LogoNT 75/1 Me Ec M Z22
  • General notes
  • Environmental protection
  • Intended use
  • Description of the device
  • Symbols on the device
    • Dust class
    • Zone 22, fleece filter bag
  • Safety instructions
    • Behavior in the event of an emergency
  • Preparation
  • Starting up
    • Automatic suction power monitor
    • Anti-static system
    • Dry vacuuming
      • Installing the fleece filter bag
    • Wet vacuum cleaning
      • Installing the squeegees
      • Closing the suction connection
      • Removing the fleece filter bag
      • General
  • Operation
    • Each time before use
    • Rotary switch
    • Switching on the device
    • Cleaning mode
    • Switching off the device
    • Each time after use
    • Folding the push handle in/out
    • Storing the device
  • Transport
  • Storage
  • Care and service
    • Replacing the flat fold filter
    • Change the candle filter
    • Changing the fleece filter bag
    • Cleaning the cooling air filter
    • Changing the cooling air filter
    • Cleaning the electrodes
  • Troubleshooting guide
    • Suction turbine does not start up

    • Suction turbine switches off

    • Suction turbine does not switch on again after emptying the container

    • Suction force decreases

    • Escaping dust when vacuuming

    • The automatic switch-off mechanism (wet vacuum cleaning) does not trigger

    • "Vacuum pressure" indicator light flashes red

  • Customer Service department
    • Suction turbine does not start up

    • Suction turbine switches off

    • Suction turbine does not switch on again after emptying the container

    • Suction force decreases

    • Escaping dust when vacuuming

    • The automatic switch-off mechanism (wet vacuum cleaning) does not trigger

    • "Vacuum pressure" indicator light flashes red

  • Disposal
  • Warranty
  • Accessories and spare parts
  • Declaration of Conformity
  • Technical data

      NT 75/1 Me Ec M Z22

      59793760 (04/24)

      General notes

      these original instructions and the enclosed safety notes no. 59562490 before using the device for the first time. Proceed accordingly.

      Keep both books for future reference or for future owners.

      • If the operating instructions and safety instructions are not observed, the device can be damaged and dangers could arise for users and other persons.

      • Notify the dealer immediately in the case of shipping damage.

      • When unpacking, check the package contents for missing accessories or signs of damage.

      Environmental protection

      The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.

      Electrical and electronic devices contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which - if handled or disposed of incorrectly - can pose a potential danger to human health and the environment. However, these components are required for the correct operation of the device. Devices marked by this symbol are not allowed to be disposed of together with the household rubbish.

      Notes on the content materials (REACH)

      Current information on content materials can be found at: www.kaercher.de/REACH

      Intended use

      • This wet/dry vacuum cleaner is designed to remove dry dirt and liquids.

      • Operation with flat fold filter The device is suitable for vacuuming dry, conductive, combustible dusts in zone 22 dust class M.

      • Operation with candle filter (special accessory, order number 2.414-000.0): The device is suitable for vacuuming dry, conductive, combustible dusts in zone 22 dust class L. For vacuuming class M dust, a fleece filter bag must also be used. A suction hose with a length of 8 metres is not suitable.

      • The device is not suitable for extracting metallic dusts that lead to hydrogen formation on contact with water.

      • Type 22 devices are suitable for holding combustible dust in zone 22. They are not suitable for connection to dust-generating machines.

      • Type 22 devices are not suitable for the intake of dusts or liquids with high risk of explosion and for mixtures of combustible dusts with liquids.

      • The vacuum cleaner is intended for the removal of combustible dusts in potentially explosive environments classified as Zone 22.

      • This device is suitable for commercial use,e.g. in production areas in industry and crafts, in warehouses, in transport and in agriculture.

      • Any other use will be regarded as improper use.

      Description of the device


      1. Electrodes
      2. Suction hose
      3. Push handle fastening screw
      4. Suction head lock
      5. Filter casing, left
      6. Cooling air filter, left
      7. Dirt receptacle
      8. Recessed grip
      9. Steering roller with parking brake
      10. Suction hose port
      11. Chassis handle
      12. Floor nozzle
      13. Chassis
      14. Plug
      15. Suction pipe
      16. Cooling air filter, right
      17. Filter casing, right
      18. Suction head
      19. Rotary switch
      20. "Vacuum pressure" indicator light
      21. Carrying handle
      22. Filter cover
      23. Fastening eyelet
      24. Hose hook
      25. Push handle, adjustable
      26. Angle piece
      27. Rest for floor nozzle
      28. Tilting aid
      29. Holder for crevice nozzle
      30. Suction pipe holder
      31. Filter frame
      32. Power cable
      33. Flat fold filter
      34. Filter cover handle
      35. Type plate

      Symbols on the device

      Dust class

      WARNING: This device contains dusts that are harmful to your health. Emptying and maintenance, including removal of the dust bag, may only be performed by appropriately trained personnel wearing suitable personal protective equipment. Do not switch on until the entire filter system is installed. Check the function of the volume flow control when the device is switched on.

