IVM 100/36-3 (H)

99900080 (04/24)
99900080 (04/24)
Read these original instructions before using your device for the first time, adhere to the instructions contained therein and store them for later reference or subsequent owners.
Be sure to read the safety instructions no. 5.956-249.0 prior to the initial startup.
If the operating instructions and safety instructions are not observed, the device can be damaged and dangers could arise for users and other persons.
Notify the dealer immediately in the case of shipping damage.
Indication of an imminent threat of danger that will lead to severe injuries or even death.
Indication of a potentially dangerous situation that may lead to severe injuries or even death.
Indication of a potentially dangerous situation that may lead to minor injuries.
Indication of a potentially dangerous situation that may lead to damage to property.
Only trained personnel are permitted to use the device and the substances for which it is to be used, including the safe procedure for disposing of the vacuumed material.
An air exchange rate L must be present in the room when the exhaust gas is returned into the room. To remain within the required limit values, the volume flow of returned air must be no greater than 50% of the fresh air volume (room volume VR x air exchange rate LW). Without special ventilation measures, the following applies: LW=1h-1.
This device contains dust that is harmful to your health. Emptying and maintenance, including removal of the dust bag, may only be performed by technical specialists wearing suitable personal protective equipment.
Do not operate the device without the complete filtration system.
Observe the applicable safety instructions for the materials being vacuumed.
The device must not be used or stored outdoors in wet conditions.
Apply the parking brake at the steering roller to ensure a secure footing for the device. The device may move uncontrollably if the parking brake is open.
In case of longer breaks in operation and after use, switch off the device at the power switches and unplug the mains plug.
Risk of injury and damage in the event of a short-circuit or other electrical faults
Danger of electric shock, danger of burns
Switch off the device and unplug the mains plug.
The device is intended for:
Wet and dry cleaning of floor and wall surfaces
Vacuuming of moist or liquid substances
Vacuuming dry, non-flammable dusts from machines
Industrial usee.g. in storage and production areas
Commercial use, e.g. in hotels, schools, hospitals, factories, shops, offices, and rental companies.
Any other use constitutes improper use.
The device is not approved for crane loading.
The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.
Electrical and electronic devices contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which - if handled or disposed of incorrectly - can pose a potential danger to human health and the environment. However, these components are required for the correct operation of the device. Devices marked by this symbol are not allowed to be disposed of together with the household rubbish.
Current information on content materials can be found at: www.kaercher.de/REACH
Only use original accessories and original spare parts. They ensure that the appliance will run safely and fault-free.
Information on accessories and spare parts can be found in the Service area at www.kaercher.com.
Please note:
No accessories are included in the scope of delivery. The accessories must be ordered separately depending on the application.
The correct function of the device is only guaranteed by the prescribed nominal width of the suction hose (see chapter Technical data).
Spare parts and accessories are available from your dealer or from your KÄRCHER branch.
Check the contents for completeness when unpacking. In the event of shipping damage, please notify your dealer.
![]() | Dust bag (Order no. 9.989-607.0) |
![]() | Main filter (Order no. 6.907-651.0) |
![]() | H14 filter (Order no. 9.993-006.0) |
Danger from dust that is harmful to your health
Respiratory sicknesses through inhalation of dust.
Do not vacuum without correctly installed filter elements, otherwise a danger to health from increased fine dust emission is present.
Missing filter element
Damage to the suction motor
Do not vacuum without a filter element.
Bring the device into the working position.
Secure the device with the parking brakes.
Ensure that the suction head is fitted correctly.
Insert the suction hose (not included in the scope of delivery) into the suction connection.
Check the filling level in the dirt receptacle (see chapter Check the dirt receptacle filling level).
Empty the dirt receptacle if necessary (see chapter Emptying the dirt receptacle).
Fit the dust bag before vacuuming dry (see chapter Dry vacuuming)
Attach the desired accessories (not included in the scope of delivery) to the suction hose.
The dirt receptacle must be emptied when filled to the lower edge of the suction hose port on the dirt receptacle. The device does not switch off automatically if the maximum filling level is exceeded.
Check the dirt receptacle filling level regularly.
Danger from dust that is harmful to your health
Respiratory sicknesses through inhalation of dust.
Do not vacuum without correctly installed filter elements, otherwise a danger to health occurs from increased fine dust emission.
Danger due to fine dust entering
Risk of damage to the suction motor.
Never remove the main filter element when vacuuming.
The device is an industrial vacuum cleaner for vacuuming dry, non-flammable dusts.
Switching from wet to dry vacuuming
Risk of damage to the filter
Do not vacuum dry dust with a wet filter element because this clogs the filter and can make it unusable.
