BVL 5/1 BpBVL 5/1 Bp Pack
59692990 (05/21)
59692990 (05/21)
Read these original instructions and the enclosed safety instructions before using the device for the first time. Act in accordance with them.
Keep both books for future reference or for future owners.
If the operating instructions and safety instructions are not observed, the device can be damaged and dangers could arise for users and other persons.
Notify the dealer immediately in the case of shipping damage.
Check the package contents when unpacking for missing accessories or for damage.
The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.
Electrical and electronic appliances contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which - if handled or disposed of incorrectly - can pose a potential threat to human health and the environment. However, these components are required for the correct operation of the appliance. Appliances marked by this symbol are not allowed to be disposed of together with the household rubbish.
Notes on the content materials (REACH)Current information on content materials can be found at: www.kaercher.com/REACH
Health risk
Inhalation of dusts that are harmful to health
Do not use the device for vacuuming up dusts that are harmful to health.
Damage to the device
Short-circuit due to high levels of humidity
Only use and store the device indoors.
This universal vacuum cleaner for carpets is intended for dry cleaning floor and wall surfaces.
This device is suitable for commercial use, e.g. in hotels, schools, hospitals, factories, shops, offices, and rental companies.
Danger due to radiated high frequency/electric magnetic fields
Health risk when wearing a pacemaker
Observe the following safety instructions when handling the device.
If you are wearing a pacemaker, we recommend that you consult your doctor or the manufacturer of the pacemaker about possible precautions before operating the device.
Not all types of pacemakers are equally resistant to radiation in the immediate vicinity of radiated high frequency/electric magnetic fields, which could lead to problems in the operation of the device.
If your doctor can not guarantee your safety, do not use the device!
Control elements for the cleaning process are yellow.
Control elements for maintenance and servicing are light grey.
Suction hose connection for right-handed users | |
Suction hose connection for left-handed users | |
QR code for video instructions |
Unpack the device and install the accessories.
Check if the main filter basket is inserted in the device.
Operation with the filter bag
Operation without the filter bag
Slide the battery pack into the battery holder and lock it in place.
Put the device on its back.
Engage the buckle of the hip belt and adjust the hip belt.
Engage the buckle of the chest strap and adjust the chest strap (height adjustable). Adjust the device to the body by pulling on the centre straps. Do not put on too tight, the main load should be on the hip belt.
Please read the operating instructions of the charger manufacturer, especially the chapters on safety instructions!
Please read the operating instructions of the battery pack manufacturer, especially the chapters on safety instructions!
The battery pack is partially charged on delivery. Charge before use and when necessary.
The battery pack can only be charged when it is removed.
Press the unlocking button and remove the battery pack.
Charge the battery pack according to the operating instructions of the charger manufacturer and the battery pack manufacturer.
Danger due to technical defect
Risk of damage to the device
Immediately switch off the engine as the suction performance decreases.
Align the dirt receptacle so that the suction hose comes out on the working side when the carrying system is worn (right/left-handed operation). The respective symbol can then be seen on the front.
Switch on the device at the main switch.
Eco button (energy-saving mode): The device works with reduced suction performance. The battery run time is extended.
To activate Eco-mode: Actuate the Eco button.
To switch off Eco-mode: Actuate the Eco button repeatedly.
Regulate the suction power on the suction control.
Set the floor nozzle switch to hard surface or carpet.
Perform cleaning.
Change of location/work interruption: If necessary, hang the telescopic suction pipe on the hook of the shoulder strap so that you have both hands free. The hook can be attached to the right or left shoulder strap.
Switch off the device at the main switch.
Empty the dirt receptacle.
Clean the device and accessories with a damp cloth after use.
Push in the telescopic suction pipe. Store the telescopic suction pipe and floor nozzle as shown in the illustration.
Store the device in a dry room or hang it by the handle and secure it against unauthorised use.
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during transportation.
When transporting the device in vehicles, secure it to prevent it from slipping or overturning in accordance with the respective valid guidelines.
