LogoHDS 18/18-4 S Classic
  • General notes
  • Environmental protection
    • Supplementary environmental protection instructions
  • Overview of the device
    • Device description
    • Control panel
  • Symbols on the device
  • Intended use
    • Water supply limit values
  • Safety instructions
  • Safety devices
    • Overflow valve with pressure switch
    • Safety valve
    • Water shortage safeguard
    • Exhaust gas thermostat
    • Flame monitoring
    • Overcurrent protection
    • Temperature sensor
    • Safety latch
    • Readiness time
  • Initial startup
    • Check the oil level in the high-pressure pump
    • Installing accessories
    • System care
      • Define system care
      • Refilling the system care
    • Refuelling
    • Water connection
    • Electrical connection
  • Operation
    • Opening/closing the high-pressure gun
    • Changing nozzles
    • Switching on the device
    • Setting the working pressure and flow rate
      • Pressure/quantity regulator of the pump unit
      • Pressure/quantity regulator on the high-pressure gun
    • Cleaning
    • Cold water operation
    • Eco level
    • Operation with hot water
      • Recommended cleaning temperatures
    • Interrupting operation
    • Switching off the device
    • Storing the device
    • Frost protection
    • Shutting down
      • Draining the water
      • Flushing device with antifreeze
  • Transport
    • Crane transport
  • Storage
  • Care and maintenance
    • Safety inspection/maintenance contract
    • Maintenance intervals
      • Weekly
      • Every 500 operating hours, at least annually
    • Maintenance work
      • Cleaning the water inlet filter
      • Cleaning the fine filter
      • Cleaning the fuel sieve
      • Clean the fuel filter
      • Changing the oil
  • Troubleshooting guide
    • Meaning of the LED indicators
      • Burner does not ignite or flame goes out during operation

      • Service menu indicator light (red) flashes 1x

      • Service indicator light flashes 1x

      • Service indicator light flashes 2x

      • Service indicator light flashes 3x

      • Service indicator light flashes 4x

      • Service indicator light flashes 5x

      • The service indicator light flashes 6x

      • Service indicator light flashes 7x

      • Service indicator light flashes 8x

      • System care LED lights up

      • Pump not reaching the required pressure
      • High-pressure pump knocking
      • The device keeps turning on and off when the high-pressure gun is open.
      • The device does not switch off when the high-pressure gun is closed
    • Who is permitted to eliminate faults?
      • Burner does not ignite or flame goes out during operation

      • Service menu indicator light (red) flashes 1x

      • Service indicator light flashes 1x

      • Service indicator light flashes 2x

      • Service indicator light flashes 3x

      • Service indicator light flashes 4x

      • Service indicator light flashes 5x

      • The service indicator light flashes 6x

      • Service indicator light flashes 7x

      • Service indicator light flashes 8x

      • System care LED lights up

      • Pump not reaching the required pressure
      • High-pressure pump knocking
      • The device keeps turning on and off when the high-pressure gun is open.
      • The device does not switch off when the high-pressure gun is closed
    • Troubleshooting
      • Burner does not ignite or flame goes out during operation

      • Service menu indicator light (red) flashes 1x

      • Service indicator light flashes 1x

      • Service indicator light flashes 2x

      • Service indicator light flashes 3x

      • Service indicator light flashes 4x

      • Service indicator light flashes 5x

      • The service indicator light flashes 6x

      • Service indicator light flashes 7x

      • Service indicator light flashes 8x

      • System care LED lights up

      • Pump not reaching the required pressure
      • High-pressure pump knocking
      • The device keeps turning on and off when the high-pressure gun is open.
      • The device does not switch off when the high-pressure gun is closed
    • Customer Service department
      • Burner does not ignite or flame goes out during operation

      • Service menu indicator light (red) flashes 1x

      • Service indicator light flashes 1x

      • Service indicator light flashes 2x

      • Service indicator light flashes 3x

      • Service indicator light flashes 4x

      • Service indicator light flashes 5x

      • The service indicator light flashes 6x

      • Service indicator light flashes 7x

      • Service indicator light flashes 8x

      • System care LED lights up

      • Pump not reaching the required pressure
      • High-pressure pump knocking
      • The device keeps turning on and off when the high-pressure gun is open.
      • The device does not switch off when the high-pressure gun is closed
  • Warranty
  • Accessories and spare parts
  • Declaration of Conformity
  • Technical data

      HDS 18/18-4 S Classic

      59802380 (10/24)

      General notes

      Read these original instructions and the enclosed safety instructions before using the device for the first time. Act in accordance with them.

      Keep both books for future reference or for future owners.

      • If the operating instructions and safety instructions are not observed, the device can be damaged and dangers could arise for users and other persons.

      • Notify the dealer immediately in the case of shipping damage.

      • Check the package contents when unpacking for missing accessories or for damage. Scope of delivery see illustration A.

      • At operating elevations of approx. 800 m above sea level or higher, please contact your dealer to have the burner setting adjusted to the elevation and reduced oxygen content.

      Environmental protection

      The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.

      Electrical and electronic devices contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which - if handled or disposed of incorrectly - can pose a potential danger to human health and the environment. However, these components are required for the correct operation of the device. Devices marked by this symbol are not allowed to be disposed of together with the household rubbish.

      Notes on the content materials (REACH)

      Current information on content materials can be found at: www.kaercher.de/REACH

      Supplementary environmental protection instructions

      Please do not allow engine oil, heating oil, diesel and petrol to enter the environment. Please protect the ground and dispose of old oil in an environmentally friendly manner.

      Overview of the device

      Device description


      1. Burner
      2. Burner blower
      3. Fuel pump solenoid valve
      4. Fuel pump
      5. Water shortage safeguard and safety valve
      6. Type plate
      7. Filling hole for fuel (fuel cap)
      8. Water connection
      9. Fuel filter
      10. Fuel sieve
      11. Fuel tank
      12. Electric motor
      13. Water inlet filter
      14. Pressure/quantity regulator of the pump unit
      15. Pressure switch
      16. Oil level gauge
      17. Oil drain screw
      18. Oil filler plug
      19. Pump unit
      20. Power supply cable
      21. Fine filter (water)
      22. High-pressure connection
      23. Temperature sensor
      24. Float container
      25. Lid of float container
      26. Filling hole for system care RM 110 / RM 111
      27. Hose switch
      28. Ignition transformer
      29. Support for high-pressure gun with spray lance
      30. High-pressure hose
      31. Steering roller with parking brake
      32. Fastening screw for cover
      33. Union nut
      34. Empty indicator sensor for fuel
      35. Control panel
      36. Cover
      37. Pressure/quantity regulator on the high-pressure gun
      38. Safety lever
      39. Trigger
      40. High-pressure gun
      41. High-pressure nozzle
      42. Spray lance
      43. Safety latch of the high-pressure gun
      44. Cable clips
      45. Brace for crane transport
      46. Frame

      Control panel


      0 = Off

      1. Power switch
      2. Operating mode: Cold water operation
      3. Operating mode: Hot water operation (e = Eco level, hot water max. 60°C)
      4. Service (only for customer service)
      5. Code for information
      6. Rotation direction indicator light
      7. Service indicator light
      8. Standby mode indicator light
      9. Fuel indicator light
      10. System care indicator light

      Symbols on the device

       
      Do not point the high-pressure jet at people, animals, live electrical equipment or at the device itself.
      Protect the device from frost.
       