      Zone 22, fleece filter bag

       
      Do not vacuum any sources of ignition! Suitable for vacuuming inflammable dusts of dust explosion classes in zone 22.
       
      Fleece filter bag
      Order number
      2.885-753.0

      Safety instructions

      DANGER

      Risk of injury, explosion and damage

      Observe the following safety instructions when handling the device.

      • The electrical connection (mains plug) must be made outside the hazardous area (Zone 22).

      • The included accessories are electrically conductive. Only the accessories listed in the appendix (standard accessories / special accessories) may be used!

      • Do not vacuum without filter elements in place, otherwise the suction motor will be damaged and there will be a health risk due to increased fine dust emissions!

      • Observe the safety regulations for the materials being vacuumed. During proper/improper operation, parts (e.g. air outlet) of the vacuum cleaner can reach up to 105 °C.

      • The minimum ignition temperature (MIT) of the dust cloud is ≥160 °C and the MIT of dust with a dust thickness of 5 mm is ≥180 °C.

      • The use of an extension cord is prohibited.

      Behavior in the event of an emergency

      DANGER

      Risk of injury and damage in the event of a short-circuit or other electrical faults

      Danger of electric shock, danger of burns

      Switch off the device and unplug the mains plug.

      Preparation

      1. Unpack the device and install the accessories.


      Starting up

      WARNING

      Danger from dust that is harmful to your health

      Respiratory sicknesses through inhalation of dust.

      Do not vacuum without correctly installed filter elements, otherwise a danger to health from increased fine dust emission is present.

      Note

      The device is not suitable for the vacuuming of dusts with extremely low minimum ignition energy (ME < 1 mJ),e.g. toner, mesh, aluminium powder, lead acid suitable.

      1. Bring the device into the working position and secure it with the parking brake if necessary.

      2. Plug the suction hose into the suction hose port.

      3. Check the filling level in the dirt receptacle before starting work and empty the receptacle if necessary.

      4. Attach the desired accessory.

      Automatic suction power monitor

      The device is equipped with a suction power monitor. If the air speed in the suction hose drops below a speed of 20 m/s, the "vacuum pressure" indicator light flashes red (see Help with malfunctions).

      Note

      The indicator light can light up intermittently during normal operation (e.g.when working with a floor nozzle) when the air quantity is reduced (cross-section reduction) and the vacuum pressure increases as a result.

      Note

      In these cases, however, it is not a defect, but an indication that the air quantity has reduced and the vacuum pressure has increased, as indicated above.

      Anti-static system

      Static charges are discharged through the earthed connection nozzles. This prevents sparking and electric shocks with electrically conducting accessories (included in the scope of delivery).

      Dry vacuuming

      • The device is fitted with a fleece filter bag with cap, order no. 2.885-753.0 (5 pieces).

      Note

      All types of dust up to dust class M can be vacuumed with this device. The use of a dust collection bag (for order no. see filter systems) is required by law when vacuuming M-dusts. L-dusts can be vacuumed directly into the dust collection container.

      Note

      The device is an industrial vacuum cleaner for vacuuming dry, conducting, combustible dusts with workplace limit values (AGW) larger than 0.1 mg/m3.

      WARNING

      Danger from dust that is harmful to your health

      Respiratory sicknesses through inhalation of dust.

      Do not vacuum without a flat fold filter or candle filter (special accessory) and fleece filter bag, otherwise a danger to health from increased fine dust emission is present.

      Installing the fleece filter bag

      1. Unlock and remove the suction head.

      2. Fit the fleece filter bag.


      3. Fit and lock the suction head.

      Wet vacuum cleaning

      DANGER

      Danger from dust that is harmful to your health

      Respiratory sicknesses through inhalation of dust.

      No dusts harmful to health may be vacuumed when performing wet vacuum cleaning.

      Note

      The candle filter available as an accessory with the order number 2.414-000.0 is not suitable for wet vacuum cleaning.