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during storage.
The device may only be stored indoors.
Press the unlocking button and remove the battery pack to prevent discharge.
Danger of electric shock
Injuries due to touching live parts
Switch off the device.
Remove the battery pack.
Unlock and remove the dirt receptacle.
Figure 1
Remove the main filter basket.
Remove the fleece filter bag.
Pull the new fleece filter bag with rubber flange over the suction hose port (inside).
Put the main filter basket back on.
Figure 2
Fit and lock the dirt receptacle.
Figure 3
Danger from wet main filter basket
Risk of damage to the device
Never insert the main filter basket when wet.
If necessary, clean the main filter basket under running water.
HEPA filter (special accessory): Change once a year
Unlock and remove the dirt receptacle (including the main filter basket).
Turn the suction head by 180°.
Unlock and remove the HEPA filter (special accessory).
Insert a new HEPA filter (special accessory) and click it into place.
Turn the suction head by 180°.
Insert and lock the dirt receptacle (including the main filter basket).
Unlock and remove the dirt receptacle (including the main filter basket).
Turn the suction head by 180°.
If necessary, unlock and remove the HEPA filter (special accessory).
Remove the motor protection filter.
Fit the new motor protection filter.
If necessary, insert the HEPA filter (special accessory) and click it into place.
Turn the suction head by 180°.
Insert and lock the dirt receptacle (including the main filter basket).
Unlock and remove the dirt receptacle (including the main filter basket).
Readjust the closure strap so that the dirt receptacle (including the main filter basket) lies tightly against the suction head.
Insert and lock the dirt receptacle (including the main filter basket).
Danger of electric shock
Injuries due to touching live parts
Switch off the device.
Remove the battery pack.
The device must be switched off immediately if a malfunction occurs (e.g. filter breakage). The malfunction must be eliminated before switching the device on again.
The device stops during operation
Cause:
The motor thermo-protector has triggered
Remedy:
Changing the fleece filter bag.
Replace the motor protection filter.
Check all parts for clogging.
Switch on the device.
Suction power decreases
Remedy:
Changing the fleece filter bag.
Clean the main filter basket under running water and dry.
Correctly position/lock the dirt receptacle (including the main filter basket), readjust the closure strap if necessary.
Escaping dust when vacuuming
Remedy:
Change the faulty fleece filter bag.
Check the fit of the fleece filter bag.
Correctly position/lock the dirt receptacle (including the main filter basket), readjust the closure strap if necessary.
Insert the undamaged main filter basket.
Insert the motor protection filter correctly.
No or insufficient suction performance
Remedy:
Remove any blockages from the suction nozzle, suction pipe or suction hose.
Replace the defective suction hose.
Changing the fleece filter bag.
Correctly position/lock the dirt receptacle (including the main filter basket), readjust the closure strap if necessary.
Clean the main filter basket under running water and dry.
Insert the undamaged main filter basket.
Replace the motor protection filter.
Device not running
Remedy:
Switch on the device.
Allow the overheated board to cool down.
Charge the battery pack.
Insert the battery pack.
If the malfunction cannot be corrected, the device must be checked by the Customer Service department.
The device stops during operation
Cause:
The motor thermo-protector has triggered
Remedy:
Changing the fleece filter bag.
Replace the motor protection filter.
Check all parts for clogging.
Switch on the device.
Suction power decreases
Remedy:
Changing the fleece filter bag.
Clean the main filter basket under running water and dry.
Correctly position/lock the dirt receptacle (including the main filter basket), readjust the closure strap if necessary.
Escaping dust when vacuuming
Remedy:
Change the faulty fleece filter bag.
Check the fit of the fleece filter bag.
Correctly position/lock the dirt receptacle (including the main filter basket), readjust the closure strap if necessary.
Insert the undamaged main filter basket.
Insert the motor protection filter correctly.
No or insufficient suction performance
Remedy:
Remove any blockages from the suction nozzle, suction pipe or suction hose.
Replace the defective suction hose.
