LogoBooster Pump for GardenBP 4.500 GardenBP 5.000 GardenBP 6.000 GardenBP 7.000 Garden
  • Safety instructions
    • Hazard levels
    • General safety instructions
    • Risk of electric shock
    • Operation
    • Care and maintenance
    • Transport
  • Intended use
    • Permissible feed fluids
    • Improper use
  • Environmental protection
  • Accessories and spare parts
  • Scope of delivery
  • Warranty
  • Description of the device
  • Startup
    • Before initial startup
      • Preparation
  • Operation
    • Ending operation
  • Care and maintenance
    • Rinse
  • Transport
    • Manual transport
    • Transport in vehicles
  • Storage
    • Storing the device
  • Special accessories
  • Troubleshooting guide
    • Pump is running, but not delivering

    • The pump does not start up, or stops suddenly during operation

    • The pump capacity drops or is too low

  • Specifications
    • BP 4.500 Garden
      BP 4.500 Garden Set Plus
    • BP 5.000 Garden
      BP 5.000 Garden Set Plus
    • BP 6.000 Garden
      BP 6.000 Garden Set Plus
    • BP 7.000 Garden
  • Characteristic curves
  • Declaration of Conformity

      Booster Pump for Garden
      BP 4.500 Garden
      BP 5.000 Garden
      BP 6.000 Garden
      BP 7.000 Garden

      59910860 (12/22)

      Safety instructions

      Read this safety chapter and these original instructions before using the device for the first time. Act in accordance with them. Keep the original instructions for future reference or for future owners.

      • In addition to the notes in the operating instructions, you also need to take into consideration the general safety regulations and accident prevention guidelines applicable by law.

      • Warnings and information notices attached to the device provide important information for hazard-free operation.

      Hazard levels

      DANGER

      Indication of an imminent threat of danger that will lead to severe injuries or even death.

      WARNING

      Indication of a potentially dangerous situation that may lead to severe injuries or even death.

      CAUTION

      Indication of a potentially dangerous situation that may lead to minor injuries.

      ATTENTION

      Indication of a potentially dangerous situation that may lead to damage to property.

      General safety instructions

      DANGER

      Risk of asphyxiation. Keep packaging film out of the reach of children.

      WARNING

      Persons with reduced physical, sensory or mental capabilities and persons lacking experience and knowledge may only use the appliance if they are properly supervised, have been instructed on use of the appliance safely by a person responsible for their safety, and understand the resultant hazards involved.

      WARNING

      Always disconnect the device from the power supply before assembling, disassembling or cleaning.

      WARNING

      Children must be supervised to prevent them from playing with the appliance.

      WARNING

      Children must not operate the device.

      WARNING

      Cleaning and user maintenance may not be carried out by children.

      Risk of electric shock

      DANGER

      Never touch the mains plug and socket with wet hands.

      DANGER

      The voltage indicated on the type plate must match the voltage of the power source.

      DANGER

      Install electrical plug connections only in areas that are protected against flooding.

      DANGER

      Operate pumps at swimming pools, garden ponds and fountains only via a fault current protection switch with a nominal current no greater than 30 mA and with a protective contact (ground).

      DANGER

      In Austria, pumps used with swimming pools and garden ponds that are permanently connected to the mains supply must be supplied via an isolating transformer approved according to the Austrian Electrotechnical Association standard ÖVE B/EN 60555 Parts 1 to 3, where the nominal secondary output voltage of the transformer must not exceed 230 V.

      DANGER

      Only operate the device via a fault current protection switch (maximum 30 mA).

      DANGER

      The mains plug and coupling of the extension cable must be water tight and may not be placed in water. The coupling may not be on the floor. Use cable drums to ensure that the sockets are at least 60 mm above the floor.

      DANGER

      You may not operate the pump when persons are in the swimming pool or garden pond.

      WARNING

      Only connect the device to an electrical connection that has been installed by a qualified electrician. It is essential that you adhere to the national regulations for this.

      WARNING

      When using the pump on swimming pools, garden ponds or fountains, maintain a minimum distance of 2 m and secure the pump against slipping into the water.