      Installing the squeegees

      1. Remove the brush strip.


      2. Install the squeegees.

      Closing the suction connection

      1. Fit a plug exactly into the suction connection.


      2. Push the plugs in until they engage.

      3. Close the suction connection tightly with the plug by turning it clockwise.

        Note

        The bayonet connection ensures a precise fit.

      Removing the fleece filter bag

      • The fleece filter bag must always be removed when vacuuming wet substances.

      1. Unlock and remove the suction head.

      2. Pull the fleece filter bag out to the rear.


      3. Fold in the cap and seal the fleece filter bag tight.

      4. Dispose of the used fleece filter bag in accordance with statutory regulations.

      5. Fit and lock the suction head.

      General

      ATTENTION

      Danger due to fine dust entering

      Risk of damage to the suction motor.

      Never remove the flat fold filter when vacuuming.

      • The device switches off automatically when the maximum fluid level is reached.

      • When vacuuming non-conductive liquids (e.g. drill emulsion, oils and grease) the device does not automatically switch off when the container is full. The filling level must be continuously monitored and the container emptied on a timely basis.

      • On completion of wet vacuum cleaning: dry the flat fold filter Clean the electrodes with a brush. Clean the container with a moist cloth and dry it off.

      Operation

      Each time before use

      1. Check the mains cable for damage, have a damaged cable replaced immediately by the authorised Customer Service or a qualified electrician.

      2. Check flat fold filter or candle filter (special accessory) for damage, replace damaged filter immediately.

      Rotary switch

      Device OFF
      Device ON

      Switching on the device

      1. Connect the mains plug.

      2. Switch on the device at the turn switch.

      Cleaning mode

      1. Perform cleaning.

      Switching off the device

      1. Switch off the device at the turn switch.

      2. Pull out the mains plug.

      Each time after use

      1. Empty the container.

      2. Vacuum off the inside and outside of the device and clean with a moist cloth.

      3. A vacuum cleaner with at least the same or better classification must be used for vacuuming the device.

      4. Remove the accessories and, if necessary, flush with water and allow to dry.

      Folding the push handle in/out

      1. Release the push handle fastening screws and adjust the push handle.

      Storing the device

      1. Store the suction hose and mains cable as shown in the illustration.


      2. Store the device in a dry room and secure it against unauthorised use.

      Transport

      CAUTION

      Failure to observe the weight

      Risk of injury and damage

      Be aware of the weight of the device during transportation.

      When transporting the device, ensure that it is securely fastened.

      The following measures must be taken for the dust-free transport of the device:

      1. Clean the suction hose and accessories with a damp cloth.

      2. Close the suction connection, see wet vacuum cleaning.

      3. Remove the suction hose with floor nozzle from the support. Carry the device by the carrying handle and suction pipe.

      4. When transporting the device in vehicles, secure it to prevent it from slipping or overturning in accordance with the respective valid guidelines.

      Storage

      CAUTION

      Failure to observe the weight

      Risk of injury and damage

      Be aware of the weight of the device during storage.

      The device may only be operated indoors.

      Care and service

      DANGER

      Danger of electric shock

      Injuries due to touching live parts

      Switch off the device.

      Remove the mains plug.

      Dust extraction machines are safety devices for the prevention or elimination of hazards according to the German DGUV regulation 1 (German accident prevention regulation, principles of prevention).

      ATTENTION

      Care agents containing silicone

      These can attach plastic components.

      Do not use care agents containing silicone for cleaning.

      • You can perform basic maintenance and care work yourself.

      • Clean the surface of the device and the interior of the container regularly with a moist cloth.

      Replacing the flat fold filter

      1. Open the filter cover.

      2. Remove the filter frame.


      3. Remove the flat fold filter.

      4. Dispose of the used flat fold filter in accordance with statutory regulations.

      5. Remove any dirt deposits from the clean air side.

      6. Clean the filter frame and the supporting surface of the filter frame with a damp cloth.

      7. Fit the new flat fold filter. During insertion, ensure that the flat fold filter is flush on all sides.

      8. Insert the filter frame.

      9. Close the filter cover until it audibly latches into place.

      Change the candle filter

      1. Open the filter cover.

      2. Take out the candle filter (special accessories).


      3. Dispose of the used candle filter (special accessories) in accordance with statutory regulations.

      4. Remove any dirt deposits from the clean air side.

      5. Clean the candle filter frame with a damp cloth.

      6. Insert the new candle filter (special accessories).

      7. Close the filter cover until it audibly latches into place.

      Changing the fleece filter bag

      1. Close the suction connection, see wet vacuum cleaning.


      2. Unlock and remove the suction head.

      3. Pull the fleece filter bag out to the rear.


      4. Fold in the cap and seal the fleece filter bag tight.

      5. Dispose of the used fleece filter bag in accordance with statutory regulations.

      6. Fit the new fleece filter bag.

      7. Fit and lock the suction head.

      Cleaning the cooling air filter

      1. Vacuum the cooling air filter from the outside (when installed) at regular intervals.

      Changing the cooling air filter

      Note

      The cooling air filter may only be changed in conjunction with the filter casing to ensure proper functioning of the suction unit.

