HDS 18/18-4 S Classic

59802380 (10/24)
59802380 (10/24)
Read these original instructions and the enclosed safety instructions before using the device for the first time. Act in accordance with them.
Keep both books for future reference or for future owners.
If the operating instructions and safety instructions are not observed, the device can be damaged and dangers could arise for users and other persons.
Notify the dealer immediately in the case of shipping damage.
Check the package contents when unpacking for missing accessories or for damage. Scope of delivery see illustration A.
At operating elevations of approx. 800 m above sea level or higher, please contact your dealer to have the burner setting adjusted to the elevation and reduced oxygen content.
The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.
Electrical and electronic devices contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which - if handled or disposed of incorrectly - can pose a potential danger to human health and the environment. However, these components are required for the correct operation of the device. Devices marked by this symbol are not allowed to be disposed of together with the household rubbish.
Current information on content materials can be found at: www.kaercher.de/REACH
Please do not allow engine oil, heating oil, diesel and petrol to enter the environment. Please protect the ground and dispose of old oil in an environmentally friendly manner.
0 = Off
![]() | Do not point the high-pressure jet at people, animals, live electrical equipment or at the device itself. Protect the device from frost. |
![]() | Danger of injury from electrical voltage. Only qualified electricians or authorised and qualified technical specialists are permitted to work on the electrical systems. |
![]() | According to applicable regulations, the device must never be used with the drinking water network without a system separator. Ensure that the connection to your house water system, with which the high-pressure cleaner is operated, is equipped with a system separator according to EN 12729 type BA. Water that has flowed through a system separator is classified as undrinkable. Always connect the system separator to the water supply and never directly to the device. |
![]() | Health risk from poisonous exhaust gases. Never inhale the exhaust gases. |
![]() | Risk of burns from hot surfaces. |
![]() | Code for information |
Only use the device for cleaning, e.g. machines, vehicles, buildings, tools, façades, terraces and garden equipment.
Use at petrol stations or other hazard zones
Risk of injury
Adhere to the respective safety regulations.Do not allow waste water containing mineral oil to penetrate soil, waterways or the sewage system. Only wash the motor or the undercarriage in suitable places with an oil separator.
Dirty water
Premature wear and tear or deposits in the device
Supply the device using only clean water, or recycled water that does not exceed the specified limit values.The following limit values apply to the water supply:
pH value: 6.5-9.5
Electrical conductivity: Conductivity of fresh water + 1200 µS/cm, maximum conductivity 2000 µS/cm
Settleable particles (sample volume 1 l, settling time 30 minutes): < 0.5 mg/l
Filterable particles: < 50 mg/l, no abrasive substances
Hydrocarbons: < 20 mg/l
Chloride: < 300 mg/l
Sulphate: < 240 mg/l
Calcium: < 200 mg/l
Total hardness: < 28 °dH, < 50° TH, < 500 ppm (mg CaCO3/l)
Iron: < 0.5 mg/l
Manganese: < 0.05 mg/l
Copper: < 2 mg/l
Active chloride: < 0.3 mg/l
Free of unpleasant odours
The following safety instructions apply to the device:
Observe the respectively applicable national regulations for liquid jet cleaners.
Observe the respectively applicable national accident prevention regulations. Liquid jet cleaners must be tested regularly and the results of the test recorded in writing.
Note that the heating system in the device is classified as a furnace. Furnaces must be inspected regularly according to the applicable national regulations.
No modifications may be made to the device or accessories.
To avoid hazards from excessive temperatures, you must set the pressure/quantity regulator of the pump unit to MAX at work temperatures above 60 °C.
Safety devices protect the user and may not be disabled or functionally circumvented.
When reducing the water volume at the pump head or with the pressure/quantity regulator on the high-pressure gun, the overflow valve opens and part of the water flows back to the pump suction side.
When the high-pressure gun is closed, the pressure relief valve opens and all the water flows back to the pump suction side. The pressure switch on the overflow valve sends a signal to the control unit, which switches the pump off after approx. 30 seconds of after-running time.
If the high-pressure gun is opened again, the pressure switch at the overflow valve switches the pump on again.
The overflow valve is set and sealed at the factory. The adjustment is performed only by customer service.
The safety valve opens if the system pressure is too high.