      WARNING

      Do not use the pump as a submersible pump.

      WARNING

      Check that the mains connection cable with mains plug is undamaged each time before using the device. To avoid any possible danger, a damaged mains connection cable must be immediately replaced by the manufacturer, or the authorised customer service department or a qualified electrician.

      WARNING

      Do not damage the power supply and extension cable by running over it, crushing or yanking it or similar. Protect the power supply cable from heat, oil and sharp edges.

      WARNING

      Unsuitable electrical extension cables can be dangerous. Only use approved and appropriately marked electrical extension cables with a sufficient cable cross section for outdoors.

      CAUTION

      Always fully unwind the extension cable from the cable drum.

      CAUTION

      Do not carry/transport the device using the power supply cable.

      CAUTION

      Do not pull the mains plug out the socket using the power supply cable.

      ATTENTION

      Do not operate the device continuously in the rain or under wet weather conditions.

      ATTENTION

      Ensure that the unit is stable and protected against floods.

      Operation

      DANGER

      Risk of explosion

      • Do not pump corrosive, highly flammable or explosive liquids, e.g. petroleum, petrol, acids or nitro thinner.

      • Do not operate the unit in a flammable or explosive environment

      DANGER

      The device is pressurised. Open the shut-off valve on the pressure side via the drain tap (available from specialist dealers) and drain the system before opening the filler or drain caps or before disconnecting any pipe connections.

      CAUTION

      Accidents or damage due to the device falling over. Before all actions with or on the device, you must make sure that it is stable.

      CAUTION

      Water that has been pumped with this unit is not drinking water.

      ATTENTION

      Do not convey fats, oils and salt water.

      ATTENTION

      Do not pump waste water from sanitary facilities or muddy water with a lower flowing ability than clear water.

      ATTENTION

      Do not pump water that has a temperature higher than 35°C.

      ATTENTION

      Pumps without any note that they are protected against frost must not be left outside in freezing weather.

      ATTENTION

      Do not operate the device during frost conditions.

      Care and maintenance

      WARNING

      Switch off the device immediately and remove the mains plug before performing any care and service work.

      CAUTION

      Have repair work, installation of spare parts and work on electrical components carried out by the authorised customer service only.

      Transport

      CAUTION

      Accidents or damage due to the device falling over. Before all actions with or on the device, you must make sure that it is stable.

      CAUTION

      Risk of accidents and injuries. Take into account the weight of the device for transportation and storage. See chapter Technical data in the operating instructions.

      Intended use

      Please observe the requirements of EN 1717 when connecting this product to the drinking water network and contact your sanitation specialists if you have any questions.

      This device has been developed for private use and is not intended for the load imposed by commercial use.

      The device is primarily intended for use in the garden and provides constant pressure for garden watering.

      When connecting sprinklers, a maximum of the following areas can be irrigated:

      • BP 4.500 Garden: 400 m2

      • BP 5.000 Garden: 550 m2

      • BP 6.000 Garden: 900 m2

      • BP 7.000 Garden: 1000 m2

      CAUTION

      Risk of injury!

      Risk of injury from toxic substances.

      Do not drink water that has been pumped by the pump!

      Permissible feed fluids

      Permissible feed fluids:

      • Processed water

      • Well water

      • Spring water

      • Rain water

      • Swimming pool water with intended dosage of additives

      The temperature of the delivered liquid must not exceed 35 °C.

      Improper use

      Note

      The manufacturer accepts no liability for possible damage caused by improper use or incorrect operation.

      Environmental protection

      The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.

      Electrical and electronic devices contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which - if handled or disposed of incorrectly - can pose a potential danger to human health and the environment. However, these components are required for the correct operation of the device. Devices marked by this symbol are not allowed to be disposed of together with the household rubbish.

      Notes on the content materials (REACH)

      Current information on content materials can be found at: www.kaercher.de/REACH

      Accessories and spare parts

      Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.

      Information on accessories and spare parts can be found at www.kaercher.com.

      Scope of delivery

      The scope of delivery for the appliance is shown on the packaging. Check the contents for completeness when unpacking. If any accessories are missing or in the event of any shipping damage, please notify your dealer.

