LogoAir Purifier AF 20
  • general notes
  • Safety instructions
    • Hazard levels
    • General safety instructions
  • Intended use
  • Environmental protection
  • Accessories and spare parts
  • Scope of delivery
  • Warranty
  • Description of the device
  • Inserting the filter
  • Operation
    • Switching the device on/off
    • Setting auto mode
    • Setting sleep mode
    • Setting the fan level
    • Setting the timer
    • Lock / unlock control panel
    • Display PM 2.5 air quality
  • Transport and storage
  • Care and service
  • Troubleshooting guide
    • The device cannot be switched on

    • Airflow is reduced

    • Odour elimination ineffective

    • Poor air quality

  • EU Declaration of Conformity
  • Technical data

      Air Purifier AF 20

      59699440 (06/22)

      general notes

      Read these original instructions and the safety instructions chapter before using the device for the first time. Act in accordance with them.

      Keep these original instructions for future reference or for future owners.

      Safety instructions

      Hazard levels

      DANGER

      Indication of an imminent threat of danger that will lead to severe injuries or even death.

      WARNING

      Indication of a potentially dangerous situation that may lead to severe injuries or even death.

      CAUTION

      Indication of a potentially dangerous situation that may lead to minor injuries.

      ATTENTION

      Indication of a potentially dangerous situation that may lead to damage to property.

      General safety instructions

      DANGER

      Only connect the device to alternating current. The voltage indicated on the type plate must match the voltage of the power source.

      DANGER

      Never touch the mains plug and socket with wet hands.

      DANGER

      Risk of asphyxiation. Keep packaging film out of the reach of children.

      DANGER

      Operation in explosive atmospheres is prohibited.

      WARNING

      Persons with reduced physical, sensory or mental capabilities, or those with a lack of experience and knowledge, are only allowed to use the appliance if they are supervised or have been instructed with respect to using the appliance safely, and understand the resultant dangers involved.

      WARNING

      Children from the age of 8 may use the appliance if they are supervised or have been instructed in its use by a person responsible for their safety, and if they have understood the resultant dangers involved.

      WARNING

      Children must not play with the appliance.

      WARNING

      Children must be supervised to prevent them from playing with the appliance.

      WARNING

      Children may only perform cleaning work and user maintenance under supervision.

      WARNING

      Check the power supply cable with mains plug for damage before operation each time. Do not put the device into operation with a damaged power supply cable. Have a damaged power supply cable replaced immediately by the authorised customer service / qualified electrician.

      WARNING

      Switch off the device immediately and remove the mains plug before performing any care and service work.

      CAUTION

      Do not pull the mains plug out the socket using the power supply cable.

      CAUTION

      Have repair work, installation of spare parts and work on electrical components carried out by the authorised customer service only.

      CAUTION

      It is prohibited to cover the air inlet and outlet.

      CAUTION

      Switch off the device after each use and remove the mains plug.

      CAUTION

      Do not place the device near a heat source.

      CAUTION

      The device is not a replacement for appropriate ventilation.

      CAUTION

      The device must be placed on an even, firm subsurface.

      CAUTION

      Only use accessories and spare parts which are approved by the manufacturer. Only original accessories and original spare parts ensure that the appliance will run fault-free and safely.

      CAUTION

      Do not use the device in damp conditions or in rooms with high ambient temperatures, e.g. bathroom.

      Intended use

      In accordance with the descriptions and safety instructions listed in these operating instructions, use the device only as an air purifier.

      • The device is intended for use as an air purifier.

      • The device is suitable for both private and commercial use.

      • The device is intended only for indoor use.

      Environmental protection

      The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.

      Electrical and electronic appliances contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which - if handled or disposed of incorrectly - can pose a potential threat to human health and the environment. However, these components are required for the correct operation of the appliance. Appliances marked by this symbol are not allowed to be disposed of together with the household rubbish.

      Notes on the content materials (REACH)

      Current information on content materials can be found at: www.kaercher.com/REACH

      Accessories and spare parts

      Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.

      Information on accessories and spare parts can be found at www.kaercher.com.

      Scope of delivery

      The scope of delivery for the appliance is shown on the packaging. Check the contents for completeness when unpacking. If any accessories are missing or in the event of any shipping damage, please notify your dealer.

      Warranty

      The warranty conditions issued by our relevant sales company apply in all countries. We shall remedy possible malfunctions on your appliance within the warranty period free of cost, provided that a material or manufacturing defect is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.