      Order number of cooling air filter set (2x filter casing, 2x cooling air filter): 4.101-163.0

      1. Allow the device to cool down.

      2. Insert 2 flat-blade screwdrivers into the filter casing openings on the suction head as far as they will go.


      3. Press both flat-blade screwdrivers down and carefully lever out the filter casing.

      4. Remove the filter casing (with cooling air filter).

      5. Insert a new cooling air filter in the new filter casing according to the illustration.

      6. Insert the new filter casing (with cooling air filter) into the suction head and snap it into place.

      Cleaning the electrodes

      1. Unlock and remove the suction head.

      2. Clean the electrodes with a brush.

      3. Fit and lock the suction head.

      Troubleshooting guide

      DANGER

      Danger of electric shock

      Injuries due to touching live parts

      Switch off the device.

      Remove the mains plug.

      Note

      The device must be switched off immediately if a malfunction occurs (e.g. filter breakage). The malfunction must be eliminated before switching the device on again.

      • Suction turbine does not start up 

      • Suction turbine switches off 

      • Suction turbine does not switch on again after emptying the container 

      • Suction force decreases 

      • Escaping dust when vacuuming 

      • The automatic switch-off mechanism (wet vacuum cleaning) does not trigger 

      • "Vacuum pressure" indicator light flashes red 

      Suction turbine does not start up

      Remedy:

      1. Check the socket and the power supply fuse.

      2. Check the mains cable, mains plug and electrodes on the device.

      3. Switch on the device.

      Suction turbine switches off

      Remedy:

      1. Empty the container.

      2. Insert the flat fold filter or candle filter (special accessories).

      3. Change the flat fold filter or candle filter (special accessories).

      Cause:

      The thermal protection has switched off the motor due to overheating

      Remedy:

      1. Allow the device to cool down. Clean or replace the cooling air filter.

      Suction turbine does not switch on again after emptying the container

      Remedy:

      1. Switch off the device and wait for 5 seconds. Switch on the device.

      2. Clean the electrodes with a brush.

      Suction force decreases

      Remedy:

      1. Remove any blockages from the suction nozzle, suction pipe, suction hose, flat fold filter or candle filter (special accessory).

      2. Change the filled fleece filter bag.

      3. Correctly engage the filter cover.

      4. Replace the flat fold filter.

      5. Change the candle filter (special accessories).

      Escaping dust when vacuuming

      Remedy:

      1. Only with flat fold filters: Check that the flat fold filter is correctly fitted and correct if necessary.

      2. Replace the flat fold filter.

      3. Change the candle filter (special accessories).

      The automatic switch-off mechanism (wet vacuum cleaning) does not trigger

      Remedy:

      1. Clean the electrodes with a brush.

      2. Continuously monitor the filling level when vacuuming non-conductive liquids.

      "Vacuum pressure" indicator light flashes red

      Remedy:

      1. The fleece filter bag must be replaced when it is full and the air flow drops below the specified minimum flow rate.

      2. Replace the flat fold filter.

      3. Change the candle filter (special accessories).

      4. Remove any blockages from the suction nozzle, suction pipe or suction hose.

      Customer Service department

      If the malfunction cannot be corrected, the device must be checked by the Customer Service department.

      • Suction turbine does not start up 

      • Suction turbine switches off 

      • Suction turbine does not switch on again after emptying the container 

      • Suction force decreases 

      • Escaping dust when vacuuming 

      • The automatic switch-off mechanism (wet vacuum cleaning) does not trigger 

      • "Vacuum pressure" indicator light flashes red 

      Suction turbine does not start up

      Remedy:

      1. Check the socket and the power supply fuse.

      2. Check the mains cable, mains plug and electrodes on the device.

      3. Switch on the device.

      Suction turbine switches off

      Remedy:

      1. Empty the container.

      2. Insert the flat fold filter or candle filter (special accessories).

      3. Change the flat fold filter or candle filter (special accessories).

      Cause:

      The thermal protection has switched off the motor due to overheating

      Remedy:

      1. Allow the device to cool down. Clean or replace the cooling air filter.

      Suction turbine does not switch on again after emptying the container

      Remedy:

      1. Switch off the device and wait for 5 seconds. Switch on the device.

      2. Clean the electrodes with a brush.

      Suction force decreases

      Remedy:

      1. Remove any blockages from the suction nozzle, suction pipe, suction hose, flat fold filter or candle filter (special accessory).