The safety valve is adjusted and sealed at the factory. The adjustment is performed only by customer service.
The water shortage safeguard prevents the burner from switching on when there is a lack of water.
The exhaust gas thermostat switches the device off when the emission temperature is too high.
The flame monitoring system monitors the brightness of the flame on the burner and switches the burner off in the event of a fault.
The device current is limited by the HDS control circuit board. In addition, the fan motor and the pump motor are each protected by a winding protection contact.
The temperature sensor switches the burner off when the set water temperature is reached.
The safety catch on the high-pressure gun prevents the device from being switched on inadvertently.
If the device is not used for 30 minutes, the device switches off. The readiness time can be activated and deactivated by customer service via the service menu.
Damaged components
Risk of injury
Check that the device, accessories, supply lines and connections are in perfect condition. If the condition is not perfect, you may not use the device.Apply the parking brake.
Milky oil
Device damage
If the oil is milky, inform authorized Customer Service immediately.Place the device on a flat and level surface.
Check the high-pressure pump oil level at the oil level display.
The oil level must be in the middle of the oil level indication.
Top up the oil if necessary.
The EASY!Lock system connects components quickly and safely via a single turn of the quick-release thread.
Connect the spray lance to the high-pressure gun and hand-tighten (EASY!Lock).
Plug the high-pressure nozzle onto the spray lance.
Fit the union nut and hand-tighten (EASY!Lock).
Connect the high-pressure hose to the high-pressure gun and high-pressure connection of the device and tighten hand-tight (EASY!Lock).
RM 110 prevents calcification of the heating coil in the presence of hard water.
RM 111 prevents the formation of black water and cares for the pump in the presence of soft water.
Water hardness (°dH) | System care products to be used |
<3 | RM 111 |
>3 | RM 110 |
Determine the local water hardness via the local supply company or with a hardness tester (order number 6.768-004.0).
The system care is not included in the scope of delivery.
The system care is a highly effective agent for preventing calcification of the heating coil when operating with calcareous tap water. This is drip-fed dosed into the float container.
The dosage is set to medium water hardness at the factory. The device can be adjusted to the local water hardness by customer service.
Refill the system care.
Unsuitable fuel
Risk of explosion
Only use diesel fuel or light heating oil. Unsuitable fuels, such as petrol, must not be used.Operation with an empty fuel tank
Destruction of the fuel pump
Never operate the device with an empty fuel tank.Open the tank cap.
Refill the fuel.
Close the tank cap.
Wipe up the spilt fuel.
See the "Technical data" for the connected loads.
The water supply hose is not included in the scope of delivery.
Connect the supply hose (minimum length 7.5 m, minimum diameter 1") to the water connection of the device and to the water supply (e.g. water tap).
Open the water inlet.
Unsuitable electrical extension cables
Electric shock
Only use approved and appropriately marked electrical extension cables with a sufficient line cross section for outdoors.Make sure that the plug and coupling of an extension cable used are watertight.Always unroll extension cables completely.Exceeding the grid impedance
Electrical shock in the event of a short-circuit
The maximum permissible mains grid impedance at the electrical connection point (see Technical data) must not be exceeded.Contact your electricity supplier in the case of any uncertainties regarding the mains grid impedance at your electrical connection point.For connected loads, see technical data and type plate.
The electrical connection must be carried out by an electrician and comply with IEC 60364-1.
Flammable fluids
Risk of explosion
Do not spray inflammable liquids.Operation without spray lance
Risk of injury
Never operate the device without the spray lance installed.Before each use, check that the spray lance is firmly seated. The screw connection of the spray lance must be tightened hand tight.High-pressure water jet
Danger of injury
Never fasten the trigger and safety lever in the actuated position.Do not use the high-pressure gun when the safety lever is damaged.Push the safety latch of the high-pressure gun forwards every time before starting work with the device.Hold the high-pressure gun and spray lance with both hands.Danger due to damaged mains cable
Electric shock
Make sure that the mains cable is not in contact with the burner (hot) during operation.Operation with an empty fuel tank
Destruction of the fuel pump
Never operate the device with an empty fuel tank.Opening the high-pressure gun: Actuate the safety lever and trigger.
Closing the high-pressure gun: Release the safety lever and trigger.