      Warranty

      The warranty conditions issued by our sales company responsible apply in all countries. We shall remedy possible malfunctions on your device within the warranty period free of cost, provided that a material or manufacturing defect is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.

      (See overleaf for the address)

      Description of the device

      The maximum amount of equipment is described in these operating instructions. Depending on the model used, there are differences in the scope of delivery (see packaging).


      1. Cap, 2-way connection adapter
      2. 2-way connection adapter for pumps G 1 (not included with BP 4.500 Garden)
      3. Connection adapter for pumps G 1 (included twice with BP 4.500 Garden)
      4. Sealing plug
      5. Connection G 1 (33.3 mm) suction line (inlet)
      6. Filling nozzle with cap
      7. Connection G 1 (33.3 mm) pressure line (outlet)
      8. ON/OFF switch
      9. Water drain valve
      10. **Tap connection G 1
      11. **Coupling with Aqua Stop
      12. **Coupling
      13. **Syringe
      14. *Suction hose set incl. 3.5 m ready-to-connect, vacuum-proof spiral hose with suction filter and backflow stop
      15. **Garden hose 1/2″ 20 m
      16. Power supply cable with plug

      * Only accessories included with Set and Set Plus.

      ** Only accessories included with Set Plus.

      Startup

      We recommend using only original Kärcher suction hoses, filter components and hose connections. Using components from other manufacturers can lead to malfunctions when sucking the feed fluid, especially when using bayonet connection systems.

      Before initial startup

      Preparation

      • Remove the sealing plug.

      • Screw the connection adapter into the suction connection of the pump (inlet). Manually tighten.

      • Connect a vacuum-tight suction hose


        Note

        If the water is dirty, we recommend fitting a pre-filter (seeSpecial accessories) between the check valve and the suction hose.


        Note

        To shorten the re-suction time, use a suction hose with backflow stop. This prevents the suction hose from emptying after use (seeSpecial accessories).

      • Screw the connection adapter into the pressure connection of the pump (outlet). Manually tighten.


      • Open the filling nozzle cap.


      • Fill the pump with water until it overflows.


      Operation

      1. Plug the mains plug into a mains socket.

      2. Switch the device on with the ON/OFF switch.

      3. To shorten the suction time, raise the pressure hose approx. 1 m.


      4. Wait until the pump simultaneously sucks and delivers.

        CAUTION

        Danger due to dry running

        Dry running damages the pump.

        Do not let the pump run dry!

      5. Do not leave the pump unattended during operation.

      ATTENTION

      Risk of injury. The system is pressurised!

      Risk of injury.

      (for pressure see chapter "Technical data")

      Ending operation

      1. Switch off the device at the ON/OFF switch.

      2. Pull the mains plug out of the socket.

      Care and maintenance

      DANGER

      Danger of electric shock.

      Always switch the device off and disconnect the mains plug before working on the device.

      The device is maintenance-free.

      Rinse

      Note

      Rinse the pump with clear water after each use when pumping water with additives.

      Transport

      CAUTION

      Risk of injury

      Risk of injury from falling device.

      When transporting the device, observe the weight of the device (see chapter Specifications) and secure it accordingly when transporting it in vehicles.

      Manual transport

      1. Roll up the cable.

      2. Lift and carry the device by the carrying handle.

      Transport in vehicles

      1. Secure the device against slipping and tipping over.

      CAUTION

      Risk of injury

      Risk of injury from falling device.

      When transporting the device, observe the weight of the device (see technical data) and secure it accordingly when transporting it in vehicles.

      Storage

      CAUTION

      Failure to observe the weight

      Risk of injury and damage

      Be aware of the weight of the device during storage.

      1. Store the device in a frost-protected place.

      Storing the device

      1. Depressurise the device by opening the water removal connected to the pressure side (e.g. opening the garden sprayer).

      2. Empty the hoses.

      3. Remove suction line and pressure line.

      4. Drain the pump via the water drain valve.


      5. Store the device in a frost-protected place.

      Special accessories

      You will find the possible special accessories on the last page of these operating instructions.