      Danger of injury from electrical voltage. Only qualified electricians or authorised and qualified technical specialists are permitted to work on the electrical systems.
       
      According to applicable regulations, the device must never be used with the drinking water network without a system separator. Ensure that the connection to your house water system, with which the high-pressure cleaner is operated, is equipped with a system separator according to EN 12729 type BA. Water that has flowed through a system separator is classified as undrinkable.
      Always connect the system separator to the water supply and never directly to the device.
      Health risk from poisonous exhaust gases. Never inhale the exhaust gases.
      Risk of burns from hot surfaces.
       
      Code for information

      Intended use

      Only use the device for cleaning, e.g. machines, vehicles, buildings, tools, façades, terraces and garden equipment.

      DANGER

      Use at petrol stations or other hazard zones

      Risk of injury

      Adhere to the respective safety regulations.

      Note

      Do not allow waste water containing mineral oil to penetrate soil, waterways or the sewage system. Only wash the motor or the undercarriage in suitable places with an oil separator.

      Water supply limit values

      ATTENTION

      Dirty water

      Premature wear and tear or deposits in the device

      Supply the device using only clean water, or recycled water that does not exceed the specified limit values.

      The following limit values apply to the water supply:

      • pH value: 6.5-9.5

      • Electrical conductivity: Conductivity of fresh water + 1200 µS/cm, maximum conductivity 2000 µS/cm

      • Settleable particles (sample volume 1 l, settling time 30 minutes): < 0.5 mg/l

      • Filterable particles: < 50 mg/l, no abrasive substances

      • Hydrocarbons: < 20 mg/l

      • Chloride: < 300 mg/l

      • Sulphate: < 240 mg/l

      • Calcium: < 200 mg/l

      • Total hardness: < 28 °dH, < 50° TH, < 500 ppm (mg CaCO3/l)

      • Iron: < 0.5 mg/l

      • Manganese: < 0.05 mg/l

      • Copper: < 2 mg/l

      • Active chloride: < 0.3 mg/l

      • Free of unpleasant odours

      Safety instructions

      The following safety instructions apply to the device:

      • Observe the respectively applicable national regulations for liquid jet cleaners.

      • Observe the respectively applicable national accident prevention regulations. Liquid jet cleaners must be tested regularly and the results of the test recorded in writing.

      • Note that the heating system in the device is classified as a furnace. Furnaces must be inspected regularly according to the applicable national regulations.

      • No modifications may be made to the device or accessories.

      • To avoid hazards from excessive temperatures, you must set the pressure/quantity regulator of the pump unit to MAX at work temperatures above 60 °C.

      Safety devices

      Safety devices protect the user and may not be disabled or functionally circumvented.

      Overflow valve with pressure switch

      • When reducing the water volume at the pump head or with the pressure/quantity regulator on the high-pressure gun, the overflow valve opens and part of the water flows back to the pump suction side.

      • When the high-pressure gun is closed, the pressure relief valve opens and all the water flows back to the pump suction side. The pressure switch on the overflow valve sends a signal to the control unit, which switches the pump off after approx. 30 seconds of after-running time.

      • If the high-pressure gun is opened again, the pressure switch at the overflow valve switches the pump on again.

      • The overflow valve is set and sealed at the factory. The adjustment is performed only by customer service.

      Safety valve

      • The safety valve opens if the system pressure is too high.

      • The safety valve is adjusted and sealed at the factory. The adjustment is performed only by customer service.

      Water shortage safeguard

      The water shortage safeguard prevents the burner from switching on when there is a lack of water.

      Exhaust gas thermostat

      The exhaust gas thermostat switches the device off when the emission temperature is too high.

      Flame monitoring

      The flame monitoring system monitors the brightness of the flame on the burner and switches the burner off in the event of a fault.

      Overcurrent protection

      The device current is limited by the HDS control circuit board. In addition, the fan motor and the pump motor are each protected by a winding protection contact.

      Temperature sensor

      The temperature sensor switches the burner off when the set water temperature is reached.

      Safety latch

      The safety catch on the high-pressure gun prevents the device from being switched on inadvertently.

      Readiness time

      If the device is not used for 30 minutes, the device switches off. The readiness time can be activated and deactivated by customer service via the service menu.

      Initial startup

      WARNING

      Damaged components

      Risk of injury

      Check that the device, accessories, supply lines and connections are in perfect condition. If the condition is not perfect, you may not use the device.
      1. Apply the parking brake.

      Check the oil level in the high-pressure pump

      ATTENTION

      Milky oil

      Device damage

      If the oil is milky, inform authorized Customer Service immediately.
      1. Place the device on a flat and level surface.

      2. Check the high-pressure pump oil level at the oil level display.

        The oil level must be in the middle of the oil level indication.

      3. Top up the oil if necessary.

      Installing accessories

      Note

      The EASY!Lock system connects components quickly and safely via a single turn of the quick-release thread.

      1. Connect the spray lance to the high-pressure gun and hand-tighten (EASY!Lock).


      2. Plug the high-pressure nozzle onto the spray lance.

      3. Fit the union nut and hand-tighten (EASY!Lock).

      4. Connect the high-pressure hose to the high-pressure gun and high-pressure connection of the device and tighten hand-tight (EASY!Lock).

      System care

      Define system care

      Note

      RM 110 prevents calcification of the heating coil in the presence of hard water.

      Note

      RM 111 prevents the formation of black water and cares for the pump in the presence of soft water.

      Water hardness (°dH)
      System care products to be used
      <3
      RM 111
      >3
      RM 110
      1. Determine the local water hardness via the local supply company or with a hardness tester (order number 6.768-004.0).

      Refilling the system care

      Note

      The system care is not included in the scope of delivery.