Changing the fleece filter bag.
Correctly position/lock the dirt receptacle (including the main filter basket), readjust the closure strap if necessary.
Clean the main filter basket under running water and dry.
Insert the undamaged main filter basket.
Replace the motor protection filter.
Device not running
Remedy:
Switch on the device.
Allow the overheated board to cool down.
Charge the battery pack.
Insert the battery pack.
The warranty conditions issued by our relevant sales company apply in all countries. We shall remedy possible malfunctions on your appliance within the warranty period free of cost, provided that a material or manufacturing defect is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.
(See overleaf for the address)
Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.
Information on accessories and spare parts can be found at www.kaercher.com.
Only use KÄRCHER original battery packs, not non-rechargeable batteries.
Description | Order number, spare part | Item No., unpacked |
---|---|---|
Battery pack Battery Power+ 36/75 | 2.445-043.0 | 6.445-059.0 |
Battery pack Battery Power+ 36/60 | 2.042-022.0 | 6.445-085.0 |
Battery pack Battery Power 36/50 | 2.445-031.0 | 6.445-039.0 |
Quick charger Battery Power+ 36/60 (EU) | 2.445-045.0 | 6.445-063.0 |
Quick charger Battery Power+ 36/60 (GB) | 2.445-047.0 | 6.445-065.0 |
Quick charger Battery Power+ 36/60 (AU) | 2.445-051.0 | 6.445-069.0 |
EU Declaration of Conformity |
We hereby declare that the machine described below complies with the relevant basic safety and health requirements in the EU Directives, both in its basic design and construction as well as in the version placed in circulation by us. This declaration is invalidated by any changes made to the machine that are not approved by us.
Product: Dry vacuum cleaner
Type: 1.394-xxx
Currently applicable EU Directives2006/42/EC (+2009/127/EC)
2011/65/EU
2014/30/EU
Harmonised standards usedEN IEC 63000: 2018
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 2015
EN 60312-1: 2017
EN 60335-1
EN 60335-2-69
EN 62233: 2008
National standards used-
The signatories act on behalf of and with the authority of the company management.
Documentation supervisor:
S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2020/10/01
Declaration of Conformity (UK) |
We hereby declare that the product described below complies with the relevant provisions of the following UK Regulations, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the product is modified without our prior approval.
Product: Dry vacuum cleaner
Type: 1.394-xxx
Currently applicable UK RegulationsS.I. 2008/1597 (as amended)
S.I. 2012/3032 (as amended)
S.I. 2016/1091 (as amended)
Designated standards usedEN IEC 63000: 2018
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 2015
EN 60312-1: 2017
EN 60335-1
EN 60335-2-69
EN 62233: 2008
National standards used-
The signatories act on behalf of and with the authority of the company management.
Documentation supervisor:
S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2020/10/01
Electrical connection | |
Battery pack nominal voltage | 36 DC V |
Protection class | III |
Nominal power | 500 W |
Maximum power | 500 W |
Device performance data | |
Tank content | 5 l |
Air quantity (max.) | 40 l/s |
Vacuum (max.) | 22,3 (223) kPa (mbar) |
Operating time at full battery charge - Battery Power 36/50 battery pack | 19/Eco: 43 Minutes |
Operating time at full battery charge - Battery Power+ 36/60 battery pack | 22/Eco: 50 Minutes |
Operating time at full battery charge - Battery Power+ 36/75 battery pack | 30/Eco: 64 Minutes |
Dimensions and weights | |
Typical operating weight | 5,0 kg |
Length x width x height | 220 x 320 x 510 mm |
Diameter of the suction hose | 35 mm |
Length of the suction hose | 1,0 m |
Ambient conditions | |
Ambient temperature | 0/+40 °C |
Determined values in acc. with EN 60335-2-69 | |
Sound pressure level LpA | 65 dB(A) |
Uncertainty KpA | 2 dB(A) |
Hand-arm vibration value | <2,5 m/s2 |
Uncertainty K | 0,2 m/s2 |