Read these original instructions and the safety instructions chapter before using the device for the first time. Act in accordance with them.
Keep these original instructions for future reference or for future owners.
You will find a QR Code® to call up the online operating instructions in the:
Trademarks
QR-Code® is a registered trademark of DENSO WAVE INCORPORATED.
Indication of an imminent threat of danger that will lead to severe injuries or even death.
Indication of a potentially dangerous situation that may lead to severe injuries or even death.
Indication of a potentially dangerous situation that may lead to minor injuries.
Indication of a potentially dangerous situation that may lead to damage to property.
Risk of asphyxiation. Keep packaging film out of the reach of children.
Only use the device for its intended purpose and take the local conditions into account.
Only supply the device with drinking water from a public water supplier. The quality of the drinking water must at least correspond to the guidelines of the World Health Organization (WHO).
This device must not be installed or serviced by persons (including children) with restricted physical, sensory or mental abilities or those lacking in experience and knowledge.
Health risk from germs. Pay attention to hygiene and cleanliness when replacing the filter cartridges. Wear sterile disposable gloves when changing the filter cartridges.Clean the surfaces of the device regularly. If your drinking water supplier has warned of contamination, you must renew all filter cartridges after the all-clear has been given.
Children must not play with the appliance.
Children must be supervised to prevent them from playing with the appliance.
Health risk due to improperly repaired device. The device may only be repaired by trained specialist personnel.
Do not use the appliance if it has been dropped beforehand, is visibly damaged or if it is leaking.
Do not clean the plastic surfaces of the device or the lines and connections with alcohol-based, aggressive or abrasive detergents.
Only operate and store the device and its water-carrying components in frost-free indoor areas.
The device is used to dispense filtered drinking water.
Filtered water is food and must be used within 1 to 2 days.
The device retains residues from the line, heavy metals, chlorine, hormone and drug residues, microplastics, bacteria and viruses, as well as substances that impair taste and smell. All minerals remain.
The input water must be drinking water according to WHO standards. The device is therefore not suitable for use with water of unknown origin, sea water or well water. It does not retain salts and minerals.
The filter material is subjected to a special treatment with silver. A small amount of silver, which is harmless to health, can be released into the water. This corresponds to the WHO recommendations for drinking water.
In the event of a request to boil tap water from an official body, e.g. the water supplier, the filter system must be taken out of operation. Once the boil order has been lifted, the filter cartridges must be renewed.
The unit can be used in the following areas:
In the household and similar applications
In tea kitchens and break rooms
In staff kitchen areas of shops, offices and other work areas
In hotels, motels, bed and breakfasts and other accommodations
Any type of improper use is prohibited.
The operating personnel are liable for damage resulting from incorrect use.
The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.
Old devices contain valuable, recyclable materials that should be recycled. Therefore, please dispose of old devices using suitable collection systems.
Notes on the content materials (REACH)Current information on content materials can be found at: www.kaercher.de/REACH
Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.
Information on accessories and spare parts can be found at www.kaercher.com.
When unpacking the device, check the contents of the box for completeness and for damage using the operating instructions. Please contact your dealer if any accessories are missing or in the event of any shipping damage.
Pre-Pure filter 2.644-302.0 (left)
Hy-Protect filter 2.644-303.0 (centre)
Post-Protect filter 2.644-304.0 (right)
*Not included in the scope of delivery.
Only operate and store the device and its water-carrying components in frost-free indoor areas.
Risk of material damage due to improper installation
Damage to sink / worktop and domestic plumbing as well as damage caused by leaking water.
Only install the device and its components yourself if you are capable of doing so and have the necessary knowledge and tools.
If in doubt, have the device installed by a person with professional knowledge.
After installation, be sure to check the tightness of the entire system.
The water temperature and the water inlet pressure must correspond to the specified values, see chapter Technical data.
For higher line pressures, always connect an external pressure reducer upstream!
Depending on local regulations, an approved backflow preventer must be installed.
Place the device on a flat, horizontal surface with the base facing downwards.
The front cover and the stop valve must be freely accessible.
The distance to heat-radiating appliances such as under-sink boilers or uninsulated hot water pipes must be at least 100 mm.
Only connect the device with the lines provided.
Do not use lines that are used.
Do not bend the lines and do not subject them to tension, torsion or compression.
Do not place any objects on the lines.
Connection diagram
Observe the connection diagram during installation:
Check the water inlet pressure at the pressure reducer of the building's drinking water installation. Under no circumstances may it exceed the maximum value specified in the Chapter Technical data. We recommend setting the water inlet pressure to 0.4 MPa (4 bar).
If there is no pressure reducer in the drinking water installation of the building, a separate pressure reducer must be connected upstream of the device.
If the value of the water inlet pressure cannot be determined in the drinking water installation of the building, a separate pressure reducer must be connected upstream of the device.