Switch off the device and operate the high-pressure gun until the device is depressurized.
Lock the high-pressure gun by pushing the safety latch forwards.
Change the nozzle.
Set the trigger to the operating mode. The standby mode indicator light lights up. The device starts up briefly and switches off as soon as the working pressure is reached.
If the direction of rotation indicator light lights up during operation, switch off the device immediately and rectify the fault, see "Troubleshooting".
Unlock the high-pressure gun by pushing the safety latch to the rear. When the high-pressure gun is actuated, the device switches on again.
If no water comes out of the high-pressure nozzle, bleed the pump. See help in the event of malfunctions – device does not build up pressure.
Turn the regulating spindle clockwise: Increase the working pressure (MAX).
Turn the regulating spindle anticlockwise: Reduce the working pressure (MIN).
Danger of a loose spray lance
Risk of injury
Take care to ensure that the spray lance screw connection does not release when adjusting the pressure/quantity control.If you want to work with reduced pressure over the long term, set the pressure on the pressure/quantity regulator of the pump unit.
Set the power switch to max. 90 °C.
Set the working pressure on the pressure/quantity regulator of the pump unit to the maximum value.
Adjust the working pressure and flow rate by turning (variable) the pressure/quantity regulator on the high-pressure gun (+/-).
Always initially direct the high-pressure jet at the object to be cleaned from a distance and with low temperature to avoid damage due to excessive pressure or temperature.
Set the cleaning temperature according to the surface to be cleaned.
For removing light contamination and for rinsing, e.g. garden machines, terrace, tools.
The device works in the most economical temperature range (max. 60 °C).
Hot water
Risk of scalding
Avoid contact with hot water.Danger due to excessive temperatures
Danger of scalding
To avoid hazards from excessive temperatures, you must set the pressure/quantity regulator of the pump unit to MAX at work temperatures above 60 °C.After operation with hot water, water droplets may occasionally escape from the safety valve due to the residual heat in the boiler.
Set the power switch to the desired temperature.
30-50 °C: Light soiling
Max. 60 °C: Soiling containing protein, e.g. in the food industry
60-90 °C: Car cleaning, machine cleaning
Lock the high-pressure gun by pushing the safety latch forwards.
Hot water hazard
Risk of scalding
After operation with hot water, the device must be operated with an opened gun with cold water for at least 2 minutes.Close the water inlet.
Open the high-pressure gun.
Switch on the pump with the power switch and let it run for 5-10 seconds.
Close the high-pressure gun.
Set the power switch to "0".
Only pull the mains plug out of the socket only when your hands are dry.
Remove the water connection.
Actuate the high-pressure gun until the device is completely depressurised.
Lock the high-pressure gun by pushing the safety latch forwards.
Do not kink the high-pressure hose or the electrical line.
Insert the high-pressure gun in the support on the frame together with the spray lance.
Roll up the high-pressure hose and the electrical line and hang them on the supports.
Frost hazard
Destruction of the device through freezing water
Store the device that has not been completely drained of water in a frost-free place.In the case of devices that are connected to a chimney, the ingress of cold air must be taken into account.
Cold air entering through the chimney
Risk of damage
When the exterior temperatures are below 0 °C, disconnect the device from the chimney.Shut down the device if frost-free storage is not possible.
For longer breaks in operation or when frost-free storage is not possible:
Drain the water.
Flush the device with antifreeze.
Unscrew the water supply hose and the high-pressure hose.
Unscrew the supply line at the boiler base and allow the heating coil to drain.
Allow the device for run for a maximum of 1 minute until the pump and lines are empty.
Observe the handling instructions of the anti-freeze manufacturer.
Pour a commercially available antifreeze into the float tank.
Switch on the device (without burner) and allow it to run until the device is completely flushed.
This also provides a certain degree of corrosion protection.
Improper transportation
Risk of damage
Protect the trigger of the high-pressure gun from damage.Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during transportation.Run a tensioning strap to secure the device between the wheel and the frame over the base plate. Observe the illustration.
When transporting the device in vehicles, secure it to prevent it from slipping or overturning in accordance with the respectively applicable guidelines.
