | 8 kW |
Degree of protection | IPX5 |
Power protection (slow-blow, char. C) | 16 A |
Extension cable, 10 m | 2,5 mm2 |
Extension cable, 30 m | 4 mm2 |
Water connection | |
Feed pressure (max.) | 1 MPa |
Input temperature (max.) | 60 °C |
Input amount (min.) | 1200 l/h |
Suction height (max.) | 0,5 m |
Minimum water supply hose length | 7,5 m |
Minimum water supply hose diameter | 1 in |
Suction filter order number | 4.730-012.0 |
Device performance data | |
Nozzle size of standard nozzle | 050 |
Water operating pressure with standard nozzle | 21 MPa |
Operating pressure (max.) | 25 MPa |
Water flow rate | 16,67 l/min |
High-pressure gun recoil force | 56 N |
Dimensions and weights | |
Typical operating weight | 63,4 kg |
Length | 607 mm |
Width | 518 mm |
Height | 1063 mm |
Oil volume | 1 l |
Oil type | SAE 90 Type |
Determined values in acc. with EN 60335-2-79 | |
Hand-arm vibration value | 4,6 m/s2 |
Uncertainty K | 1 m/s2 |
Sound pressure level LpA | 70 dB(A) |
Uncertainty KpA | 3 dB(A) |
Measured sound power level LWA | 91 dB(A) |
Guaranteed sound power level LWA,d | 93 dB(A) |
Country variant | |
Country | EU |
Electrical connection | |
Voltage | 400 V |
Phase | 3 ~ |
Frequency | 50 Hz |
Maximum permissible mains grid impedance | 0.0452 + j0.0283 Ω |
Power rating | 8,8 kW |
Degree of protection | IPX5 |
Power protection (slow-blow, char. C) | 16 A |
Extension cable, 10 m | 2,5 mm2 |
Extension cable, 30 m | 4 mm2 |
Water connection | |
Feed pressure (max.) | 1 MPa |
Input temperature (max.) | 60 °C |
Input amount (min.) | 1200 l/h |
Suction height (max.) | 0,5 m |
Minimum water supply hose length | 7,5 m |
Minimum water supply hose diameter | 1 in |
Suction filter order number | 4.730-012.0 |
Device performance data | |
Nozzle size of standard nozzle | 047 |
Water operating pressure with standard nozzle | 25 MPa |
Operating pressure (max.) | 28 MPa |
Water flow rate | 16,67 l/min |
High-pressure gun recoil force | 62 N |
Dimensions and weights | |
Typical operating weight | 67 kg |
Length | 607 mm |
Width | 518 mm |
Height | 1063 mm |
Oil volume | 1,0 l |
Oil type | SAE 90 Type |
Determined values in acc. with EN 60335-2-79 | |
Hand-arm vibration value | 4,7 m/s2 |
Uncertainty K | 1 m/s2 |
Sound pressure level LpA | 74 dB(A) |
Uncertainty KpA | 3 dB(A) |
Measured sound power level LWA | 91 dB(A) |
Guaranteed sound power level LWA,d | 93 dB(A) |
Country variant | |
Country | EU |
Electrical connection | |
Voltage | 400 V |
Phase | 3 ~ |
Frequency | 50 Hz |
Maximum permissible mains grid impedance | 0.0452+j0.0283 Ω |
Power rating | 8,8 kW |
Degree of protection | IPX5 |
Power protection (slow-blow, char. C) | 16 A |
Extension cable, 10 m | 2,5 mm2 |
Extension cable, 30 m | 4 mm2 |
Water connection | |
Feed pressure (max.) | 1 MPa |
Input temperature (max.) | 60 °C |
Input amount (min.) | 1200 l/h |
Suction height (max.) | 0,5 m |
Minimum water supply hose length | 7,5 m |
Minimum water supply hose diameter | 1 in |
Suction filter order number | 4.730-012.0 |
Device performance data | |
Nozzle size of standard nozzle | 047 |
Water operating pressure with standard nozzle | 25 MPa |
Operating pressure (max.) | 28 MPa |
