Air Purifier AF 20
59699440 (03/23)
59699440 (03/23)
Read these original instructions and the safety instructions chapter before using the device for the first time. Act in accordance with them.
Keep these original instructions for future reference or for future owners.
Indication of an imminent threat of danger that will lead to severe injuries or even death.
Indication of a potentially dangerous situation that may lead to severe injuries or even death.
Indication of a potentially dangerous situation that may lead to minor injuries.
Indication of a potentially dangerous situation that may lead to damage to property.
Only connect the device to alternating current. The voltage indicated on the type plate must match the voltage of the power source.
Never touch the mains plug and socket with wet hands.
Risk of asphyxiation. Keep packaging film out of the reach of children.
Operation in explosive atmospheres is prohibited.
Persons with reduced physical, sensory or mental capabilities, or those with a lack of experience and knowledge, are only allowed to use the appliance if they are supervised or have been instructed with respect to using the appliance safely, and understand the resultant dangers involved.
Children from the age of 8 may use the appliance if they are supervised or have been instructed in its use by a person responsible for their safety, and if they have understood the resultant dangers involved.
Children must not play with the appliance.
Children must be supervised to prevent them from playing with the appliance.
Children may only perform cleaning work and user maintenance under supervision.
Check the power supply cable with mains plug for damage before operation each time. Do not put the device into operation with a damaged power supply cable. Have a damaged power supply cable replaced immediately by the authorised customer service / qualified electrician.
Switch off the device immediately and remove the mains plug before performing any care and service work.
Do not pull the mains plug out the socket using the power supply cable.
Have repair work, installation of spare parts and work on electrical components carried out by the authorised customer service only.
It is prohibited to cover the air inlet and outlet.
Switch off the device after each use and remove the mains plug.
Do not place the device near a heat source.
The device is not a replacement for appropriate ventilation.
The device must be placed on an even, firm subsurface.
Only use accessories and spare parts which are approved by the manufacturer. Only original accessories and original spare parts ensure that the appliance will run fault-free and safely.
Do not use the device in damp conditions or in rooms with high ambient temperatures, e.g. bathroom.
In accordance with the descriptions and safety instructions listed in these operating instructions, use the device only as an air purifier.
The device is intended for use as an air purifier.
The device is suitable for both private and commercial use.
The device is intended only for indoor use.
The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.
Electrical and electronic devices contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which - if handled or disposed of incorrectly - can pose a potential danger to human health and the environment. However, these components are required for the correct operation of the device. Devices marked by this symbol are not allowed to be disposed of together with the household rubbish.
Notes on the content materials (REACH)Current information on content materials can be found at: www.kaercher.de/REACH
Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.
Information on accessories and spare parts can be found at www.kaercher.com.
The scope of delivery for the appliance is shown on the packaging. Check the contents for completeness when unpacking. If any accessories are missing or in the event of any shipping damage, please notify your dealer.
The warranty conditions issued by our sales company responsible apply in all countries. We shall remedy possible malfunctions on your device within the warranty period free of cost, provided that a material or manufacturing defect is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.
You can find more detailed information at: www.kaercher.com/dealersearch
For the illustrations, refer to the graphics page.
The function settings are only possible via the operation buttons and not via the displays.
Before initial start up, the fine filters already installed in the unit must be unpacked.
Turn the device over, and turn the filter cover lock 45 degrees clockwise.
Remove the filter cover.
Remove the packed filters.
Unpack the filters.
Insert the unpacked filters. Ensure that the draw shackles are visible and point inwards.
Put on the filter cover and turn the lock 45 degrees anticlockwise. Turn the device over with the display facing upwards.
Place the device on a level surface. Ensure that a distance of 30 cm is maintained to each side.
Do not place the device on hot surfaces or in the immediate vicinity of the room heating.
Do not allow any liquids or foreign bodies (e.g. metallic objects) to enter the device.
Insert the plug of the power supply unit into the device and insert the mains plug into the socket.
The device is ready for operation.
The first time you use the device, we recommend allowing it to run overnight to perform an initial basic cleaning of your room.
The table with the hours of the display symbols for the filter service life, see Replacing the filter
To switch on the device: Press the on/off button on the device.
The device starts automatically.
After the system is switched on, the displays and buttons on the control panel light up briefly. The integrated air quality sensor measures the air quality in the room automatically.
If required, the following functions, for example, can be set via the operation buttons:
Fan level
Auto mode
Sleep mode
Timer
To switch off the device: Press the On/Off switch of the device.
The displays and buttons on the control panel go out. The device is switched off.
In automatic mode, the air purifier sets the appropriate fan level depending on the air quality.
In the event of poor air quality, for example, the fan level is automatically set high.
Symbol for the auto mode operation button:
Press the auto mode operation button. The automatic mode is switched on or off.
In sleep mode, the fan runs at the lowest speed and is therefore very quiet. All light symbols are off.
Press the sleep mode operation button. The sleep mode is switched on or off.
Symbol for the sleep mode operation button:
Depending on the air quality, the fan level can be manually set to level I, II or III. If the air quality is poor, for example to filter out smoke, the blower should run at maximum speed (level III) for 15 - 20 minutes.
To clean the air effectively, keep windows and doors closed while the air purifier is switched on.
Symbol for the fan level operation button:
Press the fan level operation button repeatedly until the desired level is reached.
The selected fan level is displayed on the control panel.
The timer can be set to 2, 4, 6 or 8 h run time. When the set time has elapsed, the device switches off automatically. The fan level can be changed at any time.
Symbol for the timer operation button:
Switching on: Press the Timer operation button repeatedly until the desired run time is reached. The display lights up. The set run time is displayed in the control panel.