      • The system care is a highly effective agent for preventing calcification of the heating coil when operating with calcareous tap water. This is drip-fed dosed into the float container.

      • The dosage is set to medium water hardness at the factory. The device can be adjusted to the local water hardness by customer service.

      1. Refill the system care.

      Refuelling

      DANGER

      Unsuitable fuel

      Risk of explosion

      Only use diesel fuel or light heating oil. Unsuitable fuels, such as petrol, must not be used.

      ATTENTION

      Operation with an empty fuel tank

      Destruction of the fuel pump

      Never operate the device with an empty fuel tank.
      1. Open the tank cap.

      2. Refill the fuel.

      3. Close the tank cap.

      4. Wipe up the spilt fuel.

      Water connection

      • See the "Technical data" for the connected loads.

      Note

      The water supply hose is not included in the scope of delivery.

      1. Connect the supply hose (minimum length 7.5 m, minimum diameter 1") to the water connection of the device and to the water supply (e.g. water tap).

      2. Open the water inlet.

      Electrical connection

      DANGER

      Unsuitable electrical extension cables

      Electric shock

      Only use approved and appropriately marked electrical extension cables with a sufficient line cross section for outdoors.Make sure that the plug and coupling of an extension cable used are watertight.Always unroll extension cables completely.

      ATTENTION

      Exceeding the grid impedance

      Electrical shock in the event of a short-circuit

      The maximum permissible mains grid impedance at the electrical connection point (see Technical data) must not be exceeded.Contact your electricity supplier in the case of any uncertainties regarding the mains grid impedance at your electrical connection point.
      • For connected loads, see technical data and type plate.

      • The electrical connection must be carried out by an electrician and comply with IEC 60364-1.

      Operation

      DANGER

      Flammable fluids

      Risk of explosion

      Do not spray inflammable liquids.

      DANGER

      Operation without spray lance

      Risk of injury

      Never operate the device without the spray lance installed.Before each use, check that the spray lance is firmly seated. The screw connection of the spray lance must be tightened hand tight.

      DANGER

      High-pressure water jet

      Danger of injury

      Never fasten the trigger and safety lever in the actuated position.Do not use the high-pressure gun when the safety lever is damaged.Push the safety latch of the high-pressure gun forwards every time before starting work with the device.Hold the high-pressure gun and spray lance with both hands.

      DANGER

      Danger due to damaged mains cable

      Electric shock

      Make sure that the mains cable is not in contact with the burner (hot) during operation.

      ATTENTION

      Operation with an empty fuel tank

      Destruction of the fuel pump

      Never operate the device with an empty fuel tank.

      Opening/closing the high-pressure gun

      1. Opening the high-pressure gun: Actuate the safety lever and trigger.

      2. Closing the high-pressure gun: Release the safety lever and trigger.

      Changing nozzles

      1. Switch off the device and operate the high-pressure gun until the device is depressurized.

      2. Lock the high-pressure gun by pushing the safety latch forwards.

      3. Change the nozzle.

      Switching on the device

      1. Set the trigger to the operating mode. The standby mode indicator light lights up. The device starts up briefly and switches off as soon as the working pressure is reached.

        Note

        If the direction of rotation indicator light lights up during operation, switch off the device immediately and rectify the fault, see "Troubleshooting".

      2. Unlock the high-pressure gun by pushing the safety latch to the rear. When the high-pressure gun is actuated, the device switches on again.

        Note

        If no water comes out of the high-pressure nozzle, bleed the pump. See help in the event of malfunctions – device does not build up pressure.

      Setting the working pressure and flow rate

      Pressure/quantity regulator of the pump unit

      1. Turn the regulating spindle clockwise: Increase the working pressure (MAX).

      2. Turn the regulating spindle anticlockwise: Reduce the working pressure (MIN).

      Pressure/quantity regulator on the high-pressure gun

      DANGER

      Danger of a loose spray lance

      Risk of injury

      Take care to ensure that the spray lance screw connection does not release when adjusting the pressure/quantity control.

      Note

      If you want to work with reduced pressure over the long term, set the pressure on the pressure/quantity regulator of the pump unit.

      1. Set the power switch to max. 90 °C.

      2. Set the working pressure on the pressure/quantity regulator of the pump unit to the maximum value.

      3. Adjust the working pressure and flow rate by turning (variable) the pressure/quantity regulator on the high-pressure gun (+/-).

      Cleaning

      Note

      Always initially direct the high-pressure jet at the object to be cleaned from a distance and with low temperature to avoid damage due to excessive pressure or temperature.

      1. Set the cleaning temperature according to the surface to be cleaned.

      Cold water operation

      For removing light contamination and for rinsing, e.g. garden machines, terrace, tools.

      Eco level

      The device works in the most economical temperature range (max. 60 °C).

      Operation with hot water

      DANGER

      Hot water

      Risk of scalding

      Avoid contact with hot water.

      DANGER

      Danger due to excessive temperatures

      Danger of scalding

      To avoid hazards from excessive temperatures, you must set the pressure/quantity regulator of the pump unit to MAX at work temperatures above 60 °C.

      Note

      After operation with hot water, water droplets may occasionally escape from the safety valve due to the residual heat in the boiler.

      1. Set the power switch to the desired temperature.

      Recommended cleaning temperatures

      • 30-50 °C: Light soiling

      • Max. 60 °C: Soiling containing protein, e.g. in the food industry

      • 60-90 °C: Car cleaning, machine cleaning

      Interrupting operation

      1. Lock the high-pressure gun by pushing the safety latch forwards.

      Switching off the device

      DANGER

      Hot water hazard

      Risk of scalding

      After operation with hot water, the device must be operated with an opened gun with cold water for at least 2 minutes.
      1. Close the water inlet.

      2. Open the high-pressure gun.

      3. Switch on the pump with the power switch and let it run for 5-10 seconds.

      4. Close the high-pressure gun.

      5. Set the power switch to "0".

      6. Only pull the mains plug out of the socket only when your hands are dry.

      7. Remove the water connection.

      8. Actuate the high-pressure gun until the device is completely depressurised.

      9. Lock the high-pressure gun by pushing the safety latch forwards.

      Storing the device

      Note

      Do not kink the high-pressure hose or the electrical line.

      1. Insert the high-pressure gun in the support on the frame together with the spray lance.

      2. Roll up the high-pressure hose and the electrical line and hang them on the supports.

      Frost protection

      ATTENTION

      Frost hazard

      Destruction of the device through freezing water

      Store the device that has not been completely drained of water in a frost-free place.

      In the case of devices that are connected to a chimney, the ingress of cold air must be taken into account.

