LogoNT 30/1 Tact Te H ACDNT 40/1 Tact Te H ACDNT 50/1 Tact Te H ACD
  • General notes
  • Environmental protection
  • Intended use
  • Description of the device
  • Symbols on the device
    • Asbestos marking
    • Dust class
    • ACD dust remover
  • Safety devices
    • Monitoring of the flat fold filter
  • Safety instructions
  • Preparation
  • Initial startup
    • Horn
      • Intermittent tone
      • Continuous tone
    • Anti-static system
    • Dry vacuuming
      • Installing the safety filter bag
      • Installing the dust bag
    • Wet vacuum cleaning
      • Installing the squeegees
      • Closing the suction connection
      • Removing the safety filter bag
      • Removing the dust bag
      • Draining the waste water
      • General
    • Clip connection
  • Operation
    • Each time before use
    • Turn switch
    • Switching on the device
    • Working with power tools
    • Automatic filter dedusting
    • Switching off the device
    • Each time after use
    • Folding the push handle in/out
    • Storing the device
  • Transport
  • Storage
  • Care and maintenance
    • Replacing the flat fold filter
    • Changing the safety filter bag
    • Changing the dust bag
    • Cleaning/replacing the cooling air filter
    • Cleaning the electrodes
  • Troubleshooting guide
    • Suction turbine does not start up

    • Suction turbine switches off

    • Suction turbine does not switch on again after emptying the container

    • Suction power decreases

    • Escaping dust when vacuuming

    • The automatic switch-off mechanism (wet vacuum cleaning) does not trigger

    • Horn sounds - intermittent tone

    • Horn sounds - continuous tone

    • Automatic filter dedusting not working

    • The automatic filter dedusting function cannot be switched off

    • The automatic filter dedusting function cannot be switched on

  • Customer Service department
    • Suction turbine does not start up

    • Suction turbine switches off

    • Suction turbine does not switch on again after emptying the container

    • Suction power decreases

    • Escaping dust when vacuuming

    • The automatic switch-off mechanism (wet vacuum cleaning) does not trigger

    • Horn sounds - intermittent tone

    • Horn sounds - continuous tone

    • Automatic filter dedusting not working

    • The automatic filter dedusting function cannot be switched off

    • The automatic filter dedusting function cannot be switched on

  • Disposal
  • Warranty
  • Accessories and spare parts
  • EU Declaration of Conformity
  • Technical data
    • NT 30/1 Tact Te H ACD
    • NT 40/1 Tact Te H ACD
    • NT 50/1 Tact Te H ACD

      NT 30/1 Tact Te H ACD
      NT 40/1 Tact Te H ACD
      NT 50/1 Tact Te H ACD

      59991600 (10/24)

      General notes

      these original instructions and the enclosed safety notes no. 59562490 before using the device for the first time. Proceed accordingly.

      Keep both books for future reference or for future owners.

      • If the operating instructions and safety instructions are not observed, the device can be damaged and dangers could arise for users and other persons.

      • Notify the dealer immediately in the case of shipping damage.

      • When unpacking, check the package contents for missing accessories or signs of damage.

      Environmental protection

      The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.

      Electrical and electronic devices contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which - if handled or disposed of incorrectly - can pose a potential danger to human health and the environment. However, these components are required for the correct operation of the device. Devices marked by this symbol are not allowed to be disposed of together with the household rubbish.

      Notes on the content materials (REACH)

      Current information on content materials can be found at: www.kaercher.de/REACH

      Intended use

      • This wet/dry vacuum cleaner is designed to remove dry dirt and liquids.

      • This device is suitable for vacuuming dry, flammable dusts that are harmful to health; dust class H as per EN/IEC 60335-2-69

      • Industrial vacuums and portable dust removal devices in accordance with Technical Rule 519 (TRGS 519) Appendix 7.1 may be used for the following applications:

        1. Activities in enclosed spaces with low exposure in accordance with TRGS 519 number 2.8 or small-scale work in accordance with TRGS 519 number 2.10.

        2. Cleaning work. In the Federal Republic of Germany, the regulations in TRGS 519 (Technical Rules for Hazardous Substances) apply to asbestos vacuum cleaners.

      • After using the asbestos vacuum cleaner in the sealed-off area as per TRGS 519, the asbestos vacuum cleaner may no longer be used in the “white area”. Exceptions are only permitted if the asbestos vacuum cleaner has been fully decontaminated by a certified expert according to TRGS 519 No. 2.7 (i.e., not just the outer casing, but also e.g. the cooling chamber, installation spaces for electrical equipment, the equipment itself, etc.). This is to be recorded in writing and signed by the technical expert.