      2. Change the filled fleece filter bag.

      3. Correctly engage the filter cover.

      4. Replace the flat fold filter.

      5. Change the candle filter (special accessories).

      Escaping dust when vacuuming

      Remedy:

      1. Only with flat fold filters: Check that the flat fold filter is correctly fitted and correct if necessary.

      2. Replace the flat fold filter.

      3. Change the candle filter (special accessories).

      The automatic switch-off mechanism (wet vacuum cleaning) does not trigger

      Remedy:

      1. Clean the electrodes with a brush.

      2. Continuously monitor the filling level when vacuuming non-conductive liquids.

      "Vacuum pressure" indicator light flashes red

      Remedy:

      1. The fleece filter bag must be replaced when it is full and the air flow drops below the specified minimum flow rate.

      2. Replace the flat fold filter.

      3. Change the candle filter (special accessories).

      4. Remove any blockages from the suction nozzle, suction pipe or suction hose.

      Disposal

      At the end of its service life, the device is to be disposed of in accordance with statutory regulations.

      Warranty

      The warranty conditions issued by our relevant sales company apply in all countries. We shall remedy possible malfunctions on your appliance within the warranty period free of cost, provided that a material or manufacturing flaw is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.

      Further information can be found at: www.kaercher.com/dealersearch

      Further warranty information (if available) can be found in the service area of your local Kärcher website under "Downloads".

      Accessories and spare parts

      DANGER

      Risk when used with non-permitted accessories

      Risk of explosion

      Only use accessories approved by the manufacturer for use with type 22. The use of other accessories may cause a risk of explosion.

      Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.

      Information on accessories and spare parts can be found at www.kaercher.com.

      Declaration of Conformity

      EU Declaration of Conformity

      We hereby declare that the machine described below complies with the relevant basic safety and health requirements in the EU Directives, both in its basic design and construction as well as in the version placed in circulation by us. This declaration is invalidated by any changes made to the machine that are not approved by us.

      Product: Wet/dry vacuum cleaner

      Type: 1.667-xxx

      Currently applicable EU Directives

      2006/42/EC (+2009/127/EC)

      2011/65/EU

      2014/30/EU

      2014/34/EU

      Harmonised standards used

      EN IEC 63000: 2018

      EN 55014-1: 2017 + A11: 2020

      EN 55014-2: 1997 + A1: 2001 + A2: 2008

      EN 60079-0: 2012 / A11: 2013

      EN 60079-11: 2012

      EN 60079-31: 2014

      EN 60335-1

      EN 60335-2-69

      EN 61000-3-2: 2014

      EN 61000-3-3: 2013

      EN 62233: 2008

      EN ISO 80079-36: 2016

      EN ISO 80079-37: 2016

      National standards used

      -

      Designation
      II 3 D Ex h IIIC T105 °C Dc X

      The signatories act on behalf of and with the authority of the company management.


      Documentation supervisor:

      S. Reiser

      Alfred Kärcher SE & Co. KG

      Alfred-Kärcher-Str. 28 - 40

      71364 Winnenden (Germany)

      Ph.: +49 7195 14-0

      Fax: +49 7195 14-2212

      Winnenden, 2022/10/01

      Declaration of Conformity (UK)

      We hereby declare that the product described below complies with the relevant provisions of the following UK Regulations, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the product is modified without our prior approval.

      Product: Wet/dry vacuum cleaner

      Type: 1.667-xxx

      Currently applicable UK Regulations

      S.I. 2008/1597 (as amended)

      S.I. 2012/3032 (as amended)

      S.I. 2016/1091 (as amended)

      S.I. 2016/1107 (as amended)

      Designated standards used

      EN IEC 63000: 2018

      EN 55014-1: 2017 + A11: 2020

      EN 55014-2: 1997 + A1: 2001 + A2: 2008

      EN 60079-0: 2012 / A11: 2013

      EN 60079-11: 2012

      EN 60079-31: 2014

      EN 60335-1

      EN 60335-2-69

      EN 61000-3-2: 2014

      EN 61000-3-3: 2013

      EN 62233: 2008

      EN ISO 80079-36: 2016

      EN ISO 80079-37: 2016

      National standards used

      -

      Designation
      II 3 D Ex h IIIC T105 °C Dc X

      The signatories act on behalf of and with the authority of the company management.