Improper crane transport
Risk of injury from a falling device or falling objects
Observe the local regulations for accident prevention, laws and safety instructions.The device may only be transported with a crane by persons instructed in the operation of the crane.Check the lifting gear for damage before each crane transport.Check the strut on the device for damage before each crane transport.Lift the device only at the middle of the crane transport strut.Do not use slinging chains.Secure the lifting gear against unintentional unhooking of the load.Remove the spray lance with high-pressure gun and other loose objects before transporting by crane.Do not transport any objects on the device during the lifting operation.Do not stand under the suspended load.Ensure that no persons are in the hazard zones of the crane.Do not leave the device handing unattended on the crane.Fasten the lifting device to the struts for crane transport of the device.
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during storage.Inadvertently starting up device, touching live components
Risk of injury, electric shock
Switch off the device before performing any work on the device.Remove the mains plug.Close the water inlet.
Open the high-pressure gun.
Switch on the pump with the power switch and let it run for 5-10 seconds.
Close the high-pressure gun.
Set the power switch to "0".
Only pull the mains plug out of the socket only when your hands are dry.
Remove the water connection.
Actuate the high-pressure gun until the device is completely depressurised.
Lock the high-pressure gun by pushing the safety latch forwards.
Allow the device to cool down.
You can agree on regular safety inspections or close a maintenance contract with your dealer. Please seek advice on this.
Milky oil
Device damage
If the oil is milky, inform authorized Customer Service immediately.Clean the water inlet filter.
Clean the fine filter.
Clean the fuel strainer.
Clean the fuel filter.
Check the oil level.
Check the filling level of the system care container. Refill the system care if necessary.
Change the oil.
Have the device descaled by Customer Service.
Have the device maintained by Customer Service.
Depressurise the device.
Remove the union nut on the water inlet filter and take out the filter inlay.
Clean the filter inlay with clean water or compressed air.
Assemble in the reverse order.
Depressurise the device.
Unscrew the water hose on the fine filter.
Remove the union nut on the fine filter and take out the filter inlay.
Clean the filter inlay with clean water or compressed air.
Assemble in the reverse order.
Knock out the fuel sieve. Do not allow fuel to enter the environment.
Release the 3 fastening screws of the cover and remove the cover.
Remove the fuel filter.
Clean the fuel filter.
Remount the fuel filter.
See the "Technical data" section for the oil filling quantity and type.
Release the 3 fastening screws on the cover and remove the cover.
Release the 2 fastening screws between the fuel tank and the electrical box.
Lift the electrical box and push the fuel tank partially towards the burner fan. Support the electrical box on the motor.
Place a suitable catch pan for approx. 1.5 litres of oil under the pump.
Loosen the oil drain plug.
Drain the oil into the catch pan. Unscrew the oil filler plug completely so that the oil can drain off more quickly and completely.
Dispose of the old oil in an environmentally friendly manner or hand it over to an authorised collection point.
Retighten the oil drain plug, torque 20-25 Nm.
Slowly fill with new oil until the level is in the middle of the oil level display. The air bubbles must be able to escape.
Screw in the oil filler plug.
Push the fuel tank back into place.
Reinstall in the in the reverse order.
Inadvertently starting up device, touching live components
Risk of injury, electric shock
Switch off the device before performing any work on the device.Remove the mains plug.LED | Blink code | Meaning |
---|---|---|
Service menu LED (red) | - | Direction of rotation (wrong rotating field) |
Service LED (red) | lights up | Carry out service/maintenance |
flashes 1x | Leakage on the device | |
flashes 2x | Current/voltage fault:
| |
flashes 3x | Winding protection contact fault | |
flashes 4x | Exhaust gas fault | |
flashes 5x | Water shortage / dry running | |
flashes 6x | Flame sensor LED too bright / too dark | |
flashes 7x | Water outlet temperature sensor fault | |
flashes 8x | Communication fault | |
Operation LED (green) | lights up | Normal operation without faults |
flashes 1x | Pump has been running continuously for 30 minutes | |
flashes 2x | Pump has been continuously inactive for 30 minutes | |
System care LED (orange) | lights up | System care empty |
Burner does not ignite or flame goes out during operation
Cause:
Temperature controller set too low.
Remedy:
Operator
Set the temperature regulator higher.
Cause:
Power switch is not set to warm water.
Remedy:
Operator
Set the device to a higher temperature.
