T 10/1T 10/1 Adv/HEPAT 15/1T 15/1 Adv/HEPA

59793850 (09/24)
59793850 (09/24)
Read these original instructions and the enclosed safety instructions before using the device for the first time. Act in accordance with them.
Keep both books for future reference or for future owners.
If the operating instructions and safety instructions are not observed, the device can be damaged and dangers could arise for users and other persons.
Notify the dealer immediately in the case of shipping damage.
Check the package contents when unpacking for missing accessories or for damage.
The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.
Electrical and electronic devices contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which - if handled or disposed of incorrectly - can pose a potential danger to human health and the environment. However, these components are required for the correct operation of the device. Devices marked by this symbol are not allowed to be disposed of together with the household rubbish.
Current information on content materials can be found at: www.kaercher.de/REACH
Health risk
Inhalation of dusts that are harmful to health
Do not use the device for vacuuming up dusts that are harmful to health.Damage to the device
Short-circuit due to high levels of humidity
Only use and store the device indoors.This universal vacuum cleaner for carpets is intended for dry cleaning floor and wall surfaces.
This device is suitable for commercial use, e.g. in hotels, schools, hospitals, factories, shops, offices, and rental companies.
The control elements for the cleaning process are yellow.
The control elements for maintenance and servicing are light grey.
Unpack the device and install the accessories.
Check whether the permanent filter basket is attached to the suction head.
Operation with the filter bag
Operation without the filter bag
Unlock and remove the exhaust grille.
Remove the exhaust gas filter casing.
Insert the HEPA filter (special accessory).
Attach and lock the exhaust grille.
Unlock and remove the suction head.
Fit the fleece filter bag. Pull the opening of the filter bag completely over the shoulder of the suction hose port.
Fit the suction head and lock.
Connect the mains plug.
Switch on the device at the main switch.
Regulate the suction power on the suction control.
Set the floor nozzle switch to hard surface or carpet.
Perform cleaning.
Switch off the device at the main switch.
Pull out the mains plug.
Empty the container.
Vacuum the inside and outside of the device and clean with a moist cloth.
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during transportation.When transporting the device in vehicles, secure it to prevent it from slipping or overturning in accordance with the respectively applicable guidelines.
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during storage.The device may only be operated indoors.
Danger of electric shock
Injuries due to touching live parts
Switch off the device.Remove the mains plug.Danger due to wet permanent filter basket
Risk of damage to the device
Never insert the permanent filter basket when wet.Unlock and remove the suction head.
Turn the suction head by 180° and set it down.
Unlock and remove the permanent filter basket.
If necessary, clean the permanent filter basket (washable) under running water and let it dry.
Fit the permanent filter basket and snap it into place.
Fit the suction head and lock.
Unlock and remove the suction head.
Remove the fleece filter bag from the suction hose port.
Fold in the lock latch and seal the fleece filter bag tight.
Fit a new fleece filter bag. Pull the opening of the filter bag completely over the shoulder of the suction hose port.
Fit the suction head and lock.
Exhaust filter: replace as required, but at least once a year
Unlock and remove the exhaust grille.
Remove the exhaust gas filter casing.
Remove the exhaust filter from the exhaust gas filter casing.
Insert a new exhaust filter in the exhaust filter casing.
Insert the exhaust gas filter casing.
Attach and lock the exhaust grille.
HEPA filter: replace as required, but at least once a year
Unlock and remove the exhaust grille.
Remove the HEPA filter (special accessories).
Insert a new HEPA filter (special accessory).
Attach and lock the exhaust grille.
Unlock and remove the suction head.
Turn the suction head by 180° and set it down.
Unlock and remove the permanent filter basket.
Remove the motor protection filter.
Fit a new motor protection filter.
Fit the permanent filter basket and snap it into place.
Fit the suction head and lock.
Unscrew and remove the mains cable guide.
Unscrew and remove the cover of the cable drum.
Unwind the mains cable from the cable drum.
Unplug and remove the mains cable.
Plug in the new mains cable and route it as shown in the illustration (strain relief).
Turn the cable drum 90° anti-clockwise so that the mains cable is slightly pre-tensioned and thus lies tightly against the pin.
Position the cover of the cable drum so that the mains cable is not crushed. Fasten the cover.
Wind up the mains cable in a clockwise direction.
Attach and fasten the mains cable guide.
Danger of electric shock
Injuries due to touching live parts
Switch off the device.Remove the mains plug.The device stops during operation
Cause:
The motor thermo-protector has triggered
Remedy:
Check all parts for clogging.
Change the fleece filter bag.
Replace the motor protection filter.
Replace the exhaust filter or the HEPA filter (optional accessory).
Allow the engine turbine to cool for approx. 30-40 minutes. Switch the device on again.
Suction turbine does not start up
Remedy:
Check the socket and the power supply fuse.
Check the mains cable and the mains plug of the device.
Turn on the device again.
Suction force decreases
Remedy:
Remove all blockages from the suction nozzle, the suction pipe or the suction hose.
Change the fleece filter bag.
Clean the permanent filter basket under running water and allow to dry.
Position/lock the suction head correctly.
Replace a defective suction hose.
Replace the motor protection filter.
Escaping dust when vacuuming
Remedy:
Check the fit of the fleece filter bag.
Change the fleece filter bag.
Position/lock the suction head correctly.
Clean the permanent filter basket under running water and allow to dry.
Insert a new permanent filter basket.
Correctly insert the motor protection filter or replace.
If the malfunction cannot be corrected, the device must be checked by the Customer Service department.