      • The flat fold filter (GF) 6.904-242.0 (material marking B) may only be used in combination with the safety filter bag 2.889-183.0 or 2.889-184.0.

      • There is a risk of fire and explosion when vacuuming combustible dusts. Use only by qualified users.

      • WARNING - This device may only be used to collect the combustible dusts specified by the manufacturer. Combinations of different metals or dusts can lead to fires or explosions (exothermic reactions).

      • This device is suitable for vacuuming combustible dusts, with the exception of aluminium dust or powder and magnesium dust or powder, in non-classified (normal) areas.

      • It is not permitted to pick up hot particles or glowing substances, as they can cause a fire and explosion in the hose or container.

      • This device is not suitable for vacuuming liquids with a flash point below 55 °C.

      • This device is not suitable for vacuuming dusts with an ignition energy of less than 1 mJ.

      • The device is suitable for the direct extraction of dust-generating power tools (use as a dust remover), but not for devices that generate ignition sources.

      • It must be ensured that no ignition sources are picked up.

      • This device is not suitable for use in classified, hazardous areas ATEX zones), for vacuuming dusts or liquids with a high risk of explosion or mixtures of combustible dust and liquids.

      • This device is suitable for commercial use,e.g. in hotels, schools, hospitals, factories, shops, offices, and rental companies.

      • For Switzerland only: The socket outlet shall only be used during operation in dry condition.

      Description of the device


      1. Electrodes
      2. Suction hose port
      3. Suction hose
      4. Hose hook
      5. Push handle lock (NT 50/1 only)
      6. Crevice nozzle
      7. Air exit, working air
      8. Suction head
      9. Suction head lock
      10. Recessed grip
      11. Dirt receptacle
      12. Steering roller
      13. Handle
      14. Air inlet, motor cooling air
      15. Plug
      16. Floor nozzle
      17. Suction pipe
      18. Tool box end stop
      19. Rubber sleeve, screwable
      20. Fastening eyelet
      21. Filter cover
      22. Carrying handle
      23. Suction control (variable)
      24. Tool adapter
      25. Push handle (NT 50/1 only)
      26. Hose cross section turn switch
      27. Hose cross-section scale
      28. Turn switch with suction output regulation
      29. Socket
      30. Floor nozzle holder
      31. Drain hose (NT 50/1 only)
      32. Suction pipe holder
      33. Cable hook (NT 50/1 only)
      34. Lock latch of the filter cover
      35. Angle piece
      36. Mains cable
      37. Angle piece holder (NT 30/1, NT 40/1 only)
      38. Filter frame
      39. Flat fold filter (PTFE H)
      40. Filter dedusting
      41. Type plate

      Symbols on the device

      Asbestos marking

       
      CAUTION CONTAINS ASBESTOS. Health risk posed by inhalation of fine asbestos dust. Observe safety regulations.

      Dust class

      WARNING: This machine contains dust that is harmful to your health. Emptying and maintenance, including removal of the dust bag, may only be performed by technical specialists wearing suitable personal protective equipment. Do not operate the device without the complete filtration system.

      ACD dust remover

      The device is suitable for vacuuming flammable dusts.

      Safety devices

      Monitoring of the flat fold filter

      The device automatically switches off when operated without a flat fold filter.

      Safety instructions

      DANGER

      Risk of injury, explosion and damage

      Observe the following safety instructions when handling the device.
      • The included accessories are electrically conductive. The device may only be used with electrically conductive accessories that have been approved by KÄRCHER. There is a risk of explosion if other accessories are used.

      • The user must be aware of all relevant properties of the combustible dusts that the device sucks up and determine the associated safety aspects.

      Preparation

      1. Unpack the device and install the accessories.


      Initial startup

      The device has 2 operating modes:

      1. Industrial vacuum cleaner operation (power socket not used)

      2. Dust removal operation (power socket used)

      WARNING

      Danger from dust that is harmful to your health

      Respiratory sicknesses through inhalation of dust.

      Do not vacuum without correctly installed filter elements, otherwise a danger to health from increased fine dust emission is present.

      ATTENTION

      Danger due to fine dust entering

      Risk of damage to the suction motor.

      Never remove the flat fold filter when vacuuming.
      1. Connect the suction hose and attach a suction nozzle or connect to the dust generating device, depending on the operating mode.

      Horn

      Intermittent tone

      The horn sounds (intermittent tone) when the air speed drops below 20 m/s.

      Note

      The horn reacts to a vacuum.

      1. Set the turn switch to the correct hose cross-section.

      Continuous tone

      The horn sounds (continuous tone) when the cooling air filter is clogged.