Water flow rate | 16,67 l/min |
High-pressure gun recoil force | 62 N |
Dimensions and weights | |
Typical operating weight | 78,6 kg |
Length | 607 mm |
Width | 518 mm |
Height | 1063 mm |
Oil volume | 1,0 l |
Oil type | SAE 90 Type |
Determined values in acc. with EN 60335-2-79 | |
Hand-arm vibration value | 4,7 m/s2 |
Uncertainty K | 1 m/s2 |
Sound pressure level LpA | 76 dB(A) |
Uncertainty KpA | 3 dB(A) |
Measured sound power level LWA | 91 dB(A) |
Guaranteed sound power level LWA,d | 93 dB(A) |
Country variant | |
Country | KAP |
Electrical connection | |
Voltage | 220 V |
Phase | 3 ~ |
Frequency | 60 Hz |
Maximum permissible mains grid impedance | 0.0452 + j0.0283 Ω |
Power rating | 7,5 kW |
Degree of protection | IPX5 |
Power protection (slow-blow, char. C) | 25 A |
Extension cable, 10 m | 2,5 mm2 |
Extension cable, 30 m | 4 mm2 |
Water connection | |
Feed pressure (max.) | 1 MPa |
Input temperature (max.) | 60 °C |
Input amount (min.) | 1200 l/h |
Suction height (max.) | 0,5 m |
Minimum water supply hose length | 7,5 m |
Minimum water supply hose diameter | 1 in |
Suction filter order number | 4.730-012.0 |
Device performance data | |
Nozzle size of standard nozzle | 055 |
Water operating pressure with standard nozzle | 19 MPa |
Operating pressure (max.) | 22 MPa |
Water flow rate | 16,67 l/min |
High-pressure gun recoil force | 54 N |
Dimensions and weights | |
Typical operating weight | 67,0 kg |
Length | 607 mm |
Width | 518 mm |
Height | 1063 mm |
Oil volume | 1 l |
Oil type | SAE 90 Type |
Determined values in acc. with EN 60335-2-79 | |
Hand-arm vibration value | 6,1 m/s2 |
Uncertainty K | 1,5 m/s2 |
Sound pressure level LpA | 75 dB(A) |
Uncertainty KpA | 3 dB(A) |
Measured sound power level LWA | 91 dB(A) |
Guaranteed sound power level LWA,d | 93 dB(A) |
Country variant | |
Country | KAP |
Electrical connection | |
Voltage | 440-460 V |
Phase | 3 ~ |
Frequency | 60 Hz |
Maximum permissible mains grid impedance | 0.0452 + j0.0283 Ω |
Power rating | 8 kW |
Degree of protection | IPX5 |
Power protection (slow-blow, char. C) | 16 A |
Extension cable, 10 m | 2,5 mm2 |
Extension cable, 30 m | 4 mm2 |
Water connection | |
Feed pressure (max.) | 1 MPa |
Input temperature (max.) | 60 °C |
Input amount (min.) | 1200 l/h |
Suction height (max.) | 0,5 m |
Minimum water supply hose length | 7,5 m |
Minimum water supply hose diameter | 1 in |
Suction filter order number | 4.730-012.0 |
Device performance data | |
Nozzle size of standard nozzle | 050 |
Water operating pressure with standard nozzle | 22 MPa |
Operating pressure (max.) | 25 MPa |
Water flow rate | 16,67 l/min |
High-pressure gun recoil force | 58 N |
Dimensions and weights | |
Typical operating weight | 67 kg |
Length | 607 mm |
Width | 518 mm |
Height | 1063 mm |
Oil volume | 1 l |
Oil type | SAE 90 Type |
Determined values in acc. with EN 60335-2-79 | |
Hand-arm vibration value | 6,6 m/s2 |
Uncertainty K | 1,2 m/s2 |
Sound pressure level LpA | 75 dB(A) |
Uncertainty KpA | 3 dB(A) |
Measured sound power level LWA | 91 dB(A) |
Guaranteed sound power level LWA,d | 93 dB(A) |
Country variant | |
Country | EU II |
Electrical connection | |
Voltage | 230 V |
Phase | 3 ~ |
Frequency | 50 Hz |