      Documentation supervisor:

      S. Reiser

      Alfred Kärcher SE & Co. KG

      Alfred-Kärcher-Str. 28 - 40

      71364 Winnenden (Germany)

      Ph.: +49 7195 14-0

      Fax: +49 7195 14-2212

      Winnenden, 2022/10/01

      Technical data

        

      Electrical connection
      Mains voltage
      220-240 V
      Phase
      1 ~
      Power frequency
      50-60 Hz
      Degree of protection
      IP64
      Protection class
      I
      Nominal power
      1200 W
      Maximum power
      1380 W
      Device performance data
      Tank content
      75 l
      Fluid filling quantity
      58 l
      Air quantity (max.)
      145 (40) m3/h (l/s)
      Vacuum (max.)
      22,0 (220) kPa (mbar)
      Air quantity (max., suction motor)
      234 (65) m3/h (l/s)
      Vacuum (max., suction motor)
      25,0 (250) kPa (mbar)
      Ignition protection class (EN 60079-11, in dust collection container)
      ia
      Ignition protection class (EN 60079-31, in the environment)
      tc
      Ignition protection class (EN ISO 80079-37, in the environment)
      h
      Dimensions and weights
      Typical operating weight
      24,1 kg
      Length x width x height
      695 x 540 x 1012 mm
      Filter area of the flat fold filter
      0,6 m2
      Candle filter area
      0,2 m2
      Diameter of the suction hose
      40 mm
      Length of the suction hose
      4,0 m
      Ambient conditions
      Ambient temperature
      0...+40 °C
      Relative humidity
      30-90 %
      Determined values in acc. with EN 60335-2-69
      Sound pressure level LpA
      67 dB(A)
      Uncertainty KpA
      1 dB(A)
      Hand-arm vibration value
      <2,5 m/s2
      Uncertainty K
      0,2 m/s2
      Mains cable
      Power cord type
      H07RN-F 3x1,5 mm2
      Part number (EU)
      6.652-126.0
      Cable length
      10 m
      <BackPage>

      Filtersysteme / Filter Systems / Système de filtres

       
       
       
      Flachfaltenfilter PES *
      Flat pleated filter PES *
      Filtre plat à plis PES *
      Kerzenfilter *
      Candle filter *
      Filtre à bougie *
      Vliesfiltertüte, 2-lagig *
      Fleece filter bag, double layered *
      Sachet filtre en tissu non tissé à 2 épaisseurs *
      Bestellnummer
      Order No.
      Numéro de référence
      6.907-662.0
      2.414-000.0
      2.885-753.0
      Menge
      Quantity
      Quantité
      1
      1
      5
      Normalstäube
      Normal dust
      Poussières normales
      x
      x
      x
      Feinstäube
      Fine dust
      Poussières fines
      x
      x
      x
      Abrasive Stäube
      Abrasive dust
      Poussières abrasives
      x
      x
      x
      Flüssigkeiten, nasser Schmutz
      Liquids, wet dirt
      Liquides, saletès humides
      x

      * Staubklasse M, Rückhaltevermögen ≥ 99,9 %

      * Dust class M, Retention ≥ 99,9 %

      * Classe de poussière M, Conservation ≥ 99,9 %

      Standardzubehör / Standard accessories / Accessoires standards

       
       
       
       
       
      2.889-364.0
      DN 40 EL
      4,0
       
      2.889-368.0
      DN 40
      0,3
       
      2.889-366.0
      DN 40 EL
       
      2.889-369.0
      DN 40
      360
       
      2.889-411.0
      DN 35
       
      2.889-367.0
      (2x)
      DN 40
      0,55

      EL = elektrisch leitend, electrical conductive, conducteur électrique

      DN = Konus-Verbindung, cone connection, connexion de cône

      Sonderzubehör / Special accessories / Accessoires spéciaux

       
       
       
       
       
      2.889-365.0
      DN 40 EL
      8,0
       
      2.889-390.0
      DN 40
      450
       
      2.889-410.0
      DN 40 / DN 35

      EL = elektrisch leitend, electrical conductive, conducteur électrique

      DN = Konus-Verbindung, cone connection, connexion de cône


       

        

       



      </BackPage>