Allow the wet filter to dry completely or replace it with a dry filter before using the device for dry vacuuming.
Replace the filter if necessary.
Secure the device with the parking brakes.
Pull the bow handle up.
The dirt receptacle is unlocked and lowered.
Pull the dirt receptacle out of the device by the bow handle.
Fit the dust bag in the dirt receptacle and carefully position it against the container wall and the container floor.
Fold the edge of the dust bag over the edge of the dirt receptacle to the outside.
Improper handling when locking the dirt receptacle
Risk of crushing
Under no circumstances should you hold your hands between the dirt receptacle and filter ring or allow them to come close to the lifting mechanism while locking it.
Lock the dirt receptacle by operating the bow handle with both hands.
Fit the dirt receptacle and lock it with the bow handle.
Danger from dust that is harmful to your health
Respiratory sicknesses through inhalation of dust.
No dusts harmful to health may be vacuumed when performing wet vacuum cleaning.
Risk of damage if the dirt receptacle overflows
The dirt receptacle can fill within a few seconds and overflow when vacuuming large amounts of liquids.
Continuously monitor the filling level.
Remove the dust bag before wet vacuum cleaning (see chapter Removing the dust bag).
Secure the device with the parking brakes.
Pull the bow handle up.
The dirt receptacle is unlocked and lowered.
Pull the dirt receptacle out of the device by the bow handle.
Turn up the dust bag.
Seal the dust bag tightly with the cable tie.
Remove the dust bag.
Dispose of the dust bag in accordance with statutory regulations.
Improper handling when locking the dirt receptacle
Risk of crushing
Under no circumstances should you hold your hands between the dirt receptacle and filter ring or allow them to come close to the lifting mechanism while locking it.
Lock the dirt receptacle by operating the bow handle with both hands.
Fit the dirt receptacle and lock it with the bow handle.
Improper disposal of waste water
Environmental pollution
Observe the local waste water treatment regulations.
Dry the filter.
Clean the dirt receptacle with a moist cloth and dry it off.
Plug the mains plug into the socket.
Switch on the device via the suction turbine power switches.
Select the required suction power via the suction turbine power switch, starting with suction turbine 1. Always switch the suction turbines on and off one after the other.
Start the vacuuming process.
Clean the star pleated filter at regular intervals.
Switch off the device.
If dry suction material has been extracted, move the filter cleaning lever back and forth at least 5 times.
If this cleaning does not bring any improvement, remove the star pleated filter and wash or replace it (see chapter Care and maintenance).
Switch off the device via the suction turbine power switches.
Pull out the mains plug.
The inlet opening or the suction hose are closed.
Switch on the device via the suction turbine power switches.
Dedust the main filter (see chapter Dedusting the main filter).
Switch off the device via the suction turbine power switches.
Secure the device with the parking brakes.
Pull the bow handle up.
The dirt receptacle is unlocked and lowered.
Pull the dirt receptacle out of the device by the bow handle.
Empty the dirt receptacle. To do this, remove the dust bag if necessary (see Removing the dust bag).
The dirt receptacle can be lifted by crane at the handle. The maximum load for transport by crane is 50 kg.
Exceeding the permissible total weight
Risk of injury and damage
Observe the total weight of the dirt receptacle when transporting it by crane.
Do not overload the receptacle.
Observe the valid instructions for crane operation.
Improper handling when locking the dirt receptacle
Risk of crushing
Under no circumstances should you hold your hands between the dirt receptacle and filter ring or allow them to come close to the lifting mechanism while locking it.
Lock the dirt receptacle by operating the bow handle with both hands.
Fit the dirt receptacle and lock it with the bow handle.
Improper disposal of waste water
Environmental pollution
Observe the local waste water treatment regulations.
Vacuum the inside and outside of the device and clean with a moist cloth.
A vacuum cleaner with the same or better classification must be used for vacuuming the device.
If necessary, rinse the accessories (not included in the scope of delivery) with water and dry them.
Wind the mains cable onto the cable holders.
Store the device in a dry room and secure it against unauthorised use.
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during transportation.
Release the parking brakes and push the device by the push handle.
Grasp the device by the chassis and the push handle for loading.
Secure the device against slipping and tipping over when transporting in vehicles.
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during storage.
Store the device indoors only.
Inadvertently starting up device, touching live components
Risk of injury, electric shock
Switch off the device before performing any work on the device.
Remove the mains plug.
Danger from dust that is harmful to your health
Respiratory sicknesses through inhalation of dust.
Wear a breathing protection mask of class P2 or higher and disposable clothing when performing maintenance work (e.g. filter change).