      1. Allow the device to cool down. Clean/replace the cooling air filter.

      Anti-static system

      Static charges are discharged through the earthed connection nozzles. This prevents sparking and electric shocks with electrically conducting accessories (included in the scope of delivery).

      Dry vacuuming

      • NT 30/1: The device is equipped with a safety filter bag with sealing cap, order no. 2.889-183.0 (5 pieces).

      • NT 40/1, NT 50/1: The device is equipped with a safety filter bag with sealing cap, order no. 2.889-184.0 (5 pieces).

      • The device is equipped with a dust bag with cable ties, order no. 2.889-231.0 (10 pieces).

      Note

      All types of dust up to dust class H can be vacuumed with this device. The use of a dust collection bag (for order no. see filter systems) is required by law.

      Note

      The device is suitable for industrial extraction and a dust removal device for mobile operation for vacuuming dry, flammable dusts with workplace limit values (AGW).

      • Unused flat fold filters may only be stored and transported in their packaging (cardboard box).

      WARNING

      Danger from dust that is harmful to your health

      Respiratory sicknesses through inhalation of dust.

      Do not vacuum without a correctly installed safety filter bag/dust bag, otherwise a danger to health from increased fine dust emission is present.

      Installing the safety filter bag

      1. Unlock and remove the suction head.

      2. Pull the safety filter bag over the container.


      3. Attach the safety filter bag.


      4. Fit and lock the suction head.

      Installing the dust bag

      1. Unlock and remove the suction head.

      2. Insert the dust bag.


      3. Pull the dust bag over the container. Ensure that the marking line is within the container and the ventilation hole is positioned on the back wall of the container.

      4. Fit and lock the suction head.

      Wet vacuum cleaning

      DANGER

      Danger from dust that is harmful to your health

      Respiratory sicknesses through inhalation of dust.

      No dusts harmful to health may be vacuumed when performing wet vacuum cleaning.

      Installing the squeegees

      1. Remove the brush strip.


      2. Install the squeegees.

      Closing the suction connection

      1. Fit a plug exactly into the suction connection.


      2. Push the plugs in until they engage.

      Removing the safety filter bag

      • The safety filter bag must always be removed when vacuuming wet substances.

      1. Unlock and remove the suction head.

      2. Pull safety filter bag on the flange up and out.


      3. Seal the suction connection opening of the safety filter bag tightly with a sealing cap.

      4. Fold up the safety filter bag.


      5. Take off the protective film and close the ventilation hole (1x NT 30/1 - 2x NT 40/1, NT 50/1) with a self-adhesive tab.


      6. Close the safety filter bag tightly with the attached cable tie.

      7. Remove the safety filter bag.

      8. Clean the container inside with a moist cloth.

      9. Dispose of used safety filter bag in dust-tight bag in accordance with statutory regulations.

      10. Fit and lock the suction head.

      Removing the dust bag

      • The dust bag must always be removed when vacuuming wet substances.

      1. Unlock and remove the suction head.

      2. Fold up the dust bag.


      3. Take off the protective film and close the ventilation hole with a self-adhesive tab.

      4. Seal the dust bag tightly underneath the opening using cable ties.

      5. Remove the dust bag.

      6. Clean the container inside with a moist cloth.

      7. Dispose of the dust bag in accordance with statutory regulations.

      8. Fit and lock the suction head.

      Draining the waste water

      NT 50/1 only:

      1. Drain the waste water via the drain hose.


      General

      • We recommend switching off the "Automatic filter dedusting" function when vacuuming wet dirt with the crevice nozzle or the upholstery nozzle (optional), or when sucking mainly water out of a container.

      • The device switches off automatically when the maximum fluid level is reached.

      • When vacuuming non-conductive liquids (e.g. drill emulsion, oils and grease) the device does not automatically switch off when the container is full. The filling level must be continuously monitored and the container emptied on a timely basis.

      • On completion of wet vacuum cleaning: Clean the flat fold filter using the dedusting function and let it dry. Clean the electrodes with a brush. Clean the container with a moist cloth and dry it off.

      Clip connection

      The suction hose is equipped with a clip system. All accessory parts with a nominal width of 35 mm can be connected.


      Operation

      Note

      The suction hose must be handled carefully during operation to avoid kinks.

      Each time before use

      1. Check all filters for correct position and damage.

      Turn switch

      Device OFF
      • Device ON

      • Automatic filter dedusting: OFF

      • Adjust the suction performance (min-max)

      • Device ON

      • Automatic filter dedusting: ON

      • Adjust the suction performance (min-max) (eco = energy-saving mode)

      Switching on the device

      1. Connect the mains plug.

      2. Set the turn switch to the desired program.

      Working with power tools

      DANGER

      Danger of electric shock

      Risk of injury and damage.