Switching off: Press the Timer operation button until the timer display goes out. Timer is off.
To prevent accidental change of settings, e.g. by children or pets, the control panel can be locked.
Symbol for the lock operation button and display for control panel:
Lock: Press the button for 3 seconds.
Unlock: Press the lock button for 3 seconds.
The display shows the concentration of fine dust (PM 2.5) numerically in the unit µg/m³. In addition, a colour index provides information about the air quality:
PM 2.5 | Air quality | Colour |
---|---|---|
0 - 60 | Good | Blue |
61 - 120 | Moderate | Yellow |
>120 | Poor | Red |
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during transport and storage.
Store the device only in dry indoor rooms.
Danger of death from electric shock
Liquids can conduct electricity and thus cause serious or fatal injuries.
Always disconnect the power supply unit from the socket before cleaning and maintenance work.
Never immerse the device or the power supply unit in water.
Never use wet cloths to clean the device or the power supply unit.
Switch off the device.
Unplug the power supply unit from the socket.
Wipe the device with a soft, dry cloth. Do not use abrasive or corrosive detergents.
The filter should be changed after 2500 - 3000 hours of operation at the latest. If the device becomes louder, an unpleasant smell emanates from the device (filter) or the filter is visibly dirty, it should be changed at an earlier stage. The symbol flashes in the display to remind you of a required filter change.
Symbol for the operation button for filter reset:
Depending on the service life, the following number of symbols is displayed:
Display for service life of filter (h) | |
---|---|
2401 - 3000 | |
1801 - 2400 | |
1201 - 1800 | |
601 - 1200 | |
1 - 600 |
Switch off the device, and disconnect the power supply unit from the socket and device.
Turn the device over, and turn the filter cover lock 45 degrees clockwise.
Remove the filter cover.
Remove the filters.
Unpack the new filters.
Insert the unpacked filters. Ensure that the draw shackles are visible and point inwards.
Put on the filter cover and turn the lock 45 degrees anticlockwise. Turn the device over with the display facing upwards.
Connect the power supply unit to the device and socket.
Switch the device on.
To reset the filter (Reset), press the symbol for 3 seconds.
Malfunctions often have simple causes that you can remedy yourself using the following overview. When in doubt, or in the case of malfunctions not mentioned here, please contact your authorised Customer Service.
The device cannot be switched on
Cause:
No electrical voltage present
Remedy:
Check the socket and the power supply fuse.
Insert the plug of the power supply unit into another socket.
Cause:
Power supply unit defective
Remedy:
Contact Customer Service to replace the power supply unit.
Cause:
Device defective
Remedy:
Contact Customer Service.
Cause:
Filter cover not inserted correctly
Remedy:
Insert the filter cover correctly, making sure that the filters are seated correctly.
Airflow is reduced
Cause:
Filter clogged
Remedy:
Changing the filter, see chapter Replacing the filter.
Cause:
Filter not unpacked
Remedy:
Unpacking the filter, see chapter Inserting the filter.
Cause:
Fan level too low
Remedy:
Increasing the fan level, see chapter Setting the fan level.
Cause:
Air outlet is blocked
Remedy:
Remove foreign bodies.
Odour elimination ineffective
Cause:
Poor ambient air quality
Remedy:
Open windows to improve ventilation.
Cause:
Filter used up or used too long
Remedy:
Replace the filter.
Cause:
Fan level too low
Remedy:
Increasing the fan level, see chapter Setting the fan level.
Poor air quality
Cause:
Fan level too low
Remedy:
Increasing the fan level, see chapter Setting the fan level.
Cause:
Draught
Remedy:
Close the windows and doors while the device is working.
Cause:
AF 20: Room size clearly above 20 m²
Remedy:
Observe the maximum room size.
Cause:
AF 30: Room size clearly above 30 m²
Remedy:
Observe the maximum room size.
Cause:
AF 50: Room size clearly above 50 m²
Remedy:
Observe the maximum room size.
Cause:
Air slots on the device blocked
Remedy:
Keep the required distances from the device.
Do not place anything on the device.
Cause:
Filter not unpacked
Remedy:
Unpacking the filter, see chapter Inserting the filter.
Cause:
Filter clogged or contaminated.
Remedy:
Changing the filter, see chapter Replacing the filter.
We hereby declare that the machine described below complies with the relevant basic safety and health requirements in the EU Directives, both in its basic design and construction as well as in the version placed in circulation by us. This declaration is invalidated by any changes made to the machine that are not approved by us.
Product: Air purifier
Type: 1.351-xxx
Currently applicable EU Directives2014/35/EU
2014/30/EU
2011/65/EU
Harmonised standards usedEN 60335-1
EN 60335-2-65
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 2015
EN 61000-3-2: 2014
EN 61000-3-3: 2013
EN 62233: 2008
EN IEC 63000: 2018
National standards used-
The signatories act on behalf of and with the authority of the company management.
Documentation supervisor:
S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, /04/01
Electrical connection | |
Mains voltage | DC24V V |
Phase | 1 ~ |
Power frequency | 50 - 60 Hz |
Nominal power | 24 W |
Standby | <0,5 W |
Device performance data | |
Clean air flow rate | 220 m3/h |
Floor space | * 20 m2 |
Filter efficiency at 0.3 μm | 99,95% |
Maximum filter working time (depending on environment) | 3000 h |
3 Ventilation levels | |
Dimensions and weights | |
Weight | 2.7 kg |
Length x width x height | 220x220x343 mm |
Ambient conditions | |
Ambient temperature | - 10 °C - + 40 °C °C |
Determined values in acc. with EN 60335-2-69 | |
Sound pressure level | 26-52 dB(A) |