Inadequate filtration
Respiratory sicknesses through inhalation of dust.
The effectiveness of the filtration of the device can be tested by the test method specified in EN 60 335-2-69 22.AA.201.2.
Danger from dust that is harmful to your health
Respiratory sicknesses through inhalation of dust.
Safety devices providing hazard protection must be checked for correct safety-related functionality at least annually by the manufacturer or an appropriately instruction person, e.g. absence of leaks, filter damage, functionality of the monitoring devices.
Care agents containing silicone
These can attach plastic components.
Do not use care agents containing silicone for cleaning.
Dust extraction machines are safety devices for the prevention or elimination of hazards according to the German BGV A1.
For servicing performed by the user, the device must be disassembled, cleaned and maintained only to the degree that this is possible without presenting a danger to the maintenance personnel and other persons. Suitable precautionary measures include detoxification before disassembly. Make provisions for local forced ventilation at the location where the device is to be disassembled, for cleaning the maintenance surface and to ensure adequate protection for the personnel.
The exterior of the device should be detoxified by vacuuming and wiped clean, or treated with sealant before being removed from the hazardous area. All unit parts must be regarded as contaminated when they are taken from the hazardous area. Suitable measures must be taken to prevent distribution of the dust.
All contaminated objects resulting from maintenance and repair work that cannot be satisfactorily cleaned must be correctly disposed of. Such objects must be disposed of in sealed bags in accordance with the applicable regulations for the disposal of this type of waste.
The suction hose ports are to be closed using the sealing plugs during transport and maintenance of the device.
Note that you can carry out simple maintenance and care work yourself.
Clean the surface of the device and the interior of the container regularly with a moist cloth.
Have the device regularly inspected according to the respective national accident prevention regulations. Maintenance work as specified by the manufacturer must be performed by a technically qualified person at the specified regular intervals and in accordance with the applicable regulations and safety requirements. Work on electrical components may only be performed by a qualified electrician. Please contact a KÄRCHER branch office if you have any questions.
Switch off the device.
Pull out the mains plug.
Unlock and remove the suction head.
Unlock and remove the spacer.
Remove the contaminated star pleated filter.
Immediately after removing the contaminated star pleated filter from the unit, place it in a bag and seal the bag tightly.
Dispose of the contaminated star pleated filter according to legal requirements.
Remove any dirt deposits from the clean air side.
Check the sealing ring for damage.
Insert the new star pleated filter:
Pull the new star pleated filter over the filter vibrator on the spacer such that the vibrating elements are aligned centrally in the filter bags.
Place the spacer with star pleated filter and filter vibrator on the filter ring.
Lock the spacer.
Fit and lock the suction head.
Secure the device with the parking brakes.
Switch off the device at the power switches.
Pull out the mains plug.
Unlock and remove the suction head.
Unscrew the hexagon screw anticlockwise using a suitable tool.
Remove the seals and the filter from the suction head.
Remove any dirt deposits from the clean air side.
Fit the new H filter in the reverse order. Make sure that the seals are correctly seated.
Apply a suitable agent (e.g. Loctite 243) to the thread of the hexagon screw to prevent unintentional loosening.
Tighten the hexagon screw clockwise.
Fit and lock the suction head.
Secure the device with the parking brakes.
Pull the bow handle up.
The dirt receptacle is unlocked and lowered.
Pull the dirt receptacle out of the device by the bow handle.
Turn up the dust bag.
Seal the dust bag tightly with the cable tie.
Remove the dust bag.
Dispose of the dust bag in accordance with statutory regulations.
Insert the new dust bag in the dirt receptacle and carefully place it against the container wall and the container floor.
Fold the edge of the dust bag over the edge of the dirt receptacle to the outside.
Improper handling when locking the dirt receptacle
Risk of crushing
Under no circumstances should you hold your hands between the dirt receptacle and filter ring or allow them to come close to the lifting mechanism while locking it.
Lock the dirt receptacle by operating the bow handle with both hands.
Fit the dirt receptacle and lock it with the bow handle.
Unintentional start-up of the device / electric shock
Unintentional start-up of the suction motor can cause injuries. Voltage present on electrical parts can cause an electric shock.
Switch off the device and unplug the mains plug before performing any work on the device.
Have all checks and work on electrical parts performed by an qualified technician.
The device must be switched off immediately in the event of a malfunction. The malfunction must be eliminated before switching the device on again.
If the malfunction cannot be corrected, the device must be checked by the Customer Service department.
Suction turbine does not start up
Remedy:
Check the socket and the power supply fuse.
Check the mains cable and the mains plug of the device.