      The socket is only intended for direct connection of power tools to the vacuum cleaner. Any other use of the socket is prohibited.
      1. Plug the mains plug of the power tool into the power socket on the vacuum cleaner. The vacuum cleaner is in Standby mode.

      2. Switch on the device at the turn switch.

        Note

        The vacuum cleaner is automatically switched on and off with the power tool.

        Note

        The vacuum cleaner has a startup delay of up to 0.5 seconds and an after-running time of up to 15 seconds.

        Note

        See the Technical data for the permissible power rating of the power tool.

      3. Remove the angle piece from the suction hose.


      4. Install the tool adapter on the suction hose.

      5. Connect the tool adapter to the power tool.


      6. Set the minimum volume flow on the turn switch for suction hose cross section. The scale shows the suction hose suction hose cross section.

        Note

        The different suction hose cross sections are necessary in order to adapt to the different connection cross sections of the processing machines.

        Note

        For operation as a dust removal device for mobile operation (processing machine plugged into the vacuum cleaner) the integrated monitoring system must be adjusted to suit the connected processing machine (dust generator). This means that the user must be warned when the flow rate drops below the minimum value 20 m/s needed for correct vacuuming.

        Note

        Information on the minimum flow rate depending on the vacuum can be found on the type plate.

      Automatic filter dedusting

      The device is equipped with a special filter dedusting function, which is particularly effective against fine dust. The flat fold filter is automatically cleaned every 7.5/15/60 seconds (depending on use) using an airflow (pulsing sound).

      1. Set the turn switch to program 2 (TACT AUTO).

      2. Power dedusting (for particularly severe contamination of the flat fold filter): Set the turn switch to program 2, seal the suction pipe or bender with your hand and wait for the automatic filter cleaning to finish (lasts 15 seconds).


      Switching off the device

      1. Switch off the device at the turn switch.

      2. Pull out the mains plug.

      Each time after use

      1. Empty the container.

      2. Vacuum off the inside and outside of the device and clean with a moist cloth.

      Folding the push handle in/out

      NT 50/1 only:

      1. Release the push handle lock and adjust the push handle.

      Storing the device

      1. Store the suction hose and mains cable as shown in the illustration.


      2. Store the device in a dry room and secure it against unauthorised use.

      Transport

      CAUTION

      Failure to observe the weight

      Risk of injury and damage

      Be aware of the weight of the device during transportation.

      When transporting the device, ensure that it is securely fastened.

      The following measures must be taken for the dust-free transport of the device:

      1. Place the suction hose with accessories in a suitable transport bag. Close the transport bag.

      2. Empty the container.

      3. Close the suction connection, see wet vacuum cleaning.

      4. Remove the suction hose with floor nozzle from the support. Carry the device by the carrying handle and the suction pipe, not by the push handle.

      5. When transporting the device in vehicles, secure it to prevent it from slipping or overturning in accordance with the respective valid guidelines.

      Storage

      CAUTION

      Failure to observe the weight

      Risk of injury and damage

      Be aware of the weight of the device during storage.

      The device may only be operated indoors.

      Care and maintenance

      DANGER

      Danger of electric shock

      Injuries due to touching live parts

      Switch off the device.Remove the mains plug.

      Dust extraction machines are safety devices for the prevention or elimination of hazards according to the German DGUV regulation 1 (German accident prevention regulation, principles of prevention).

      Note

      Industrial vacuums/dust removal devices must be serviced as required, but at least once a year, repaired if necessary and checked by an expert (qualified in accordance with TRGS 519 No. 5.3, Paragraph 2). The test result must be presented on request.

      ATTENTION

      Care agents containing silicone

      These can attach plastic components.

      Do not use care agents containing silicone for cleaning.
      • You can perform basic maintenance and care work yourself.

      • Clean the inside of the container and the suction hose regularly with a damp cloth and check for dust accumulation.

      • Clean the surface of the device regularly with a damp cloth, as a possible accumulation of dust on the device can be a potential source of ignition.

      • Perform regular ground continuity checks in accordance with federal, state, provincial and local laws and regulations.

      Replacing the flat fold filter

      DANGER

      Danger from dust that is harmful to your health

      Respiratory sicknesses through inhalation of dust.

      Accumulated dust must be transported in dust-proof containers. Do not transfer the contents. Waste that contains asbestos must be disposed of in accordance with the instructions and rules for waste disposal. The dust bag may only be disposed of by qualified staff.

