LogoAir Blower AB 28 ClassicAir Blower AB 40 Classic
  • General notes
  • Intended use
  • Environmental protection
  • Accessories and spare parts
  • Hazard levels
  • Safety instructions
  • Description of the unit
    • Air Blower AB 28 Classic
    • Air Blower AB 40 Classic
  • Operation
    • Set up and align device
    • Control panel
      • Power switch
      • Timer clock
    • Switching on the device
    • Drying
    • Switching off the device
  • Transport
  • Storage
  • Care and service
  • Troubleshooting guide
    • Blower does not run

  • Customer Service department
    • Blower does not run

  • Warranty
  • Technical data
    • AB 28 Classic *KAP
    • AB 28 Classic *CN
    • AB 40 Classic *KAP
    • AB 40 Classic *CN

      Air Blower AB 28 Classic
      Air Blower AB 40 Classic

      97711940 (12/24)

      General notes

      Read the original instructions before using the device for the first time and act in accordance with it. Keep the original instructions for future reference or for future owners.

      • If the operating instructions and safety instructions are not observed, the device can be damaged and dangers could arise for users and other persons.

      • Notify the dealer immediately in the case of shipping damage.

      • Check the package contents when unpacking for missing accessories or for damage.

      Intended use

      • This blower is intended for drying floors, walls and ceilings and furniture, as well as wet-cleaned rugs/carpets.

      • This device is intended for use in private households and for commercial use.

      Any other use is considered as improper use. The manufacturer is not responsible for any resultant damage. The risk is borne by the user alone.

      Environmental protection

      The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.

      Electrical and electronic devices contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which - if handled or disposed of incorrectly - can pose a potential danger to human health and the environment. However, these components are required for the correct operation of the device. Devices marked by this symbol are not allowed to be disposed of together with the household rubbish.

      Notes on the content materials (REACH)

      Current information on content materials can be found at: www.kaercher.de/REACH

      Accessories and spare parts

      Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.

      Information on accessories and spare parts can be found at www.kaercher.com.

      Hazard levels

      DANGER

      Indication of an imminent threat of danger that will lead to severe injuries or even death.

      WARNING

      Indication of a potentially dangerous situation that may lead to severe injuries or even death.

      CAUTION

      Indication of a potentially dangerous situation that may lead to minor injuries.

      ATTENTION

      Indication of a potentially dangerous situation that may lead to damage to property.

      Safety instructions

      DANGER

      Never touch the mains plug or the device with wet hands.

      DANGER

      Check the mains cable regularly for damage such as for cracks forming or signs of ageing. Replace the mains cable if it is damaged before continued use.

      DANGER

      No changes may be made to the device.

      WARNING

      Only use the device for its proper use. Take into account the local conditions and beware of third parties, in particular children, when working with the device.

      WARNING

      Only people who have been instructed on how to use the device, or have proven their ability to operate it, and have been explicitly instructed to use it, must use the device.

      WARNING

      The device is not intended for use by persons with restricted physical, sensory or mental abilities or those lacking in experience and / or lacking in knowledge.

      WARNING

      Children must be supervised to prevent them from playing with the appliance.

      WARNING

      Children must not operate the device.

      CAUTION

      Never leave the device unattended when it is not switched and with the mains plug still connected.

      CAUTION

      Check the device with the equipment prior to each use to make sure it is safe and working correctly. Only use the device when it is in a correct condition.

      CAUTION

      Only have repairs and installation of spare parts performed by the approved Customer Service in order to prevent any hazards.

      ATTENTION

      The device must not be operated or left outdoors.

      Description of the unit

      Air Blower AB 28 Classic


      1. Carrying handle
      2. Control panel
      3. Device housing
      4. Fan grille at air exit grid
      5. Air exit
      6. Rubber foot
      7. Wheels
      8. Air inlet
      9. Cable storage

      Air Blower AB 40 Classic


      1. Carrying handle
      2. Control panel
      3. Device housing
      4. Fan grille at air exit grid
      5. Air exit
      6. Rubber foot
      7. Wheels
      8. Air inlet
      9. Cable storage
      10. Transport handle

      Operation

      DANGER

      Turbulence of gasses and dusts

      Risk of fire and explosion

      Do not operate the device near combustible gasses and explosive dusts.

      DANGER

      Poisoning by exhaust gas

      Sucked-in exhaust gas contaminates the environment.

      Do not operate the device near open flames.Prevent exhaust emissions near the air inlet.

      WARNING

      Injuries due to strong suction

      The device creates strong suction at the air inlet, meaning that objects, items of clothing or hair could be sucked in.

      Keep a safe distance from the air inlet.

      WARNING

      Injuries due to strong air streaming

      The device creates strong air streaming at the air exit, meaning that sucked-in objects could be ejected at high speed.

      Keep a safe distance from the air exit.

      Note

      Take suitable measures to avoid the device moving around on smooth floors.

      Note

      When setting up the device, ensure that the fan grilles are not blocked.

      1. Open doors and windows as wide as possible to improve ventilation.

      Set up and align device

      AB 28 Classic :


      AB 40 Classic :


      Set up and align device stably on level ground.