      (See overleaf for the address)

      Description of the device

      For the illustrations, refer to the graphics page.


      1. Operation button for Device On / Off
      2. Operation button for Function lock
      3. Display PM 2.5 Air quality index
      4. Operation button for Switch off display
      5. Display for fan level
      6. Operation button for Auto mode On / Off
      7. Fan level operation button
      8. Operation button for Sleep mode On / Off
      9. Timer display
      10. Operation button for Timer
      11. Filter service life display
      12. Operation button for Filter reset
      13. Air quality display and device display
      14. Filter cover lock
      15. Filter cover
      16. Filter tab
      17. filter
      18. Connection for power supply unit
      19. Device sensor
      20. AC power adapter

      Note

      The function settings are only possible via the operation buttons and not via the displays.

      Inserting the filter

      Before initial start up, the fine filters already installed in the unit must be unpacked.

      1. Turn the device over, and turn the filter cover lock 45 degrees clockwise.


      2. Remove the filter cover.


      3. Remove the packed filters.


      4. Unpack the filters.


      5. Insert the unpacked filters. Ensure that the draw shackles are visible and point inwards.


      6. Put on the filter cover and turn the lock 45 degrees anticlockwise. Turn the device over with the display facing upwards.


      7. Place the device on a level surface. Ensure that a distance of 30 cm is maintained to each side.


        Note

        Do not place the device on hot surfaces or in the immediate vicinity of the room heating.

        Do not allow any liquids or foreign bodies (e.g. metallic objects) to enter the device.

      8. Insert the plug of the power supply unit into the device and insert the mains plug into the socket.


      The device is ready for operation.

      Note

      The first time you use the device, we recommend allowing it to run overnight to perform an initial basic cleaning of your room.

      Note

      The table with the hours of the display symbols for the filter service life, see (→)

      Operation

      Switching the device on/off

      1. To switch on the device: Press the on/off button on the device.


        The device starts automatically.

        Note

        After the system is switched on, the displays and buttons on the control panel light up briefly. The integrated air quality sensor measures the air quality in the room automatically.

      2. If required, the following functions, for example, can be set via the operation buttons:

        • Fan level

        • Auto mode

        • Sleep mode

        • Timer

      3. To switch off the device: Press the On/Off switch of the device.

        The displays and buttons on the control panel go out. The device is switched off.

      Setting auto mode

      In automatic mode, the air purifier sets the appropriate fan level depending on the air quality.

      In the event of poor air quality, for example, the fan level is automatically set high.

      Symbol for the auto mode operation button:

      • Press the auto mode operation button. The automatic mode is switched on or off.

      Setting sleep mode

      In sleep mode, the fan runs at the lowest speed and is therefore very quiet. All light symbols are off.

      • Press the sleep mode operation button. The sleep mode is switched on or off.

      Symbol for the sleep mode operation button:

      Setting the fan level

      Depending on the air quality, the fan level can be manually set to level I, II or III. If the air quality is poor, for example to filter out smoke, the blower should run at maximum speed (level III) for 15 - 20 minutes.

      Note

      To clean the air effectively, keep windows and doors closed while the air purifier is switched on.

      Symbol for the fan level operation button:

      • Press the fan level operation button repeatedly until the desired level is reached.

        The selected fan level is displayed on the control panel.

      Setting the timer

      The timer can be set to 2, 4, 6 or 8 h run time. When the set time has elapsed, the device switches off automatically. The fan level can be changed at any time.

      Symbol for the timer operation button:

      • Switching on: Press the Timer operation button repeatedly until the desired run time is reached. The display lights up. The set run time is displayed in the control panel.

      • Switching off: Press the Timer operation button until the timer display goes out. Timer is off.

      Lock / unlock control panel

      To prevent accidental change of settings, e.g. by children or pets, the control panel can be locked.

      Symbol for the lock operation button and display for control panel:

      • Lock: Press the button for 3 seconds.

      • Unlock: Press the lock button for 3 seconds.

      Display PM 2.5 air quality

      The display shows the concentration of fine dust (PM 2.5) numerically in the unit µg/m³. In addition, a colour index provides information about the air quality:

      PM 2.5
      Air quality
      Colour
      0 - 60
      Good
      Blue
      61 - 120
      Moderate
      Yellow
      >120
      Poor
      Red

      Transport and storage

      CAUTION

      Failure to observe the weight

      Risk of injury and damage

      Be aware of the weight of the device during transport and storage.