      WARNING

      Danger from dust that is harmful to your health

      Respiratory sicknesses through inhalation of dust.

      Do not use the main filter element after removing it from the device.

      Permanently installed filters may only be replaced in suitable areas (e.g.decontamination stations) by a technical expert.

      Order number of flat fold filter: 6.907-671.0 or 6.904-242.0 (material marking B)

      1. Turn both fastening pins of the filter cover counter-clockwise with a screwdriver. Fastening pins are pushed out.


      2. Open the filter cover.

      3. Remove the filter frame.


      4. Remove the flat fold filter.

      5. When removing the flat fold filter, wrap it immediately with a suitable bag. Seal the bag.

      6. Dispose of used flat fold filter in dust-tight bag in accordance with statutory regulations.

      7. Remove any dirt deposits from the clean air side.

      8. Clean the filter frame and the supporting surface of the filter frame with a damp cloth.

      9. Fit the new flat fold filter. During insertion, ensure that the flat fold filter is flush on all sides.

      10. Insert the filter frame.

      11. Close the filter cover until it audibly latches into place.

      12. Press in both fastening pins of the filter cover with a screwdriver and tighten clockwise.

      Changing the safety filter bag

      DANGER

      Danger from dust that is harmful to your health

      Respiratory sicknesses through inhalation of dust.

      Accumulated dust must be transported in dust-proof containers. Do not transfer the contents. Waste that contains asbestos must be disposed of in accordance with the instructions and rules for waste disposal. The dust bag may only be disposed of by qualified staff.
      1. Close the suction connection, see wet vacuum cleaning.


      2. Unlock and remove the suction head.

      3. Pull safety filter bag on the flange up and out.


      4. Seal the suction connection opening of the safety filter bag tightly with a sealing cap.

      5. Fold up the safety filter bag.


      6. Take off the protective film and close the ventilation hole (1x NT 30/1 - 2x NT 40/1, NT 50/1) with a self-adhesive tab.


      7. Close the safety filter bag tightly with the attached cable tie.

      8. Remove the safety filter bag.

      9. Clean the container inside with a moist cloth.

      10. Dispose of used safety filter bag in dust-tight bag in accordance with statutory regulations.

      11. Pull the new safety filter bag over the container.


      12. Attach the safety filter bag.


      13. Fit and lock the suction head.

      Changing the dust bag

      1. Close the suction connection, see wet vacuum cleaning.


      2. Unlock and remove the suction head.

      3. Fold up the dust bag.


      4. Take off the protective film and close the ventilation hole with a self-adhesive tab.

      5. Seal the dust bag tightly underneath the opening using cable ties.

      6. Remove the dust bag.

      7. Clean the container inside with a moist cloth.

      8. Dispose of the dust bag in accordance with statutory regulations.

      9. Fit the new dust bag.


      10. Pull the dust bag over the container. Ensure that the marking line is within the container and the ventilation hole is positioned on the back wall of the container.

      11. Fit and lock the suction head.

      Cleaning/replacing the cooling air filter

      1. Allow the appliance to cool down.

      2. Unlock the cooling air flaps with a screwdriver and fold them out.


      3. Clean (vacuum, wash) or replace the cooling air filter.

      4. Fold the cooling air flaps in and latch it into place.

      Cleaning the electrodes

      1. Unlock and remove the suction head.

      2. Clean the electrodes with a brush.

      3. Fit and lock the suction head.

      Troubleshooting guide

      DANGER

      Danger of electric shock

      Injuries due to touching live parts

      Switch off the device.Remove the mains plug.

      Note

      The device must be switched off immediately if a malfunction occurs (e.g. filter breakage). The malfunction must be eliminated before switching the device on again.

      • Suction turbine does not start up 

      • Suction turbine switches off 

      • Suction turbine does not switch on again after emptying the container 

      • Suction power decreases 

      • Escaping dust when vacuuming 

      • The automatic switch-off mechanism (wet vacuum cleaning) does not trigger 

      • Horn sounds - intermittent tone 

      • Horn sounds - continuous tone 

      • Automatic filter dedusting not working 

      • The automatic filter dedusting function cannot be switched off 

      • The automatic filter dedusting function cannot be switched on 

      Suction turbine does not start up

      Remedy:

      1. Check the socket and the power supply fuse.

      2. Check the mains cable, mains plug, electrodes and power socket on the device.

      3. Switch on the device.

      Suction turbine switches off

      Remedy:

      1. Empty the container.

      2. Fit the new flat fold filter.

      Suction turbine does not switch on again after emptying the container

      Remedy:

      1. Switch off the device and wait for 5 seconds. Switch on the device.

      2. Clean the electrodes with a brush.

      Suction power decreases

      Remedy:

      1. Remove any blockages from the suction nozzle, suction pipe, suction hose or flat fold filter.

      2. Dispose of the filled safety filter bag.

      3. Dispose of the filled dust bag.

      4. Correctly engage the filter cover.

      5. Replace the flat fold filter.

      6. NT 50/1 only: Check the drain hose for leaks.

      Escaping dust when vacuuming

      Remedy:

      1. Check that the flat fold filter is correctly fitted and correct if necessary.


      2. Replace the flat fold filter.

      The automatic switch-off mechanism (wet vacuum cleaning) does not trigger

      Remedy:

      1. Clean the electrodes with a brush.

      2. Continuously monitor the filling level when vacuuming non-conductive liquids.

      Horn sounds - intermittent tone

      Remedy:

      1. Set the turn switch to the correct hose cross-section.

      2. The safety filter bag must be replaced when it is full and the air flow drops below the specified minimum flow rate.

      3. The dust bag must be replaced when it is full and the air flow drops below the specified minimum flow rate.

      4. Replace the flat fold filter.

      Horn sounds - continuous tone

      Remedy:

      1. Allow the device to cool down. Clean/replace the cooling air filter.

      Automatic filter dedusting not working

      Remedy:

      1. Suction hose not connected.

      The automatic filter dedusting function cannot be switched off

      Remedy:

      1. Contact Customer Service.

      The automatic filter dedusting function cannot be switched on

      Remedy:

      1. Contact Customer Service.

      Customer Service department

      If the malfunction cannot be corrected, the device must be checked by the Customer Service department.

      • Suction turbine does not start up 

      • Suction turbine switches off 

      • Suction turbine does not switch on again after emptying the container 

      • Suction power decreases 

      • Escaping dust when vacuuming 

      • The automatic switch-off mechanism (wet vacuum cleaning) does not trigger 

      • Horn sounds - intermittent tone 

      • Horn sounds - continuous tone 

      • Automatic filter dedusting not working 

      • The automatic filter dedusting function cannot be switched off 

      • The automatic filter dedusting function cannot be switched on 

      Suction turbine does not start up

      Remedy:

      1. Check the socket and the power supply fuse.

      2. Check the mains cable, mains plug, electrodes and power socket on the device.

      3. Switch on the device.

      Suction turbine switches off

      Remedy:

      1. Empty the container.

      2. Fit the new flat fold filter.

      Suction turbine does not switch on again after emptying the container

      Remedy:

      1. Switch off the device and wait for 5 seconds. Switch on the device.

      2. Clean the electrodes with a brush.

      Suction power decreases

      Remedy:

      1. Remove any blockages from the suction nozzle, suction pipe, suction hose or flat fold filter.

      2. Dispose of the filled safety filter bag.

      3. Dispose of the filled dust bag.

      4. Correctly engage the filter cover.

      5. Replace the flat fold filter.

      6. NT 50/1 only: Check the drain hose for leaks.

      Escaping dust when vacuuming

      Remedy:

      1. Check that the flat fold filter is correctly fitted and correct if necessary.


      2. Replace the flat fold filter.

      The automatic switch-off mechanism (wet vacuum cleaning) does not trigger

      Remedy:

      1. Clean the electrodes with a brush.

      2. Continuously monitor the filling level when vacuuming non-conductive liquids.

      Horn sounds - intermittent tone

      Remedy:

      1. Set the turn switch to the correct hose cross-section.

      2. The safety filter bag must be replaced when it is full and the air flow drops below the specified minimum flow rate.

      3. The dust bag must be replaced when it is full and the air flow drops below the specified minimum flow rate.

      4. Replace the flat fold filter.

      Horn sounds - continuous tone

      Remedy:

      1. Allow the device to cool down. Clean/replace the cooling air filter.

      Automatic filter dedusting not working

      Remedy:

      1. Suction hose not connected.

      The automatic filter dedusting function cannot be switched off

      Remedy:

      1. Contact Customer Service.

      The automatic filter dedusting function cannot be switched on

      Remedy:

      1. Contact Customer Service.

      Disposal

      At the end of its service life, the device is to be disposed of in accordance with statutory regulations.

      Warranty

      The warranty conditions issued by our relevant sales company apply in all countries. We shall remedy possible malfunctions on your appliance within the warranty period free of cost, provided that a material or manufacturing flaw is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.

      Further information can be found at: www.kaercher.com/dealersearch

      Further warranty information (if available) can be found in the service area of your local Kärcher website under "Downloads".