Switch the device on.
Suction power decreases
Remedy:
Remove the blockages from the suction nozzle, the suction pipe or the suction hose.
Replace the filled dust bag (see chapter Replace dust bag).
Check that the suction head and the dirt receptacle are correctly seated.
Dedust the main filter (see chapter Dedusting the main filter).
Check the seating of the filter and correct if necessary.
Replace the main filter (see chapter Replacing the main filter).
Escaping dust when vacuuming
Remedy:
Check the seating of the filter and correct if necessary.
Dedust the main filter (see chapter Dedusting the main filter).
Replace the main filter (see chapter Replacing the main filter).
At the end of its service life, the device is to be disposed of in accordance with statutory regulations.
The warranty conditions issued by our relevant sales company apply in all countries. We shall remedy possible malfunctions on your appliance within the warranty period free of cost, provided that a material or manufacturing flaw is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.
Further information can be found at: www.kaercher.com/dealersearch
Further warranty information (if available) can be found in the service area of your local Kärcher website under "Downloads".
Electrical connection | |
Mains voltage | 220-240 V |
Phase | 1 ~ |
Power frequency | 50-60 Hz |
Nominal power | 3150 W |
Maximum power | 3600 W |
Protection type | IPX4 |
Protection class | I* |
Maximum permissible mains grid impedance | 0.195+j0.122 Ω |
Dimensions and weights | |
Typical operating weight | 81 kg |
Length x width x height | 1020 x 680 x 1890 mm |
Filter area of main filter | 2.24 m2 |
Filter area of the H filter | 3.5 m2 |
Ambient conditions | |
Storage temperature | -10-40 °C |
Device performance data | |
Container capacity | 100 l |
Vacuum (with pressure relief valve) | 25.4 kPa |
Air quantity | 3x 74 l/s |
Suction hose connection | DN70 |
Nominal width of the suction hose | DN40/50/70 |
Main filter order number | 6.907-651.0 |
Main filter order number | 9.993-006.0 |
Determined values in acc. with EN 60335-2-69 | |
Hand-arm vibration value | < 2.5 m/s2 |
K uncertainty | 0.2 m/s2 |
Sound pressure level LpA | 79 dB(A) |
Uncertainty KpA | 2 dB(A) |
Mains cable | |
Type | H07RN-F 3G1.5 mm2 |
Part number | 6.650-035.0 |
Cable length | 10 m |
EU Declaration of Conformity |
We hereby declare that the machine described below complies with the relevant basic safety and health requirements in the EU Directives, both in its basic design and construction as well as in the version placed in circulation by us. This declaration is invalidated by any changes made to the machine that are not approved by us.
Product: Dry vacuum cleaner
Product: Wet/dry vacuum cleaner
Type: 9.989-xxx
Currently applicable EU Directives2006/42/EC (+2009/127/EC)
2014/30/EU
2011/65/EU
Harmonised standards usedEN 60335-1
EN 60335-2-69
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 2015
EN IEC 61000-3-2: 2019
EN 61000-3-3: 2013 + A1: 2019
EN 61000-3-11: 2000
EN 62233: 2008
EN IEC 63000: 2018
National standards used-
The signatories act on behalf of and with the authority of the Executive Board.
Documentation supervisor:
A. Haag
Kärcher Industrial Vacuuming GmbH
Robert-Bosch-Straße 4-8
73550 Waldstetten (Germany)
Ph.: +49 7171 94888-0
Fax: +49 7171 94888-528
Waldstetten, 24/04/01
Declaration of Conformity (UK) |
We hereby declare that the product described below complies with the relevant provisions of the following UK Regulations, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the product is modified without our prior approval.
Product: Dry vacuum cleaner
Product: Wet/dry vacuum cleaner
Type: 9.989-xxx
Currently applicable UK RegulationsS.I. 2008/1597 (as amended)
S.I. 2016/1091 (as amended)
S.I. 2012/3032 (as amended)
Designated standards usedEN 60335-1
EN 60335-2-69
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 2015
EN IEC 61000-3-2: 2019
EN 61000-3-3: 2013 + A1: 2019
EN 61000-3-11: 2000
EN 62233: 2008
EN IEC 63000: 2018
National standards used-
The signatories act on behalf of and with the authority of the Executive Board.
Documentation supervisor:
A. Haag
Kärcher Industrial Vacuuming GmbH
Robert-Bosch-Straße 4-8
73550 Waldstetten (Germany)
Ph.: +49 7171 94888-0
Fax: +49 7171 94888-528
Waldstetten, 24/04/01
2-2-HC-A5-GS-awx2508