Select the installation position so that the tap is accessible for installation from below and the opening of the outlet is above the sink.
Allow sufficient space for connecting the 1/4″ line.
The material thickness A of the sink / worktop must not exceed 24 mm. If the material thickness is higher, the worktop can be provided with a corresponding countersink from below. If in doubt, have the device installed by a person with professional knowledge.
The upper and lower support surfaces must be flat and parallel, with a diameter B of at least 50 mm.
Installation diagram
Drill a hole with a diameter C of 12 mm for the installation of the tap.
Use suitable drills or tools for the material of the sink / worktop.
Pre-drill if necessary.
Remove the protective film from the anchor plate.
Fit the anchor plate and the sealing washer on the tap.
Insert the tap into the hole from above and align it.
Fit the washer from the bottom of the tap and tighten the wing nut.
Risk of damage due to excessive water temperature
Water with a temperature above 38° C irreversibly damages the filter cartridges.
Only connect the stop valve to the cold water inlet angle valve, never to a hot water inlet angle valve.
The corner valve for the cold water inlet is usually on the right, an optional corner valve for the hot water inlet is usually on the left.
Install the stop valve between the cold water inlet angle valve and the flexible hose.
Close the angle valve.
Unscrew the flexible hose on the cold water inlet angle valve.
Screw the stop valve with the seal onto the cold water inlet angle valve.
Screw the flexible hose onto the shut-off valve.
Set up the device so that the lines can be kept as short as possible.
The front cover must be accessible.
The lines are connected using sleeves with quick couplings, except at the stop valve.
At the stop valve, the line is fixed to the connection with a nut.
Connecting the line (except at the stop valve)
To connect a line:
Remove the clamp on the quick coupling.
Insert the line into the quick coupling as far as it will go.
Fit the clamp on the quick coupling.
Pull on the line to check that it is seated correctly.
Connecting a sleeve to the device or the tap is done in the same way.
Pulling off the line (except at the stop valve)
To pull off a line:
Remove the clamp on the quick coupling.
Push back the quick coupling and hold it in place.
Pull the line out of the quick coupling.
Pulling off a sleeve on the device or on the tap is done in the same way.
Connecting the line (at the stop valve)
To connect the line:
Unscrew the nut and slide it onto the line.
Insert the line into the connection as far as it will go.
Tighten the nut on the connection.
Pull on the line to check that it is seated correctly.
Pulling off the line (at the stop valve)
To pull off the line:
Unscrew the nuts.
Pull the line out of the connection.
Shortening the line
If necessary, carefully cut the line at right angles to the longitudinal axis with a sharp cutter knife.
Do not cut the line at an angle.
Do not deform the line.
Do not use scissors, side cutters or similar tools, as they deform the cable and change the line cross-section.
Connect the 3/8″ line to the stop valve.
Remove the transport cover from the rear cover, it is no longer needed.
Lay the 3/8″ line to the "IN" connection on the device.
Shorten the 3/8″ line if necessary.
Connect the 3/8″ line to the "IN" connection with the 3/8″ angle sleeve.
Connect the sleeve to the bottom of the tap.
Connect the 1/4″ line to the sleeve.
Lay the 1/4″ line to the "OUT" connection on the device.
Shorten the 1/4″ line if necessary.
Connect the 1/4″ line to the "OUT" connection with the 1/4″ angle sleeve.
Remove the front cover.
Grasp the recessed grip and pull off the front cover on the device.
To attach, place the front cover on the base and fold it onto the device.
Open the cold water inlet:
Open the cold water inlet angle valve.
Open the stop valve.
Check the device and all connections for leaks.
If there is a leak, close the cold water inlet angle valve and eliminate the leak.
Open the tap and drain off approx. 10 l of water, see chapter Operation.
The system is flushed, any residues are flushed out and the filter cartridges are vented.
It is normal for dark-coloured water to come out at the start, this is due to the use of active carbon.
Only use the water when it comes out fully clear.
Check the device and all connections for leaks again.
Close the water tap.
The device is now ready for use.
Open the water tap.
Turn the outlet to the desired position.
Turn the water removal lever anti-clockwise.
Every day, before using the water for the first time, first drain off 1 l of water.
The system is flushed and the high quality of the extracted water is ensured.
If no water has been drawn for more than 3 days, first drain off 10 l of water.
Improper cleaning
Risk of damage.
Do not use any abrasive or aggressive detergents.
Wipe the housing of the device regularly with a soft, damp cloth.
Filter cartridge | Change at the latest every |
---|---|
Pre Pure filter 2.644-302.0 | 6 months |
Hy-Protect filter 2.644-303.0 | 12 months |
Post-Protect filter 2.644-304.0 | 12 months |
The replacement interval of the filter cartridges varies depending on the quality of the inlet water. |
Health risk due to the entry of germs or insufficient filtration effect
Entry of germs due to improper installation, handling or repair.