      Accessories and spare parts

      DANGER

      Risk when used with non-permitted accessories

      Risk of explosion

      Only use the accessories approved by the manufacturer. The use of other accessories can cause a risk of explosion.

      Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.

      Information on accessories and spare parts can be found at www.kaercher.com.

      EU Declaration of Conformity

      We hereby declare that the product named below complies with the relevant provisions of the directives and regulations listed. This declaration is invalidated by any changes made to the product that are not approved by us.

      Product: Wet/dry vacuum cleaner (ACD)

      Type: 1.148-xxx

      Directives and Regulations

      2006/42/EC (+2009/127/EC)

      2011/65/EU

      2014/30/EU

      Harmonised standards used

      EN IEC 63000: 2018

      EN 55014-1: 2017 + A11: 2020

      EN 55014-2: 1997 + A1: 2001 + A2: 2008

      EN 60335-1

      EN 60335-2-69

      EN 61000-3-2: 2014

      EN 61000-3-3: 2013

      EN 62233: 2008

      Non-harmonised standards

      IEC 60335-1: 2020

      IEC 60335-2-69: 2021

      National standards used

      TRGS 519

      The signatories act on behalf of and with the authority of the company management.


      Documentation supervisor:

      S. Reiser

      Alfred Kärcher SE & Co. KG

      Alfred-Kärcher-Str. 28 - 40

      71364 Winnenden (Germany)

      Ph.: +49 7195 14-0

      Fax: +49 7195 14-2212

      Winnenden, 2023/10/18

      Technical data

      • NT 30/1 Tact Te H ACD 

      • NT 40/1 Tact Te H ACD 

      • NT 50/1 Tact Te H ACD 

      NT 30/1 Tact Te H ACD

      Electrical connection
      Mains voltage
      220-240 V
      Phase
      1 ~
      Power frequency
      50-60 Hz
      Degree of protection
      IPX4
      Protection class
      I
      Nominal power
      1200 W
      Maximum power
      1380 W
      Power rating of the device socket (EU)
      25-2200 W
      Power rating of the device socket (GB)
      25-1800 W
      Power rating of the device socket (CH)
      25-1100 W
      Power rating of the device socket (AU)
      25-1200 W
      Device performance data
      Tank content
      31 l
      Fluid filling quantity
      17 l
      Air quantity (max.) with suction hose diameter 35 mm and length 5.0 m
      137,7 (38,3) m3/h (l/s)
      Air quantity (max., suction motor)
      266 m3/h
      Depression (max.) with suction hose diameter 35 mm and length 5.0 m
      21,6 (216,5) kPa (mbar)
      Vacuum (max., suction motor)
      27,3 (273) kPa (mbar)
      Dimensions and weights
      Typical operating weight
      14,4 kg
      Length x width x height
      560 x 370 x 580 mm
      Filter area of flat fold filter (PTFE H)
      0,5 m2
      Filter area of flat fold filter (GF)
      0,74 m2
      Diameter of the suction hose
      21 / 27 / 32 / 35 / 40 mm
      Length of the suction hose
      4,0 / 5,0 m
      Determined values in acc. with EN/IEC 60335-2-69
      Sound pressure level LpA
      69 dB(A)
      Uncertainty KpA
      2 dB(A)
      Hand-arm vibration value
      <2,5 m/s2
      Uncertainty K
      0,2 m/s2
      Mains cable
      Power cord type
      H07RN-F 3x1,5 mm2
      Part number (EU)
      6.650-665.0
      Part number (GB)
      6.650-728.0
      Part number (CH)
      6.650-726.0
      Part number (AU)
      6.650-727.0
      Cable length
      7,5 m

      NT 40/1 Tact Te H ACD

      Electrical connection
      Mains voltage
      220-240 V
      Phase
      1 ~
      Power frequency
      50-60 Hz
      Degree of protection
      IPX4
      Protection class
      I
      Nominal power
      1200 W
      Maximum power
      1380 W
      Power rating of the device socket (EU)
      25-2200 W
      Power rating of the device socket (GB)
      25-1800 W
      Power rating of the device socket (CH)
      25-1100 W
      Power rating of the device socket (AU)
      25-1200 W
      Device performance data
      Tank content
      39 l
      Fluid filling quantity
      24 l
      Air quantity (max.) with suction hose diameter 35 mm and length 5.0 m
      137,7 (38,3) m3/h (l/s)
      Air quantity (max., suction motor)
      266 m3/h
      Depression (max.) with suction hose diameter 35 mm and length 5.0 m
      21,6 (216,5) kPa (mbar)
      Vacuum (max., suction motor)
      27,3 (273) kPa (mbar)
      Dimensions and weights
      Typical operating weight
      15,1 kg
      Length x width x height
      560 x 370 x 655 mm
      Filter area of flat fold filter (PTFE H)
      0,5 m2
      Filter area of flat fold filter (GF)
      0,74 m2
      Diameter of the suction hose
      21 / 27 / 32 / 35 / 40 mm
      Length of the suction hose
      4,0 / 5,0 m
      Determined values in acc. with EN/IEC 60335-2-69
      Sound pressure level LpA
      68 dB(A)
      Uncertainty KpA
      2 dB(A)
      Hand-arm vibration value
      <2,5 m/s2
      Uncertainty K
      0,2 m/s2
      Mains cable
      Power cord type
      H07RN-F 3x1,5 mm2
      Part number (EU)
      6.650-665.0
      Part number (GB)
      6.650-728.0
      Part number (CH)
      6.650-726.0
      Part number (AU)
      6.650-727.0
      Cable length
      7,5 m