      ATTENTION

      Cold air entering through the chimney

      Risk of damage

      When the exterior temperatures are below 0 °C, disconnect the device from the chimney.
      1. Shut down the device if frost-free storage is not possible.

      Shutting down

      For longer breaks in operation or when frost-free storage is not possible:

      1. Drain the water.

      2. Flush the device with antifreeze.

      Draining the water

      1. Unscrew the water supply hose and the high-pressure hose.

      2. Unscrew the supply line at the boiler base and allow the heating coil to drain.

      3. Allow the device for run for a maximum of 1 minute until the pump and lines are empty.

      Flushing device with antifreeze

      Note

      Observe the handling instructions of the anti-freeze manufacturer.

      1. Pour a commercially available antifreeze into the float tank.

      2. Switch on the device (without burner) and allow it to run until the device is completely flushed.

      This also provides a certain degree of corrosion protection.

      Transport

      ATTENTION

      Improper transportation

      Risk of damage

      Protect the trigger of the high-pressure gun from damage.

      CAUTION

      Failure to observe the weight

      Risk of injury and damage

      Be aware of the weight of the device during transportation.
      1. Run a tensioning strap to secure the device between the wheel and the frame over the base plate. Observe the illustration.


      2. When transporting the device in vehicles, secure it to prevent it from slipping or overturning in accordance with the respectively applicable guidelines.

      Crane transport

      DANGER

      Improper crane transport

      Risk of injury from a falling device or falling objects

      Observe the local regulations for accident prevention, laws and safety instructions.The device may only be transported with a crane by persons instructed in the operation of the crane.Check the lifting gear for damage before each crane transport.Check the strut on the device for damage before each crane transport.Lift the device only at the middle of the crane transport strut.Do not use slinging chains.Secure the lifting gear against unintentional unhooking of the load.Remove the spray lance with high-pressure gun and other loose objects before transporting by crane.Do not transport any objects on the device during the lifting operation.Do not stand under the suspended load.Ensure that no persons are in the hazard zones of the crane.Do not leave the device handing unattended on the crane.
      1. Fasten the lifting device to the struts for crane transport of the device.


      Storage

      CAUTION

      Failure to observe the weight

      Risk of injury and damage

      Be aware of the weight of the device during storage.

      Care and maintenance

      DANGER

      Inadvertently starting up device, touching live components

      Risk of injury, electric shock

      Switch off the device before performing any work on the device.Remove the mains plug.
      1. Close the water inlet.

      2. Open the high-pressure gun.

      3. Switch on the pump with the power switch and let it run for 5-10 seconds.

      4. Close the high-pressure gun.

      5. Set the power switch to "0".

      6. Only pull the mains plug out of the socket only when your hands are dry.

      7. Remove the water connection.

      8. Actuate the high-pressure gun until the device is completely depressurised.

      9. Lock the high-pressure gun by pushing the safety latch forwards.

      10. Allow the device to cool down.

      Safety inspection/maintenance contract

      You can agree on regular safety inspections or close a maintenance contract with your dealer. Please seek advice on this.

      Maintenance intervals

      Weekly

      ATTENTION

      Milky oil

      Device damage

      If the oil is milky, inform authorized Customer Service immediately.
      1. Clean the water inlet filter.

      2. Clean the fine filter.

      3. Clean the fuel strainer.

      4. Clean the fuel filter.

      5. Check the oil level.

      6. Check the filling level of the system care container. Refill the system care if necessary.

      Every 500 operating hours, at least annually

      1. Change the oil.

      2. Have the device descaled by Customer Service.

      3. Have the device maintained by Customer Service.

      Maintenance work

      Cleaning the water inlet filter

      1. Depressurise the device.

      2. Remove the union nut on the water inlet filter and take out the filter inlay.


      3. Clean the filter inlay with clean water or compressed air.

      4. Assemble in the reverse order.

      Cleaning the fine filter

      1. Depressurise the device.

      2. Unscrew the water hose on the fine filter.


      3. Remove the union nut on the fine filter and take out the filter inlay.

      4. Clean the filter inlay with clean water or compressed air.

      5. Assemble in the reverse order.

      Cleaning the fuel sieve

      1. Knock out the fuel sieve. Do not allow fuel to enter the environment.

      Clean the fuel filter

      1. Release the 3 fastening screws of the cover and remove the cover.

      2. Remove the fuel filter.

      3. Clean the fuel filter.

      4. Remount the fuel filter.

      Changing the oil

      See the "Technical data" section for the oil filling quantity and type.

      1. Release the 3 fastening screws on the cover and remove the cover.

      2. Release the 2 fastening screws between the fuel tank and the electrical box.


      3. Lift the electrical box and push the fuel tank partially towards the burner fan. Support the electrical box on the motor.

      4. Place a suitable catch pan for approx. 1.5 litres of oil under the pump.

      5. Loosen the oil drain plug.

      6. Drain the oil into the catch pan. Unscrew the oil filler plug completely so that the oil can drain off more quickly and completely.

        Note

        Dispose of the old oil in an environmentally friendly manner or hand it over to an authorised collection point.

      7. Retighten the oil drain plug, torque 20-25 Nm.

      8. Slowly fill with new oil until the level is in the middle of the oil level display. The air bubbles must be able to escape.

      9. Screw in the oil filler plug.

      10. Push the fuel tank back into place.

      11. Reinstall in the in the reverse order.

      Troubleshooting guide

      DANGER

      Inadvertently starting up device, touching live components

      Risk of injury, electric shock

      Switch off the device before performing any work on the device.Remove the mains plug.

      Meaning of the LED indicators

      LED
      Blink code
      Meaning
      Service menu LED (red)
      -
      Direction of rotation (wrong rotating field)
      Service LED (red)
      lights up
      Carry out service/maintenance
      flashes 1x
      Leakage on the device
      flashes 2x
      Current/voltage fault:
      • Asymmetry

      • Over/under current

      • Over/undervoltage

      flashes 3x
      Winding protection contact fault
      flashes 4x
      Exhaust gas fault
      flashes 5x
      Water shortage / dry running
      flashes 6x
      Flame sensor LED too bright / too dark
      flashes 7x
      Water outlet temperature sensor fault
      flashes 8x
      Communication fault
      Operation LED (green)
      lights up
      Normal operation without faults
      flashes 1x
      Pump has been running continuously for 30 minutes
      flashes 2x
      Pump has been continuously inactive for 30 minutes
      System care LED (orange)
      lights up
      System care empty
      • Burner does not ignite or flame goes out during operation 

      • Service menu indicator light (red) flashes 1x 

      • Service indicator light flashes 1x 

      • Service indicator light flashes 2x 

      • Service indicator light flashes 3x 

      • Service indicator light flashes 4x 

      • Service indicator light flashes 5x 

      • The service indicator light flashes 6x 

      • Service indicator light flashes 7x 

      • Service indicator light flashes 8x 

      • System care LED lights up 

      • Pump not reaching the required pressure 

      • High-pressure pump knocking 

      • The device keeps turning on and off when the high-pressure gun is open. 