The device stops during operation
Cause:
The motor thermo-protector has triggered
Remedy:
Check all parts for clogging.
Change the fleece filter bag.
Replace the motor protection filter.
Replace the exhaust filter or the HEPA filter (optional accessory).
Allow the engine turbine to cool for approx. 30-40 minutes. Switch the device on again.
Suction turbine does not start up
Remedy:
Check the socket and the power supply fuse.
Check the mains cable and the mains plug of the device.
Turn on the device again.
Suction force decreases
Remedy:
Remove all blockages from the suction nozzle, the suction pipe or the suction hose.
Change the fleece filter bag.
Clean the permanent filter basket under running water and allow to dry.
Position/lock the suction head correctly.
Replace a defective suction hose.
Replace the motor protection filter.
Escaping dust when vacuuming
Remedy:
Check the fit of the fleece filter bag.
Change the fleece filter bag.
Position/lock the suction head correctly.
Clean the permanent filter basket under running water and allow to dry.
Insert a new permanent filter basket.
Correctly insert the motor protection filter or replace.
The warranty conditions issued by our relevant sales company apply in all countries. We shall remedy possible malfunctions on your appliance within the warranty period free of cost, provided that a material or manufacturing flaw is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.
Further information can be found at: www.kaercher.com/dealersearch
Further warranty information (if available) can be found in the service area of your local Kärcher website under "Downloads".
Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.
Information on accessories and spare parts can be found at www.kaercher.com.
EU Declaration of Conformity |
We hereby declare that the machine described below complies with the relevant basic safety and health requirements in the EU Directives, both in its basic design and construction as well as in the version placed in circulation by us. This declaration is invalidated by any changes made to the machine that are not approved by us.
Product: Dry vacuum cleaner
Type: 1.355-xxx
Type: 1.527-xxx
Currently applicable EU Directives2006/42/EC (+2009/127/EC)
2009/125/EC
2011/65/EU
2014/30/EU
Harmonised standards usedEN IEC 63000: 2018
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 2015
EN 60312-1: 2017
EN 60335-1
EN 60335-2-69
EN 61000-3-2: 2014
EN 61000-3-3: 2013
EN 62233: 2008
National standards used-
Commission Regulation(s)666/2013
The signatories act on behalf of and with the authority of the company management.
Documentation supervisor:
S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2020/10/01
Declaration of Conformity (UK) |
We hereby declare that the product described below complies with the relevant provisions of the following UK Regulations, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the product is modified without our prior approval.
Product: Dry vacuum cleaner
Type: 1.355-xxx
Type: 1.527-xxx
Currently applicable UK RegulationsS.I. 2008/1597 (as amended)
S.I. 2010/2617 (as amended)
S.I. 2012/3032 (as amended)
S.I. 2016/1091 (as amended)
Designated standards usedEN IEC 63000: 2018
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 2015
EN 60312-1: 2017
EN 60335-1
EN 60335-2-69
EN 61000-3-2: 2014
EN 61000-3-3: 2013
EN 62233: 2008
National standards used-
Commission Regulation(s)(EU) No 666/2013
The signatories act on behalf of and with the authority of the company management.
Documentation supervisor:
S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2020/10/01
Electrical connection | |
Mains voltage | 220-240 V |
Phase | 1 ~ |
Power frequency | 50-60 Hz |
Protection class | II ![]() |
Rated power input | 500 W |
Device performance data | |
Tank content | 10 l |
Air quantity (max.) | 38 l/s |
Vacuum (max.) | 18,5 (185) kPa (mbar) |
Dimensions and weights | |
Length x width x height | 430 x 255 x 370 mm |
Typical operating weight | 6,6 kg |
Diameter of the suction hose | 35 mm |
Ambient conditions | |
Ambient temperature (max.) | +40 °C |
Determined values in acc. with EN 60335-2-69 | |
Sound pressure level LpA | 52 dB(A) |
Uncertainty KpA | 2 dB(A) |
Sound power level LwA | 64 dB(A) |
Hand-arm vibration value | <2,5 m/s2 |
Uncertainty K | 0,2 m/s2 |
Mains cable | |
Power cord type | H05VV 2x1,0 GF mm2 |
Part number (EU) | 6.650-915.0 |
Part number (GB) | 6.652-282.0 |
Part number (CH) | 6.652-281.0 |
Cable length | 12 m |
Electrical connection | |
Mains voltage | 220-240 V |
Phase | 1 ~ |
Power frequency | 50-60 Hz |
Protection class | II ![]() |
Rated power input | 500 W |
Device performance data | |
Tank content | 15 l |
Air quantity (max.) | 38 l/s |
Vacuum (max.) | 18,5 (185) kPa (mbar) |
Dimensions and weights | |
Length x width x height | 430 x 255 x 420 mm |
Typical operating weight | 6,9 kg |
Diameter of the suction hose | 35 mm |
Ambient conditions | |
Ambient temperature (max.) | +40 °C |
Determined values in acc. with EN 60335-2-69 | |
Sound pressure level LpA | 52 dB(A) |
Uncertainty KpA | 2 dB(A) |
Sound power level LwA | 64 dB(A) |
Hand-arm vibration value | <2,5 m/s2 |
Uncertainty K | 0,2 m/s2 |
Mains cable | |
Power cord type | H05VV 2x1,0 GF mm2 |
Part number (EU) | 6.650-915.0 |
Part number (GB) | 6.652-282.0 |
Part number (CH) | 6.652-281.0 |
Cable length | 12 m |