      NT 50/1 Tact Te H ACD

      Electrical connection
      Mains voltage
      220-240 V
      Phase
      1 ~
      Power frequency
      50-60 Hz
      Degree of protection
      IPX4
      Protection class
      I
      Nominal power
      1200 W
      Maximum power
      1380 W
      Power rating of the device socket (EU)
      25-2200 W
      Power rating of the device socket (GB)
      25-1800 W
      Power rating of the device socket (CH)
      25-1100 W
      Power rating of the device socket (AU)
      25-1200 W
      Device performance data
      Tank content
      51 l
      Fluid filling quantity
      35 l
      Air quantity (max.) with suction hose diameter 35 mm and length 5.0 m
      137,7 (38,3) m3/h (l/s)
      Air quantity (max., suction motor)
      266 m3/h
      Depression (max.) with suction hose diameter 35 mm and length 5.0 m
      21,6 (216,5) kPa (mbar)
      Vacuum (max., suction motor)
      27,3 (273) kPa (mbar)
      Dimensions and weights
      Typical operating weight
      19,6 kg
      Length x width x height
      640 x 370 x 1045 mm
      Filter area of flat fold filter (PTFE H)
      0,5 m2
      Filter area of flat fold filter (GF)
      0,74 m2
      Diameter of the suction hose
      21 / 27 / 32 / 35 / 40 mm
      Length of the suction hose
      4,0 / 5,0 m
      Determined values in acc. with EN/IEC 60335-2-69
      Sound pressure level LpA
      68 dB(A)
      Uncertainty KpA
      2 dB(A)
      Hand-arm vibration value
      <2,5 m/s2
      Uncertainty K
      0,2 m/s2
      Mains cable
      Power cord type
      H07RN-F 3x1,5 mm2
      Part number (EU)
      6.650-665.0
      Part number (GB)
      6.650-728.0
      Part number (CH)
      6.650-726.0
      Part number (AU)
      6.650-727.0
      Cable length
      7,5 m
      <BackPage>

      Filtersysteme / Filter Systems / Système de filtres

       
       
       
       
      Flachfaltenfilter (PTFE H) *
      Flat pleated filter (PTFE H) *
      Filtre plat à plis (PTFE H) *
      Flachfaltenfilter (GF) *
      Flat pleated filter (GF) *
      Filtre plat à plis (GF) *
      Sicherheitsfiltersack
      Safety filter sack
      Sac filtrant de sécurité
      Entsorgungsbeutel
      Disposal bag
      Sachet d’élimination
      Bestellnummer
      Order No.
      Numéro de référence
      NT 30/1
      6.907-671.0
      6.904-242.0
      (Materialkennzeichnung B)
      (material marking B)
      (marquage du matériau B)
      2.889-183.0
      2.889-231.0
      Bestellnummer
      Order No.
      Numéro de référence
      NT 40/1, NT 50/1
      6.907-671.0
      6.904-242.0
      (Materialkennzeichnung B)
      (material marking B)
      (marquage du matériau B)
      2.889-184.0
      2.889-231.0
      Menge
      Quantity
      Quantité
      1
      1
      5
      10
      Normalstäube
      Normal dust
      Poussières normales
      x
      x
      x
      x
      Feinstäube
      Fine dust
      Poussières fines
      x
      x
      x
      Abrasive Stäube
      Abrasive dust
      Poussières abrasives
      x
      x
      x
      x
      Flüssigkeiten, nasser Schmutz
      Liquids, wet dirt
      Liquides, saletès humides
      x
      x

      * Staubklasse H, Rückhaltevermögen ≥ 99,995 %

      * Dust class H, Retention ≥ 99,995 %

      * Classe de poussière H, Conservation ≥ 99,995 %


       

        

       