Insufficient filtration effect due to incorrect installation or cleaning of the filter cartridge inserts or non-compliance with the change intervals.
Pay attention to hygiene and cleanliness when installing the filter cartridge.
Wear sterile disposable gloves when replacing filter cartridges.
Only unpack new filter cartridges immediately before installation.
Make sure that the filter cartridges are arranged correctly in the device.
Do not try to clean the filter inlays of the filter cartridges, but replace the filter cartridges when the replacement interval is reached or the filtration effect is insufficient. The filter inlays cannot be cleaned or refurbished.
Only have the device repaired by a trained professional.
Reduce the pressure in the system.
Close the stop valve.
Open the water tap.
Remove the front cover.
Grasp the recessed grip and pull off the front cover on the device.
To attach, place the front cover on the base and fold it onto the device.
Put on sterile disposable gloves.
Remove the filter cartridge to be replaced.
Disengage the filter cartridge from the clip and swing it out by max. 45°.
Turn the filter cartridge approx. 90° anticlockwise and remove it from the intake.
Dispose of the filter cartridge in the household rubbish.
Unpack the new filter cartridge.
Note the replacement date on the label of the filter cartridge.
Install the new filter cartridge.
Push the filter cartridge into the intake and turn it approx. 90° clockwise until it stops.
Swing the filter cartridge down until it engages in the clip.
Ensure the correct arrangement of the three different filter cartridges in the device. The correct position is shown on the label of each filter cartridge.
Vent the system and check for leaks, see chapter Initial startup.
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during transportation.
When transporting the device in vehicles, secure it to prevent it from slipping or overturning in accordance with the respectively applicable guidelines.
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during storage.
Store the device in a frost-protected place.
Malfunctions often have simple causes that you can remedy yourself using the following overview. When in doubt, or in the case of malfunctions not mentioned here, please contact your authorised Customer Service.
Leakage.
Cause:
Device is incorrectly installed.
Remedy:
Check for the correct installation of the stop valve, lines (must be inserted into the sleeves as far as they will go), sleeves and tap, install correctly if required, see Chapter Installing and connecting the device.
Cause:
Filter cartridges inserted incorrectly.
Remedy:
Check that the filter cartridges are correctly seated in the holders; if necessary insert the filter cartridges correctly, see Chapter Replacing the filter cartridge.
Cause:
Lines or sleeves are damaged or deformed.
Remedy:
Check the lines and sleeves for damage and deformation, replace damaged or deformed parts.
The device does not dispense enough water.
Cause:
The filter cartridges are clogged.
Remedy:
Check compliance with the change intervals of the filter cartridges, replace the corresponding filter cartridges if necessary.
If the change interval has not yet been reached, first replace the left filter cartridge and vent the device, see Chapter Initial startup.
If the device continues to dispense too little water, replace the middle filter cartridge in the same way.
If the device continues to dispense too little water, replace the right filter cartridge in the same way.
Cause:
The water supply is reduced.
Remedy:
Check the position of the cold water inlet angle valve and the stop valve, open fully if necessary.
Check the condition of the lines, repair kinks and damage if necessary.
If the malfunction persists, contact the service department.
Cause:
The water inlet pressure is too low.
Remedy:
Adjust the water inlet pressure to 4 bar on the pressure reducer of the building's drinking water installation or on the separate pressure reducer.
If the malfunction persists, contact the service department.
The device does not release any water.
Cause:
The water supply is interrupted.
Remedy:
Check the position of the cold water inlet angle valve and the stop valve, open fully if necessary.
Check the condition of the lines, repair kinks and damage if necessary.
If the malfunction persists, contact the service department.
The water quality is impaired (contamination, bad smell / taste).
Cause:
The filter capacity of a filter cartridge is exhausted or the change interval has been exceeded.
Remedy:
Replace the corresponding filter cartridge.
If the change interval has not yet been reached, first replace the left filter cartridge and vent the device, see Chapter Initial startup.
If the water quality is still affected, replace the middle filter cartridge in the same way.
If the water quality is still affected, replace the right filter cartridge in the same way.
The warranty conditions issued by our relevant sales company apply in all countries. We shall remedy possible malfunctions on your appliance within the warranty period free of cost, provided that a material or manufacturing defect is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.
(See overleaf for the address)
Device performance data | |
Water supply pressure | 0,1-0,4 (1-4) MPa (bar) |
Water supply temperature | 5-38 °C |
Ambient temperature | 4-40 °C |
Water dispenser (depending on supply pressure and filter status) | |
Filtered water | 2 l/min |
Dimensions and weights | |
Width | 377 mm |
Depth | 168 mm |
Height | 421 mm |
Weight | 5,66 kg |