Maximum permissible mains grid impedance | 0.0452 + j0.0283 Ω |
Power rating | 8,5 kW |
Degree of protection | IPX5 |
Power protection (slow-blow, char. C) | 25 A |
Extension cable, 10 m | 2,5 mm2 |
Extension cable, 30 m | 4 mm2 |
Water connection | |
Feed pressure (max.) | 1 MPa |
Input temperature (max.) | 60 °C |
Input amount (min.) | 1200 l/h |
Suction height (max.) | 0,5 m |
Minimum water supply hose length | 7,5 m |
Minimum water supply hose diameter | 1 in |
Suction filter order number | 4.730-012.0 |
Device performance data | |
Nozzle size of standard nozzle | 050 |
Water operating pressure with standard nozzle | 23 MPa |
Operating pressure (max.) | 26 MPa |
Water flow rate | 16,67 l/min |
High-pressure gun recoil force | 60 N |
Dimensions and weights | |
Typical operating weight | 75 kg |
Length | 607 mm |
Width | 518 mm |
Height | 1063 mm |
Oil volume | 1 l |
Oil type | SAE 90 Type |
Determined values in acc. with EN 60335-2-79 | |
Hand-arm vibration value | 5,3 m/s2 |
Uncertainty K | 1,3 m/s2 |
Sound pressure level LpA | 75 dB(A) |
Uncertainty KpA | 3 dB(A) |
Measured sound power level LWA | 91 dB(A) |
Guaranteed sound power level LWA,d | 93 dB(A) |
Country variant | |
Country | EU |
Electrical connection | |
Voltage | 400 V |
Phase | 3 ~ |
Frequency | 50 Hz |
Maximum permissible mains grid impedance | 0.0452+j0.0283 Ω |
Power rating | 8,8 kW |
Degree of protection | IPX5 |
Power protection (slow-blow, char. C) | 16 A |
Extension cable, 10 m | 2,5 mm2 |
Extension cable, 30 m | 4 mm2 |
Water connection | |
Feed pressure (max.) | 1 MPa |
Input temperature (max.) | 60 °C |
Input amount (min.) | 1500 l/h |
Suction height (max.) | 0,5 m |
Minimum water supply hose length | 7,5 m |
Minimum water supply hose diameter | 1 in |
Suction filter order number | 4.730-012.0 |
Device performance data | |
Nozzle size of standard nozzle | 075 |
Water operating pressure with standard nozzle | 18 MPa |
Operating pressure (max.) | 25 MPa |
Water flow rate | 21,67 l/min |
High-pressure gun recoil force | 68 N |
Dimensions and weights | |
Typical operating weight | 69,8 kg |
Length | 607 mm |
Width | 518 mm |
Height | 1063 mm |
Oil volume | 1,0 l |
Oil type | SAE 90 Type |
Determined values in acc. with EN 60335-2-79 | |
Hand-arm vibration value | 3,7 m/s2 |
Uncertainty K | 0,9 m/s2 |
Sound pressure level LpA | 74 dB(A) |
Uncertainty KpA | 3 dB(A) |
Measured sound power level LWA | 91 dB(A) |
Guaranteed sound power level LWA,d | 93 dB(A) |
Country variant | |
Country | EU |
Electrical connection | |
Voltage | 400 V |
Phase | 3 ~ |
Frequency | 50 Hz |
Maximum permissible mains grid impedance | 0.0452+j0.0283 Ω |
Power rating | 8,8 kW |
Degree of protection | IPX5 |
Power protection (slow-blow, char. C) | 16 A |
Extension cable, 10 m | 2,5 mm2 |
Extension cable, 30 m | 4 mm2 |
Water connection | |
Feed pressure (max.) | 1 MPa |
Input temperature (max.) | 60 °C |
Input amount (min.) | 1500 l/h |
Suction height (max.) | 0,5 m |
Minimum water supply hose length | 7,5 m |
Minimum water supply hose diameter | 1 in |
Suction filter order number | 4.730-012.0 |
Device performance data | |
Nozzle size of standard nozzle | 075 |