      • The device does not switch off when the high-pressure gun is closed 

      Burner does not ignite or flame goes out during operation

      Cause:

      Temperature controller set too low.

      Remedy:

      Operator

      1. Set the temperature regulator higher.

      Cause:

      Power switch is not set to warm water.

      Remedy:

      Operator

      1. Set the device to a higher temperature.

      Cause:

      Low water cut-out in the safety block has switched off (Service LED flashes 5 times).

      Remedy:

      Operator

      1. Ensure sufficient water supply.

      2. Check the device for leaks.

      Cause:

      Maximum temperature limiter in the water outlet (> 90 °C) has triggered.

      Remedy:

      Customer Service

      1. Check the temperature controller.

      Cause:

      Exhaust gas thermostat has triggered (service LED flashes 4 times)

      Remedy:

      Operator

      1. Set the power switch to "0".

      2. Allow the device to cool down.

      3. Switch the device on.

      Cause:

      Malfunction occurs repeatedly

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service menu indicator light (red) flashes 1x

      Cause:

      Direction of rotation is wrong.

      Remedy:

      Operator

      1. Swap the pins on the power plug.


      Service indicator light flashes 1x

      Cause:

      Leak in the high-pressure system.

      Remedy:

      Operator

      1. Check the high-pressure system and the connections for leaks.

      Service indicator light flashes 2x

      Cause:

      Fault in the voltage supply or current consumption of the motor too high.

      Remedy:

      Operator

      1. Check the power supply and the mains power supply circuit breaker.

      2. Contact Customer Service.

      Service indicator light flashes 3x

      Cause:

      Motor overloaded or overheated.

      Remedy:

      Operator

      1. Set the power switch to "0".

      2. Allow the device to cool down.

      3. Switch the device on.

      Cause:

      Malfunction occurs repeatedly.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service indicator light flashes 4x

      Cause:

      Exhaust gas thermostat has triggered.

      Remedy:

      Operator

      1. Set the power switch to "0".

      2. Allow the device to cool down.

      3. Switch the device on.

      Cause:

      Malfunction occurs repeatedly.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service indicator light flashes 5x

      Cause:

      Water shortage.

      Remedy:

      Operator

      1. Check the water connection and the supply lines.

      Cause:

      Reed switch stuck in the water shortage safeguard or magnetic piston stuck.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      The service indicator light flashes 6x

      Cause:

      Flame sensor has switched off the burner.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service indicator light flashes 7x

      Cause:

      Water outlet temperature sensor fault.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service indicator light flashes 8x

      Cause:

      Communication fault.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      System care LED lights up

      Cause:

      System care used up.

      Remedy:

      Operator

      1. Refill the system care.

      Pump not reaching the required pressure

      Cause:

      Flushed the nozzle.

      Remedy:

      Operator

      1. Replace the nozzle.

      Cause:

      Not enough water.

      Remedy:

      Operator

      1. Ensure for sufficient water supply.

      Cause:

      Water inlet filter dirty.

      Remedy:

      Operator

      1. Clean the filter.

      Cause:

      Fine filter dirty.

      Remedy:

      Operator

      1. Clean the filter.

      Cause:

      Float valve is jammed.

      Remedy:

      Operator

      1. Check the valve for free movement.

      Cause:

      Safety valve is leaky.

      Remedy:

      Customer Service

      1. Check the setting.

      2. Install new seal, if required.

      Cause:

      Flow control valve is leaking or set too low.

      Remedy:

      Customer Service

      1. Check the valve parts.

      2. Replace the parts if damaged, clean if dirty.

      Cause:

      Solenoid valve for pressure relief is defective.

      Remedy:

      Customer Service

      1. Replace the solenoid valve.

      High-pressure pump knocking

      Cause:

      Water pump draws in a small amount of air.

      Remedy:

      Customer Service department

      1. Check the suction system and eliminate any leaks.

      The device keeps turning on and off when the high-pressure gun is open.

      Cause:

      Nozzle in the spray lance is clogged.

      Remedy:

      Operator

      1. Check the nozzle and clean it.

      Cause:

      Device is scaled.

      Remedy:

      Customer Service

      1. Descale the device.

      Cause:

      The switching point of the overflow valve has become misaligned.

      Remedy:

      Customer Service

      1. Reset the overflow valve.

      The device does not switch off when the high-pressure gun is closed

      Cause:

      Air in the pump.

      Remedy:

      Operator

      1. Vent the device.

      Cause:

      Safety valve or safety valve seal is defective.

      Remedy:

      Customer Service

      1. Replace the safety valve or the seal.

      Cause:

      Pressure switch faulty.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Who is permitted to eliminate faults?

      Operator: Work labelled with "Operator" may only be performed by instructed persons capable of operating and maintaining high-pressure systems.

      Qualified electrician: Work labelled with "Electrician" may only be performed by qualified electricians.

      Customer Service: Work labelled with "Customer service" may only be performed by KÄRCHER customer service technicians or KÄRCHER-authorised technicians.

      • Burner does not ignite or flame goes out during operation 

      • Service menu indicator light (red) flashes 1x 

      • Service indicator light flashes 1x 

      • Service indicator light flashes 2x 

      • Service indicator light flashes 3x 

      • Service indicator light flashes 4x 

      • Service indicator light flashes 5x 

      • The service indicator light flashes 6x 

      • Service indicator light flashes 7x 

      • Service indicator light flashes 8x 

      • System care LED lights up 

      • Pump not reaching the required pressure 

      • High-pressure pump knocking 

      • The device keeps turning on and off when the high-pressure gun is open. 

      • The device does not switch off when the high-pressure gun is closed 

      Burner does not ignite or flame goes out during operation

      Cause:

      Temperature controller set too low.

      Remedy:

      Operator

      1. Set the temperature regulator higher.

      Cause:

      Power switch is not set to warm water.

      Remedy:

      Operator

      1. Set the device to a higher temperature.

      Cause:

      Low water cut-out in the safety block has switched off (Service LED flashes 5 times).

      Remedy:

      Operator

      1. Ensure sufficient water supply.

      2. Check the device for leaks.

      Cause:

      Maximum temperature limiter in the water outlet (> 90 °C) has triggered.