      Store the device only in dry indoor rooms.

      Care and service

      Troubleshooting guide

      Malfunctions often have simple causes that you can remedy yourself using the following overview. When in doubt, or in the case of malfunctions not mentioned here, please contact your authorised Customer Service.

      • The device cannot be switched on 

      • Airflow is reduced 

      • Odour elimination ineffective 

      • Poor air quality 

      The device cannot be switched on

      Cause:

      No electrical voltage present

      Remedy:

      • Check the socket and the power supply fuse.

      • Insert the plug of the power supply unit into another socket.

      Cause:

      Power supply unit defective

      Remedy:

      • Contact Customer Service to replace the power supply unit.

      Cause:

      Device defective

      Remedy:

      • Contact Customer Service.

      Airflow is reduced

      Cause:

      Filter clogged

      Remedy:

      • Changing the filter, see chapter (→).

      Cause:

      Filter not unpacked

      Remedy:

      • Unpacking the filter, see chapter Inserting the filter.

      Cause:

      Fan level too low

      Remedy:

      • Increasing the fan level, see chapter Setting the fan level.

      Cause:

      Air outlet is blocked

      Remedy:

      • Remove foreign bodies.

      Odour elimination ineffective

      Cause:

      Poor ambient air quality

      Remedy:

      • Open windows to improve ventilation.

      Cause:

      Filter used up or used too long

      Remedy:

      • Replace the filter.

      Cause:

      Fan level too low

      Remedy:

      • Increasing the fan level, see chapter Setting the fan level.

      Poor air quality

      Cause:

      Fan level too low

      Remedy:

      • Increasing the fan level, see chapter Setting the fan level.

      Cause:

      Draught

      Remedy:

      • Close the windows and doors while the device is working.

      Cause:

      AF 20: Room size clearly above 20 m²

      Remedy:

      • Observe the maximum room size.

      Cause:

      AF 30: Room size clearly above 30 m²

      Remedy:

      • Observe the maximum room size.

      Cause:

      AF 50: Room size clearly above 50 m²

      Remedy:

      • Observe the maximum room size.

      Cause:

      Air slots on the device blocked

      Remedy:

      • Keep the required distances from the device.

      • Do not place anything on the device.

      Cause:

      Filter not unpacked

      Remedy:

      • Unpacking the filter, see chapter Inserting the filter.

      Cause:

      Filter clogged or contaminated.

      Remedy:

      • Changing the filter, see chapter (→).

      EU Declaration of Conformity

      We hereby declare that the machine described below complies with the relevant basic safety and health requirements in the EU Directives, both in its basic design and construction as well as in the version placed in circulation by us. This declaration is invalidated by any changes made to the machine that are not approved by us.

      Product: Air purifier

      Type: 1.351-xxx

      Currently applicable EU Directives

      2014/35/EU

      2014/30/EU

      2011/65/EU

      Harmonised standards used

      EN 60335-1

      EN 60335-2-65

      EN 55014-1: 2017 + A11: 2020

      EN 55014-2: 2015

      EN 61000-3-2: 2014

      EN 61000-3-3: 2013

      EN 62233: 2008

      EN IEC 63000: 2018

      National standards used

      -

      The signatories act on behalf of and with the authority of the company management.


      Documentation supervisor:

      S. Reiser

      Alfred Kärcher SE & Co. KG

      Alfred-Kärcher-Str. 28 - 40

      71364 Winnenden (Germany)

      Ph.: +49 7195 14-0

      Fax: +49 7195 14-2212

      Winnenden, /04/01

      Technical data

        

      Electrical connection
      Mains voltage
      DC24V V
      Phase
      1 ~
      Power frequency
      50 - 60 Hz
      Nominal power
      24 W
      Standby
      <0,5 W
      Device performance data
      Clean air flow rate
      220 m3/h
      Floor space
      * 20 m2
      Filter efficiency at 0.3 μm
      99,95%
      Maximum filter working time (depending on environment)
      3000 h
      3 Ventilation levels
      Dimensions and weights
      Weight
      2.7 kg
      Length x width x height
      220x220x343 mm
      Ambient conditions
      Ambient temperature
      - 10 °C - + 40 °C °C
      Determined values in acc. with EN 60335-2-69
      Sound pressure level
      27-52 dB(A)
      <BackPage>

       