Water operating pressure with standard nozzle | 18 MPa |
Operating pressure (max.) | 25 MPa |
Water flow rate | 21,67 l/min |
High-pressure gun recoil force | 68 N |
Dimensions and weights | |
Typical operating weight | 81,4 kg |
Length | 607 mm |
Width | 518 mm |
Height | 1063 mm |
Oil volume | 1,0 l |
Oil type | SAE 90 Type |
Determined values in acc. with EN 60335-2-79 | |
Hand-arm vibration value | 3,7 m/s2 |
Uncertainty K | 0,9 m/s2 |
Sound pressure level LpA | 75 dB(A) |
Uncertainty KpA | 3 dB(A) |
Measured sound power level LWA | 91 dB(A) |
Guaranteed sound power level LWA,d | 93 dB(A) |
EU Declaration of Conformity |
We hereby declare that the machine described below complies with the relevant basic safety and health requirements in the EU Directives, both in its basic design and construction as well as in the version placed in circulation by us. This declaration is invalidated by any changes made to the machine that are not approved by us.
Product: High-pressure cleaner
Type: 1.286-xxx.x
Currently applicable EU Directives2000/14/EC
2006/42/EC (+2009/127/EC)
2011/65/EU
2014/30/EU
2009/125/EC
Commission Regulation(s)(EU) 2019/1781
Applied harmonized standardsEN 60335-1
EN 60335-2-79
EN IEC 63000: 2018
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 1997+A1: 2001+A2: 2008
EN 61000-3-2: 2014
EN 61000-3-3: 2013
HD 9/20-4 SHD 10/21-4 SEN 61000-3-11: 2020
HD 13/18-4 SHD 10/25-4 SEN 62233: 2008
National standards used-
Sound power level dB(A)HD 9/20-4 S(XA)
Measured: 91
Guaranteed: 93
HD 10/21-4 S(XA)
Measured: 91
Guaranteed: 93
HD 13/18-4 S(XA)
Measured: 91
Guaranteed: 93
HD 10/25-4 S(XA)
Measured: 91
Guaranteed: 93
Measured:
Guaranteed:
Measured:
Guaranteed:
Measured:
Guaranteed:
Measured:
Guaranteed:
The signatories act on behalf of and with the authority of the company management.
Documentation supervisor:
S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2023/08/01
Declaration of Conformity (UK) |
We hereby declare that the product described below complies with the relevant provisions of the following UK Regulations, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the product is modified without our prior approval.
Product: High-pressure cleaner
Type: 1.286-xxx.x
Currently applicable UK RegulationsS.I. 2001/1701 (as amended)
S.I. 2008/1597 (as amended)
S.I. 2012/3032 (as amended)
S.I. 2016/1091 (as amended)
S.I. 2010/2617 (as amended)
Commission Regulation(s)(EU) 2019/1781
Applied designated standardsEN 60335-1
EN 60335-2-79
EN IEC 63000: 2018
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 1997+A1: 2001+A2: 2008
EN 61000-3-2: 2014
EN 61000-3-3: 2013
HD 9/20-4 SHD 10/21-4 SEN 61000-3-11: 2020
HD 13/18-4 SHD 10/25-4 SEN 62233: 2008
National standards used-
Sound power level dB(A)HD 9/20-4 S(XA)
Measured: 91
Guaranteed: 93
HD 10/21-4 S(XA)
Measured: 91
Guaranteed: 93
HD 13/18-4 S(XA)
Measured: 91
Guaranteed: 93
HD 10/25-4 S(XA)
Measured: 91
Guaranteed: 93
Measured:
Guaranteed:
Measured:
Guaranteed:
Measured:
Guaranteed:
Measured:
Guaranteed:
The signatories act on behalf of and with the authority of the company management.
Documentation supervisor:
S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2023/08/01
6-2-NN-A5-GS-20906