      Remedy:

      Customer Service

      1. Check the temperature controller.

      Cause:

      Exhaust gas thermostat has triggered (service LED flashes 4 times)

      Remedy:

      Operator

      1. Set the power switch to "0".

      2. Allow the device to cool down.

      3. Switch the device on.

      Cause:

      Malfunction occurs repeatedly

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service menu indicator light (red) flashes 1x

      Cause:

      Direction of rotation is wrong.

      Remedy:

      Operator

      1. Swap the pins on the power plug.


      Service indicator light flashes 1x

      Cause:

      Leak in the high-pressure system.

      Remedy:

      Operator

      1. Check the high-pressure system and the connections for leaks.

      Service indicator light flashes 2x

      Cause:

      Fault in the voltage supply or current consumption of the motor too high.

      Remedy:

      Operator

      1. Check the power supply and the mains power supply circuit breaker.

      2. Contact Customer Service.

      Service indicator light flashes 3x

      Cause:

      Motor overloaded or overheated.

      Remedy:

      Operator

      1. Set the power switch to "0".

      2. Allow the device to cool down.

      3. Switch the device on.

      Cause:

      Malfunction occurs repeatedly.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service indicator light flashes 4x

      Cause:

      Exhaust gas thermostat has triggered.

      Remedy:

      Operator

      1. Set the power switch to "0".

      2. Allow the device to cool down.

      3. Switch the device on.

      Cause:

      Malfunction occurs repeatedly.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service indicator light flashes 5x

      Cause:

      Water shortage.

      Remedy:

      Operator

      1. Check the water connection and the supply lines.

      Cause:

      Reed switch stuck in the water shortage safeguard or magnetic piston stuck.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      The service indicator light flashes 6x

      Cause:

      Flame sensor has switched off the burner.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service indicator light flashes 7x

      Cause:

      Water outlet temperature sensor fault.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service indicator light flashes 8x

      Cause:

      Communication fault.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      System care LED lights up

      Cause:

      System care used up.

      Remedy:

      Operator

      1. Refill the system care.

      Pump not reaching the required pressure

      Cause:

      Flushed the nozzle.

      Remedy:

      Operator

      1. Replace the nozzle.

      Cause:

      Not enough water.

      Remedy:

      Operator

      1. Ensure for sufficient water supply.

      Cause:

      Water inlet filter dirty.

      Remedy:

      Operator

      1. Clean the filter.

      Cause:

      Fine filter dirty.

      Remedy:

      Operator

      1. Clean the filter.

      Cause:

      Float valve is jammed.

      Remedy:

      Operator

      1. Check the valve for free movement.

      Cause:

      Safety valve is leaky.

      Remedy:

      Customer Service

      1. Check the setting.

      2. Install new seal, if required.

      Cause:

      Flow control valve is leaking or set too low.

      Remedy:

      Customer Service

      1. Check the valve parts.

      2. Replace the parts if damaged, clean if dirty.

      Cause:

      Solenoid valve for pressure relief is defective.

      Remedy:

      Customer Service

      1. Replace the solenoid valve.

      High-pressure pump knocking

      Cause:

      Water pump draws in a small amount of air.

      Remedy:

      Customer Service department

      1. Check the suction system and eliminate any leaks.

      The device keeps turning on and off when the high-pressure gun is open.

      Cause:

      Nozzle in the spray lance is clogged.

      Remedy:

      Operator

      1. Check the nozzle and clean it.

      Cause:

      Device is scaled.

      Remedy:

      Customer Service

      1. Descale the device.

      Cause:

      The switching point of the overflow valve has become misaligned.

      Remedy:

      Customer Service

      1. Reset the overflow valve.

      The device does not switch off when the high-pressure gun is closed

      Cause:

      Air in the pump.

      Remedy:

      Operator

      1. Vent the device.

      Cause:

      Safety valve or safety valve seal is defective.

      Remedy:

      Customer Service

      1. Replace the safety valve or the seal.

      Cause:

      Pressure switch faulty.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Troubleshooting

      • Burner does not ignite or flame goes out during operation 

      • Service menu indicator light (red) flashes 1x 

      • Service indicator light flashes 1x 

      • Service indicator light flashes 2x 

      • Service indicator light flashes 3x 

      • Service indicator light flashes 4x 

      • Service indicator light flashes 5x 

      • The service indicator light flashes 6x 

      • Service indicator light flashes 7x 

      • Service indicator light flashes 8x 

      • System care LED lights up 

      • Pump not reaching the required pressure 

      • High-pressure pump knocking 

      • The device keeps turning on and off when the high-pressure gun is open. 

      • The device does not switch off when the high-pressure gun is closed 

      Burner does not ignite or flame goes out during operation

      Cause:

      Temperature controller set too low.

      Remedy:

      Operator

      1. Set the temperature regulator higher.

      Cause:

      Power switch is not set to warm water.

      Remedy:

      Operator

      1. Set the device to a higher temperature.

      Cause:

      Low water cut-out in the safety block has switched off (Service LED flashes 5 times).

      Remedy:

      Operator

      1. Ensure sufficient water supply.

      2. Check the device for leaks.

      Cause:

      Maximum temperature limiter in the water outlet (> 90 °C) has triggered.

      Remedy:

      Customer Service

      1. Check the temperature controller.

      Cause:

      Exhaust gas thermostat has triggered (service LED flashes 4 times)

      Remedy:

      Operator

      1. Set the power switch to "0".

      2. Allow the device to cool down.

      3. Switch the device on.

      Cause:

      Malfunction occurs repeatedly

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service menu indicator light (red) flashes 1x

      Cause:

      Direction of rotation is wrong.

      Remedy:

      Operator

      1. Swap the pins on the power plug.


      Service indicator light flashes 1x

      Cause:

      Leak in the high-pressure system.

      Remedy:

      Operator

      1. Check the high-pressure system and the connections for leaks.

      Service indicator light flashes 2x

      Cause:

      Fault in the voltage supply or current consumption of the motor too high.

      Remedy:

      Operator

      1. Check the power supply and the mains power supply circuit breaker.

      2. Contact Customer Service.

      Service indicator light flashes 3x

      Cause:

      Motor overloaded or overheated.

      Remedy:

      Operator

      1. Set the power switch to "0".

      2. Allow the device to cool down.

      3. Switch the device on.

      Cause:

      Malfunction occurs repeatedly.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service indicator light flashes 4x

      Cause:

      Exhaust gas thermostat has triggered.