      Control panel

      Air Blower AB 28 Classic


      Air Blower AB 40 Classic


      1. Power switch
      2. Timer clock (AB 40 Classic only)

      Power switch

      O
      Off
      1
      Minimum power
      2
      Medium power
      3
      Maximum power

      Timer clock

      1...180
      Minutes

      Switching on the device

      1. Connect the mains plug.

      2. Switch on the device.

      Drying

      1. AB 40 Classic only: Adjust the timer clock to the desired time.

      2. Carry out drying.

      Switching off the device

      1. Switch off the device.

      2. Pull out the mains plug.

      Transport

      CAUTION

      Failure to observe the weight

      Risk of injury and damage

      Be aware of the weight of the device during transportation.
      1. Wind the mains cable around the cable storage.

      2. When transporting the device in vehicles, secure it to prevent it from slipping or overturning in accordance with the respective valid guidelines.

      Storage

      CAUTION

      Failure to observe the weight

      Risk of injury and damage

      Be aware of the weight of the device during storage.

      The device may only be operated indoors.

      Care and service

      DANGER

      Danger of electric shock

      Injuries due to touching live parts

      Switch off the device.Remove the mains plug.

      CAUTION

      Device continues to run after switch-off

      Risk of injury from blower continuing to run

      Wait until the blower has come to a complete standstill before performing maintenance or repair work.
      1. Check the fan grilles daily for soiling, clean if necessary.

      2. Regularly clean the device surface with a moist cloth.

      Troubleshooting guide

      DANGER

      Danger of electric shock

      Injuries due to touching live parts

      Switch off the device.Remove the mains plug.

      CAUTION

      Device continues to run after switch-off

      Risk of injury from blower continuing to run

      Wait until the blower has come to a complete standstill before performing maintenance or repair work.
      • Blower does not run 

      Blower does not run

      Remedy:

      1. Check the socket and the power supply fuse.

      2. Check the mains cable and the mains plug of the device.

      3. Switch on the device.

      Customer Service department

      If the malfunction cannot be corrected, the device must be checked by the Customer Service department.

      • Blower does not run 

      Blower does not run

      Remedy:

      1. Check the socket and the power supply fuse.

      2. Check the mains cable and the mains plug of the device.

      3. Switch on the device.

      Warranty

      The warranty conditions issued by our relevant sales company apply in all countries. We shall remedy possible malfunctions on your appliance within the warranty period free of cost, provided that a material or manufacturing flaw is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.

      Further information can be found at: www.kaercher.com/dealersearch

      Further warranty information (if available) can be found in the service area of your local Kärcher website under "Downloads".

      Technical data

      • AB 28 Classic *KAP 

      • AB 28 Classic *CN 

      • AB 40 Classic *KAP 

      • AB 40 Classic *CN 

      AB 28 Classic *KAP

      Electrical connection
      Voltage
      220-240 V
      Frequency
      50-60 Hz
      Phase
      1 ~
      Dimensions and weights
      Typical operating weight
      8.5 kg
      Length
      467 mm
      Width
      440 mm
      Height
      513 mm
      Device performance data
      Power
      550 W
      Air flow rate (level 1/2/3)
      1500/1750/2100 m3/h
      Blower speed (level 1/2/3)
      950/1150/1300 rpm
      Air flow speed (level 1/2/3)
      12/14/17 m/s
      Mains cable
      Cable length
      7 m

      AB 28 Classic *CN

      Electrical connection
      Voltage
      220 V
      Frequency
      50 Hz
      Phase
      1 ~
      Dimensions and weights
      Typical operating weight
      8.5 kg
      Length
      467 mm
      Width
      440 mm
      Height
      513 mm
      Device performance data
      Power
      550 W
      Air flow rate (level 1/2/3)
      1500/1750/2100 m3/h
      Blower speed (level 1/2/3)
      950/1150/1300 rpm
      Air flow speed (level 1/2/3)
      12/14/17 m/s
      Mains cable
      Cable length
      5 m

      AB 40 Classic *KAP

      Electrical connection
      Voltage
      220-240 V
      Frequency
      50-60 Hz
      Phase
      1 ~
      Dimensions and weights
      Typical operating weight
      10.7 kg
      Length
      467 mm
      Width
      440 mm
      Height
      513 mm
      Device performance data
      Power
      700 W
      Air flow rate (level 1/2/3)
      2100/2400/2700 m3/h
      Blower speed (level 1/2/3)
      1100/1300/1400 rpm
      Air flow speed (level 1/2/3)
      17/20/22 m/s
      Mains cable
      Cable length
      7 m

      AB 40 Classic *CN

      Electrical connection
      Voltage
      220 V
      Frequency
      50 Hz
      Phase
      1 ~
      Dimensions and weights
      Typical operating weight
      10.7 kg
      Length
      467 mm
      Width
      440 mm
      Height
      513 mm
      Device performance data
      Power
      700 W
      Air flow rate (level 1/2/3)
      2100/2400/2700 m3/h
      Blower speed (level 1/2/3)
      1100/1300/1400 rpm
      Air flow speed (level 1/2/3)
      17/20/22 m/s
      Mains cable
      Cable length
      5 m