      Troubleshooting guide

      Malfunctions often have simple causes that you can remedy yourself using the following overview. When in doubt, or in the case of malfunctions not mentioned here, please contact your authorised Customer Service.

      • Pump is running, but not delivering 

      • The pump does not start up, or stops suddenly during operation 

      • The pump capacity drops or is too low 

      Pump is running, but not delivering

      Cause:

      Air is in the pump.

      Remedy:

      1. Check for correct startup (see chapter Preparation and Operation ).

      Cause:

      Dirt particles block the suction area.

      Remedy:

      1. Pull the mains plug out of the socket.

      2. Clean the suction area.

      Cause:

      The suction hose or the connection adapter is not correctly screwed in.

      Remedy:

      1. Check that the seals are fitted correctly.

      2. Manually tighten the suction hose and connection adapter.

      Cause:

      The pre-filter is clogged.

      Remedy:

      1. Clean the pre-filter.

      The pump does not start up, or stops suddenly during operation

      Cause:

      The power supply is disconnected.

      Remedy:

      1. Check the fuses and the electrical connections.

      The pump capacity drops or is too low

      Cause:

      The suction area is clogged.

      Remedy:

      1. Pull the mains plug out of the socket.

      2. Clean the suction area.

      Cause:

      The delivery rate of the pump depends on the delivery head and the connected periphery.

      Remedy:

      1. Observe the max. delivery head (see chapter Specifications), select a different hose diameter or a different hose length if necessary.

      Cause:

      The cross-section on the pressure side is narrowed, e.g. due to the valve/ball tap not being fully open.

      Remedy:

      1. Open the valve/ball tap completely.

      Cause:

      The hose is kinked on the pressure side.

      Remedy:

      1. Eliminate the kink points in the hose.

      Cause:

      The pre-filter is clogged.

      Remedy:

      1. Clean the pre-filter.

      Specifications

      • BP 4.500 Garden BP 4.500 Garden Set Plus 

      • BP 5.000 Garden BP 5.000 Garden Set Plus 

      • BP 6.000 Garden BP 6.000 Garden Set Plus 

      • BP 7.000 Garden  

      BP 4.500 Garden
      BP 4.500 Garden Set Plus

        
      Mains voltage
      230-240 V
      Power frequency
      50 Hz
      Nominal power
      550 W
      Maximum flow rate
      4500 l/h
      Suction height (max.)
      8 m
      Pressure (max.)
      0,36 (3,6) MPa (bar)
      Delivery height (max.)
      35 m
      Delivery temperature (max.)
      35,0 °C
      Particle size (max.) of permissible feed fluids
      1 mm
      Pump type
      Jet
        
      Sound pressure level LpA
      56 dB(A)
      Guaranteed sound power level LWA
      71 dB(A)
      Dimensions and weights
      Weight (without accessories)
      6,4 kg

      BP 5.000 Garden
      BP 5.000 Garden Set Plus

        
      Mains voltage
      230-240 V
      Power frequency
      50 Hz
      Nominal power
      650 W
      Maximum flow rate
      5000 l/h
      Suction height (max.)
      8 m
      Pressure (max.)
      0,40 (4,0) MPa (bar)
      Delivery height (max.)
      40 m
      Delivery temperature (max.)
      35,0 °C
      Particle size (max.) of permissible feed fluids
      1 mm
      Pump type
      Jet
        
      Sound pressure level LpA
      58 dB(A)
      Guaranteed sound power level LWA
      73 dB(A)
      Dimensions and weights
      Weight (without accessories)
      7,0 kg

      BP 6.000 Garden
      BP 6.000 Garden Set Plus

        
      Mains voltage
      230-240 V
      Power frequency
      50 Hz
      Nominal power
      1000 W
      Maximum flow rate
      6000 l/h
      Suction height (max.)
      8 m
      Pressure (max.)
      0,45 (4,5) MPa (bar)
      Delivery height (max.)
      45 m
      Delivery temperature (max.)
      35,0 °C
      Particle size (max.) of permissible feed fluids
      1 mm
      Pump type
      Jet
        
      Sound pressure level LpA
      69 dB(A)
      Guaranteed sound power level LWA
      84 dB(A)
      Dimensions and weights
      Weight (without accessories)
      9,7 kg