      Remedy:

      Operator

      1. Set the power switch to "0".

      2. Allow the device to cool down.

      3. Switch the device on.

      Cause:

      Malfunction occurs repeatedly.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service indicator light flashes 5x

      Cause:

      Water shortage.

      Remedy:

      Operator

      1. Check the water connection and the supply lines.

      Cause:

      Reed switch stuck in the water shortage safeguard or magnetic piston stuck.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      The service indicator light flashes 6x

      Cause:

      Flame sensor has switched off the burner.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service indicator light flashes 7x

      Cause:

      Water outlet temperature sensor fault.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service indicator light flashes 8x

      Cause:

      Communication fault.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      System care LED lights up

      Cause:

      System care used up.

      Remedy:

      Operator

      1. Refill the system care.

      Pump not reaching the required pressure

      Cause:

      Flushed the nozzle.

      Remedy:

      Operator

      1. Replace the nozzle.

      Cause:

      Not enough water.

      Remedy:

      Operator

      1. Ensure for sufficient water supply.

      Cause:

      Water inlet filter dirty.

      Remedy:

      Operator

      1. Clean the filter.

      Cause:

      Fine filter dirty.

      Remedy:

      Operator

      1. Clean the filter.

      Cause:

      Float valve is jammed.

      Remedy:

      Operator

      1. Check the valve for free movement.

      Cause:

      Safety valve is leaky.

      Remedy:

      Customer Service

      1. Check the setting.

      2. Install new seal, if required.

      Cause:

      Flow control valve is leaking or set too low.

      Remedy:

      Customer Service

      1. Check the valve parts.

      2. Replace the parts if damaged, clean if dirty.

      Cause:

      Solenoid valve for pressure relief is defective.

      Remedy:

      Customer Service

      1. Replace the solenoid valve.

      High-pressure pump knocking

      Cause:

      Water pump draws in a small amount of air.

      Remedy:

      Customer Service department

      1. Check the suction system and eliminate any leaks.

      The device keeps turning on and off when the high-pressure gun is open.

      Cause:

      Nozzle in the spray lance is clogged.

      Remedy:

      Operator

      1. Check the nozzle and clean it.

      Cause:

      Device is scaled.

      Remedy:

      Customer Service

      1. Descale the device.

      Cause:

      The switching point of the overflow valve has become misaligned.

      Remedy:

      Customer Service

      1. Reset the overflow valve.

      The device does not switch off when the high-pressure gun is closed

      Cause:

      Air in the pump.

      Remedy:

      Operator

      1. Vent the device.

      Cause:

      Safety valve or safety valve seal is defective.

      Remedy:

      Customer Service

      1. Replace the safety valve or the seal.

      Cause:

      Pressure switch faulty.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Customer Service department

      If the malfunction cannot be corrected, the device must be checked by the Customer Service department.

      • Burner does not ignite or flame goes out during operation 

      • Service menu indicator light (red) flashes 1x 

      • Service indicator light flashes 1x 

      • Service indicator light flashes 2x 

      • Service indicator light flashes 3x 

      • Service indicator light flashes 4x 

      • Service indicator light flashes 5x 

      • The service indicator light flashes 6x 

      • Service indicator light flashes 7x 

      • Service indicator light flashes 8x 

      • System care LED lights up 

      • Pump not reaching the required pressure 

      • High-pressure pump knocking 

      • The device keeps turning on and off when the high-pressure gun is open. 

      • The device does not switch off when the high-pressure gun is closed 

      Burner does not ignite or flame goes out during operation

      Cause:

      Temperature controller set too low.

      Remedy:

      Operator

      1. Set the temperature regulator higher.

      Cause:

      Power switch is not set to warm water.

      Remedy:

      Operator

      1. Set the device to a higher temperature.

      Cause:

      Low water cut-out in the safety block has switched off (Service LED flashes 5 times).

      Remedy:

      Operator

      1. Ensure sufficient water supply.

      2. Check the device for leaks.

      Cause:

      Maximum temperature limiter in the water outlet (> 90 °C) has triggered.

      Remedy:

      Customer Service

      1. Check the temperature controller.

      Cause:

      Exhaust gas thermostat has triggered (service LED flashes 4 times)

      Remedy:

      Operator

      1. Set the power switch to "0".

      2. Allow the device to cool down.

      3. Switch the device on.

      Cause:

      Malfunction occurs repeatedly

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service menu indicator light (red) flashes 1x

      Cause:

      Direction of rotation is wrong.

      Remedy:

      Operator

      1. Swap the pins on the power plug.


      Service indicator light flashes 1x

      Cause:

      Leak in the high-pressure system.

      Remedy:

      Operator

      1. Check the high-pressure system and the connections for leaks.

      Service indicator light flashes 2x

      Cause:

      Fault in the voltage supply or current consumption of the motor too high.

      Remedy:

      Operator

      1. Check the power supply and the mains power supply circuit breaker.

      2. Contact Customer Service.

      Service indicator light flashes 3x

      Cause:

      Motor overloaded or overheated.

      Remedy:

      Operator

      1. Set the power switch to "0".

      2. Allow the device to cool down.

      3. Switch the device on.

      Cause:

      Malfunction occurs repeatedly.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service indicator light flashes 4x

      Cause:

      Exhaust gas thermostat has triggered.

      Remedy:

      Operator

      1. Set the power switch to "0".

      2. Allow the device to cool down.

      3. Switch the device on.

      Cause:

      Malfunction occurs repeatedly.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service indicator light flashes 5x

      Cause:

      Water shortage.

      Remedy:

      Operator

      1. Check the water connection and the supply lines.

      Cause:

      Reed switch stuck in the water shortage safeguard or magnetic piston stuck.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      The service indicator light flashes 6x

      Cause:

      Flame sensor has switched off the burner.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service indicator light flashes 7x

      Cause:

      Water outlet temperature sensor fault.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Service indicator light flashes 8x

      Cause:

      Communication fault.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      System care LED lights up

      Cause:

      System care used up.

      Remedy:

      Operator

      1. Refill the system care.

      Pump not reaching the required pressure

      Cause:

      Flushed the nozzle.

      Remedy:

      Operator

      1. Replace the nozzle.

      Cause:

      Not enough water.

      Remedy:

      Operator

      1. Ensure for sufficient water supply.

      Cause:

      Water inlet filter dirty.

      Remedy:

      Operator

      1. Clean the filter.

      Cause:

      Fine filter dirty.

      Remedy:

      Operator

      1. Clean the filter.

      Cause:

      Float valve is jammed.

      Remedy:

      Operator

      1. Check the valve for free movement.

      Cause:

      Safety valve is leaky.