Cause:
Low water cut-out in the safety block has switched off (Service LED flashes 5 times).
Remedy:
Operator
Ensure sufficient water supply.
Check the device for leaks.
Cause:
Maximum temperature limiter in the water outlet (> 90 °C) has triggered.
Remedy:
Customer Service
Check the temperature controller.
Cause:
Exhaust gas thermostat has triggered (service LED flashes 4 times)
Remedy:
Operator
Set the power switch to "0".
Allow the device to cool down.
Switch the device on.
Cause:
Malfunction occurs repeatedly
Remedy:
Customer Service
Contact Customer Service.
Service menu indicator light (red) flashes 1x
Cause:
Direction of rotation is wrong.
Remedy:
Operator
Swap the pins on the power plug.
Service indicator light flashes 1x
Cause:
Leak in the high-pressure system.
Remedy:
Operator
Check the high-pressure system and the connections for leaks.
Service indicator light flashes 2x
Cause:
Fault in the voltage supply or current consumption of the motor too high.
Remedy:
Operator
Check the power supply and the mains power supply circuit breaker.
Contact Customer Service.
Service indicator light flashes 3x
Cause:
Motor overloaded or overheated.
Remedy:
Operator
Set the power switch to "0".
Allow the device to cool down.
Switch the device on.
Cause:
Malfunction occurs repeatedly.
Remedy:
Customer Service
Contact Customer Service.
Service indicator light flashes 4x
Cause:
Exhaust gas thermostat has triggered.
Remedy:
Operator
Set the power switch to "0".
Allow the device to cool down.
Switch the device on.
Cause:
Malfunction occurs repeatedly.
Remedy:
Customer Service
Contact Customer Service.
Service indicator light flashes 5x
Cause:
Water shortage.
Remedy:
Operator
Check the water connection and the supply lines.
Cause:
Reed switch stuck in the water shortage safeguard or magnetic piston stuck.
Remedy:
Customer Service
Contact Customer Service.
The service indicator light flashes 6x
Cause:
Flame sensor has switched off the burner.
Remedy:
Customer Service
Contact Customer Service.
Service indicator light flashes 7x
Cause:
Water outlet temperature sensor fault.
Remedy:
Customer Service
Contact Customer Service.
Service indicator light flashes 8x
Cause:
Communication fault.
Remedy:
Customer Service
Contact Customer Service.
System care LED lights up
Cause:
System care used up.
Remedy:
Operator
Refill the system care.
Cause:
Flushed the nozzle.
Remedy:
Operator
Replace the nozzle.
Cause:
Not enough water.
Remedy:
Operator
Ensure for sufficient water supply.
Cause:
Water inlet filter dirty.
Remedy:
Operator
Clean the filter.
Cause:
Fine filter dirty.
Remedy:
Operator
Clean the filter.
Cause:
Float valve is jammed.
Remedy:
Operator
Check the valve for free movement.
Cause:
Safety valve is leaky.
Remedy:
Customer Service
Check the setting.
Install new seal, if required.
Cause:
Flow control valve is leaking or set too low.
Remedy:
Customer Service
Check the valve parts.
Replace the parts if damaged, clean if dirty.
Cause:
Solenoid valve for pressure relief is defective.
Remedy:
Customer Service
Replace the solenoid valve.
Cause:
Water pump draws in a small amount of air.
Remedy:
Customer Service department
Check the suction system and eliminate any leaks.
Cause:
Nozzle in the spray lance is clogged.
Remedy:
Operator
Check the nozzle and clean it.
Cause:
Device is scaled.
Remedy:
Customer Service
Descale the device.
Cause:
The switching point of the overflow valve has become misaligned.
Remedy:
Customer Service
Reset the overflow valve.
Cause:
Air in the pump.
Remedy:
Operator
Vent the device.
Cause:
Safety valve or safety valve seal is defective.
Remedy:
Customer Service
Replace the safety valve or the seal.
Cause:
Pressure switch faulty.
Remedy:
Customer Service
Contact Customer Service.
Operator: Work labelled with "Operator" may only be performed by instructed persons capable of operating and maintaining high-pressure systems.
Qualified electrician: Work labelled with "Electrician" may only be performed by qualified electricians.
Customer Service: Work labelled with "Customer service" may only be performed by KÄRCHER customer service technicians or KÄRCHER-authorised technicians.