      BP 7.000 Garden

        
      Mains voltage
      230-240 V
      Power frequency
      50 Hz
      Nominal power
      1100 W
      Maximum flow rate
      7000 l/h
      Suction height (max.)
      8 m
      Pressure (max.)
      0,5 (5,0) MPa (bar)
      Delivery height (max.)
      50 m
      Delivery temperature (max.)
      35,0 °C
      Particle size (max.) of permissible feed fluids
      1 mm
      Pump type
      Jet
        
      Sound pressure level LpA
      68 dB(A)
      Guaranteed sound power level LWA
      83 dB(A)
      Dimensions and weights
      Weight (without accessories)
      10,0 kg

      Characteristic curves



      Declaration of Conformity

      EU Declaration of Conformity

      We hereby declare that the machine described below complies with the relevant basic safety and health requirements in the EU Directives, both in its basic design and construction as well as in the version placed in circulation by us. This declaration is invalidated by any changes made to the machine that are not approved by us.

      Product: Pump

      Type: 1.645-xxx

      Currently applicable EU Directives

      2006/42/EC (+2009/127/EC)

      2014/30/EU

      2000/14/EC

      2011/65/EU

      2009/125/EC

      Commission Regulation(s)

      (EU) 2019/1781

      Harmonised standards used

      EN 60335-1

      EN 60335-2-41

      EN 62233: 2008

      EN 55014-1: 2017 + A11: 2020

      EN 55014-2: 1997+A1: 2001+A2: 2008

      EN 61000-3-2: 2014

      EN 61000-3-3: 2013

      EN IEC 63000: 2018

      Conformity evaluation procedure used

      2000/14/EC: Annex V

      Sound power level dB(A)

      BP 4.500 Garden

      Measured: 68

      Guaranteed: 71

      BP 5.000 Garden

      Measured: 70

      Guaranteed: 73

      BP 6.000 Garden

      Measured: 81

      Guaranteed: 84

      BP 7.000 Garden

      Measured: 81

      Guaranteed: 83

      The signatories act on behalf of and with the authority of the company management.


      Documentation supervisor:

      S. Reiser

      Alfred Kärcher SE & Co. KG

      Alfred-Kärcher-Str. 28 - 40

      71364 Winnenden (Germany)

      Ph.: +49 7195 14-0

      Fax: +49 7195 14-2212

      Winnenden, 2021/06/01

      Declaration of Conformity (UK)

      We hereby declare that the product described below complies with the relevant provisions of the following UK Regulations, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the product is modified without our prior approval.

      Product: Pump

      Type: 1.645-xxx

      Currently applicable UK Regulations

      S.I. 2008/1597 (as amended)

      S.I. 2016/1091 (as amended)

      S.I. 2001/1701 (as amended)

      S.I. 2012/3032 (as amended)

      S.I. 2010/2617 (as amended)

      Commission Regulation(s)

      (EU) 2019/1781

      Designated standards used

      EN 60335-1

      EN 60335-2-41

      EN 62233: 2008

      EN 55014-1: 2017 + A11: 2020

      EN 55014-2: 1997+A1: 2001+A2: 2008

      EN 61000-3-2: 2014

      EN 61000-3-3: 2013

      EN IEC 63000: 2018

      Applied conformity assessment procedure

      S.I. 2001/1701 (as amended): Schedule 8

      Sound power level dB(A)

      BP 4.500 Garden

      Measured: 68

      Guaranteed: 71

      BP 5.000 Garden

      Measured: 70

      Guaranteed: 73

      BP 6.000 Garden

      Measured: 81

      Guaranteed: 84

      BP 7.000 Garden

      Measured: 81

      Guaranteed: 83

      The signatories act on behalf of and with the authority of the company management.


      Documentation supervisor:

      S. Reiser

      Alfred Kärcher SE & Co. KG

      Alfred-Kärcher-Str. 28 - 40

      71364 Winnenden (Germany)

      Ph.: +49 7195 14-0

      Fax: +49 7195 14-2212

      Winnenden, 2021/06/01