      Remedy:

      Customer Service

      1. Check the setting.

      2. Install new seal, if required.

      Cause:

      Flow control valve is leaking or set too low.

      Remedy:

      Customer Service

      1. Check the valve parts.

      2. Replace the parts if damaged, clean if dirty.

      Cause:

      Solenoid valve for pressure relief is defective.

      Remedy:

      Customer Service

      1. Replace the solenoid valve.

      High-pressure pump knocking

      Cause:

      Water pump draws in a small amount of air.

      Remedy:

      Customer Service department

      1. Check the suction system and eliminate any leaks.

      The device keeps turning on and off when the high-pressure gun is open.

      Cause:

      Nozzle in the spray lance is clogged.

      Remedy:

      Operator

      1. Check the nozzle and clean it.

      Cause:

      Device is scaled.

      Remedy:

      Customer Service

      1. Descale the device.

      Cause:

      The switching point of the overflow valve has become misaligned.

      Remedy:

      Customer Service

      1. Reset the overflow valve.

      The device does not switch off when the high-pressure gun is closed

      Cause:

      Air in the pump.

      Remedy:

      Operator

      1. Vent the device.

      Cause:

      Safety valve or safety valve seal is defective.

      Remedy:

      Customer Service

      1. Replace the safety valve or the seal.

      Cause:

      Pressure switch faulty.

      Remedy:

      Customer Service

      1. Contact Customer Service.

      Warranty

      The warranty conditions issued by our relevant sales company apply in all countries. We shall remedy possible malfunctions on your appliance within the warranty period free of cost, provided that a material or manufacturing flaw is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.

      Further information can be found at: www.kaercher.com/dealersearch

      Further warranty information (if available) can be found in the service area of your local Kärcher website under "Downloads".

      Accessories and spare parts

      Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.

      Information on accessories and spare parts can be found at www.kaercher.com.

      Declaration of Conformity

      EU Declaration of Conformity

      We hereby declare that the machine described below complies with the relevant basic safety and health requirements in the EU Directives, both in its basic design and construction as well as in the version placed in circulation by us. This declaration is invalidated by any changes made to the machine that are not approved by us.

      Product: High-pressure cleaner

      Type: 1.030-xxx

      Currently applicable EU Directives

      2000/14/EC

      2006/42/EC (+2009/127/EC)

      2009/125/EC

      2011/65/EU

      2014/30/EU

      Harmonised standards used

      EN IEC 63000: 2018

      EN 55014-1: 2017 + A11: 2020

      EN 55014-2: 1997 + A1: 2001 + A2: 2008

      EN 60335-1

      EN 60335-2-79

      EN 61000-3-2: 2014

      EN 61000-3-3: 2013

      EN 62233: 2008

      Commission Regulation(s)

      (EU) 2019/1781

      Conformity evaluation procedure used

      2000/14/EC: Annex V

      Sound power level dB(A)

      HDS Classic

      Measured: 97

      Guaranteed: 100

      National standards used

      -

      The signatories act on behalf of and with the authority of the company management.


      Documentation supervisor:

      S. Reiser

      Alfred Kärcher SE & Co. KG

      Alfred-Kärcher-Str. 28 - 40

      71364 Winnenden (Germany)

      Ph.: +49 7195 14-0

      Fax: +49 7195 14-2212

      Winnenden, 2022/10/01

      Declaration of Conformity (UK)

      We hereby declare that the product described below complies with the relevant provisions of the following UK Regulations, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the product is modified without our prior approval.

      Product: High-pressure cleaner

      Type: 1.030-xxx

      Currently applicable UK Regulations

      S.I. 2001/1701 (as amended)

      S.I. 2008/1597 (as amended)

      S.I. 2010/2617 (as amended)

      S.I. 2012/3032 (as amended)

      S.I. 2016/1091 (as amended)

      Designated standards used

      EN IEC 63000: 2018

      EN 55014-1: 2017 + A11: 2020

      EN 55014-2: 1997 + A1: 2001 + A2: 2008

      EN 60335-1

      EN 60335-2-79

      EN 61000-3-2: 2014

      EN 61000-3-3: 2013

      EN 62233: 2008

      Commission Regulation(s)

      (EU) 2019/1781

      Conformity assessment procedure used

      S.I. 2001/1701 (as amended): Schedule 8

      Sound power level dB(A)

      HDS Classic

      Measured: 97

      Guaranteed: 100

      National standards used

      -

      The signatories act on behalf of and with the authority of the company management.


      Documentation supervisor:

      S. Reiser

      Alfred Kärcher SE & Co. KG

      Alfred-Kärcher-Str. 28 - 40

      71364 Winnenden (Germany)

      Ph.: +49 7195 14-0

      Fax: +49 7195 14-2212

      Winnenden, 2022/10/01

      Technical data

        

      Electrical connection
      Mains voltage
      400 V
      Phase
      3 ~
      Power frequency
      50 Hz
      Degree of protection
      IPX5
      Protection class
      I
      Power rating
      11 kW
      Power protection (C-type, gL/gG)
      25 A
      Maximum permissible mains grid impedance
      (0.3007+j0.1879) Ω
      Water connection
      Feed pressure (max.)
      1 (10) MPa (bar)
      Input temperature (max.)
      30 °C
      Input amount (min.)
      2100 (35) l/h (l/min)
      Minimum water supply hose length
      7,5 m
      Minimum water supply hose diameter
      1 Inches
      Device performance data
      Water flow rate
      870-1730 (14,5-28,8) l/h (l/min)
      Water operating pressure with standard nozzle
      5-18,3 (50-183) MPa (bar)
      Excess operating pressure safety valve (maximum)
      23,5 (235) MPa (bar)
      Hot water operating temperature (maximum)
      93 °C
      Burner output
      108 kW
      Heating oil consumption (max.)
      6,5 kg/h
      High-pressure gun recoil force
      95 N
      Nozzle size of standard nozzle
      100
      Dimensions and weights
      Typical operating weight
      255 kg
      Length x width x height
      1320 x 770 x 920 mm
      Fuel tank
      30 l
      High-pressure pump
      Oil volume
      1,2 l
      Oil type
      15W40
      Burner
      Fuel
      EL heating oil or diesel
      Determined values in acc. with EN 60335-2-79
      Sound pressure level LpA
      82 dB(A)
      Uncertainty KpA
      3 dB(A)
      Sound power level LWA + uncertainty KWA
      100 dB(A)
      Hand-arm vibration value
      5,6 m/s2
      Uncertainty K
      2,1 m/s2
      <BackPage>

       

        

       