Burner does not ignite or flame goes out during operation
Cause:
Temperature controller set too low.
Remedy:
Operator
Set the temperature regulator higher.
Cause:
Power switch is not set to warm water.
Remedy:
Operator
Set the device to a higher temperature.
Cause:
Low water cut-out in the safety block has switched off (Service LED flashes 5 times).
Remedy:
Operator
Ensure sufficient water supply.
Check the device for leaks.
Cause:
Maximum temperature limiter in the water outlet (> 90 °C) has triggered.
Remedy:
Customer Service
Check the temperature controller.
Cause:
Exhaust gas thermostat has triggered (service LED flashes 4 times)
Remedy:
Operator
Set the power switch to "0".
Allow the device to cool down.
Switch the device on.
Cause:
Malfunction occurs repeatedly
Remedy:
Customer Service
Contact Customer Service.
Service menu indicator light (red) flashes 1x
Cause:
Direction of rotation is wrong.
Remedy:
Operator
Swap the pins on the power plug.
Service indicator light flashes 1x
Cause:
Leak in the high-pressure system.
Remedy:
Operator
Check the high-pressure system and the connections for leaks.
Service indicator light flashes 2x
Cause:
Fault in the voltage supply or current consumption of the motor too high.
Remedy:
Operator
Check the power supply and the mains power supply circuit breaker.
Contact Customer Service.
Service indicator light flashes 3x
Cause:
Motor overloaded or overheated.
Remedy:
Operator
Set the power switch to "0".
Allow the device to cool down.
Switch the device on.
Cause:
Malfunction occurs repeatedly.
Remedy:
Customer Service
Contact Customer Service.
Service indicator light flashes 4x
Cause:
Exhaust gas thermostat has triggered.
Remedy:
Operator
Set the power switch to "0".
Allow the device to cool down.
Switch the device on.
Cause:
Malfunction occurs repeatedly.
Remedy:
Customer Service
Contact Customer Service.
Service indicator light flashes 5x
Cause:
Water shortage.
Remedy:
Operator
Check the water connection and the supply lines.
Cause:
Reed switch stuck in the water shortage safeguard or magnetic piston stuck.
Remedy:
Customer Service
Contact Customer Service.
The service indicator light flashes 6x
Cause:
Flame sensor has switched off the burner.
Remedy:
Customer Service
Contact Customer Service.
Service indicator light flashes 7x
Cause:
Water outlet temperature sensor fault.
Remedy:
Customer Service
Contact Customer Service.
Service indicator light flashes 8x
Cause:
Communication fault.
Remedy:
Customer Service
Contact Customer Service.
System care LED lights up
Cause:
System care used up.
Remedy:
Operator
Refill the system care.
Cause:
Flushed the nozzle.
Remedy:
Operator
Replace the nozzle.
Cause:
Not enough water.
Remedy:
Operator
Ensure for sufficient water supply.
Cause:
Water inlet filter dirty.
Remedy:
Operator
Clean the filter.
Cause:
Fine filter dirty.
Remedy:
Operator
Clean the filter.
Cause:
Float valve is jammed.
Remedy:
Operator
Check the valve for free movement.
Cause:
Safety valve is leaky.
Remedy:
Customer Service
Check the setting.
Install new seal, if required.
Cause:
Flow control valve is leaking or set too low.
Remedy:
Customer Service
Check the valve parts.
Replace the parts if damaged, clean if dirty.
Cause:
Solenoid valve for pressure relief is defective.
Remedy:
Customer Service
Replace the solenoid valve.
Cause:
Water pump draws in a small amount of air.
Remedy:
Customer Service department
Check the suction system and eliminate any leaks.
Cause:
Nozzle in the spray lance is clogged.
Remedy:
Operator
Check the nozzle and clean it.
Cause:
Device is scaled.
Remedy:
Customer Service
Descale the device.
Cause:
The switching point of the overflow valve has become misaligned.
Remedy:
Customer Service
Reset the overflow valve.
Cause:
Air in the pump.
Remedy:
Operator
Vent the device.
Cause:
Safety valve or safety valve seal is defective.
Remedy:
Customer Service
Replace the safety valve or the seal.
Cause:
Pressure switch faulty.
Remedy:
Customer Service
Contact Customer Service.
Burner does not ignite or flame goes out during operation
Cause:
Temperature controller set too low.
Remedy:
Operator
Set the temperature regulator higher.
Cause:
Power switch is not set to warm water.
Remedy:
Operator
Set the device to a higher temperature.
Cause:
Low water cut-out in the safety block has switched off (Service LED flashes 5 times).
Remedy:
Operator
Ensure sufficient water supply.
Check the device for leaks.
Cause:
Maximum temperature limiter in the water outlet (> 90 °C) has triggered.
Remedy:
Customer Service
Check the temperature controller.
Cause:
Exhaust gas thermostat has triggered (service LED flashes 4 times)
Remedy:
Operator
Set the power switch to "0".
Allow the device to cool down.
Switch the device on.
Cause:
Malfunction occurs repeatedly
Remedy:
Customer Service
Contact Customer Service.
Service menu indicator light (red) flashes 1x
Cause:
Direction of rotation is wrong.
Remedy:
Operator
Swap the pins on the power plug.
Service indicator light flashes 1x
Cause:
Leak in the high-pressure system.
Remedy:
Operator
Check the high-pressure system and the connections for leaks.
Service indicator light flashes 2x
Cause:
Fault in the voltage supply or current consumption of the motor too high.
Remedy:
Operator
Check the power supply and the mains power supply circuit breaker.
Contact Customer Service.
Service indicator light flashes 3x
Cause:
Motor overloaded or overheated.
Remedy:
Operator
Set the power switch to "0".
Allow the device to cool down.
Switch the device on.
Cause:
Malfunction occurs repeatedly.
Remedy:
Customer Service
Contact Customer Service.
Service indicator light flashes 4x
Cause:
Exhaust gas thermostat has triggered.
Remedy:
Operator
Set the power switch to "0".
Allow the device to cool down.
Switch the device on.
Cause:
Malfunction occurs repeatedly.
Remedy:
Customer Service
Contact Customer Service.
Service indicator light flashes 5x
Cause:
Water shortage.
Remedy:
Operator
Check the water connection and the supply lines.
Cause:
Reed switch stuck in the water shortage safeguard or magnetic piston stuck.
Remedy:
Customer Service
Contact Customer Service.
The service indicator light flashes 6x
Cause:
Flame sensor has switched off the burner.
Remedy:
Customer Service
Contact Customer Service.
Service indicator light flashes 7x
Cause:
Water outlet temperature sensor fault.
Remedy:
Customer Service
Contact Customer Service.
Service indicator light flashes 8x
Cause:
Communication fault.
Remedy:
Customer Service
Contact Customer Service.
System care LED lights up
Cause:
System care used up.
Remedy:
Operator
Refill the system care.
Cause:
Flushed the nozzle.
Remedy:
Operator
Replace the nozzle.
Cause:
Not enough water.
Remedy:
Operator
Ensure for sufficient water supply.
Cause:
Water inlet filter dirty.
Remedy:
Operator
Clean the filter.
Cause:
Fine filter dirty.
Remedy:
Operator
Clean the filter.
Cause:
Float valve is jammed.
Remedy:
Operator
Check the valve for free movement.
Cause:
Safety valve is leaky.
Remedy:
Customer Service
Check the setting.
Install new seal, if required.
Cause:
Flow control valve is leaking or set too low.
Remedy:
Customer Service
Check the valve parts.
Replace the parts if damaged, clean if dirty.
Cause:
Solenoid valve for pressure relief is defective.
Remedy:
Customer Service
Replace the solenoid valve.
Cause:
Water pump draws in a small amount of air.
Remedy:
Customer Service department
Check the suction system and eliminate any leaks.
Cause:
Nozzle in the spray lance is clogged.
Remedy:
Operator
Check the nozzle and clean it.
Cause:
Device is scaled.
Remedy:
Customer Service
Descale the device.
Cause:
The switching point of the overflow valve has become misaligned.
Remedy:
Customer Service
Reset the overflow valve.
Cause:
Air in the pump.
Remedy:
Operator
Vent the device.
Cause:
Safety valve or safety valve seal is defective.
Remedy:
Customer Service
Replace the safety valve or the seal.
Cause:
Pressure switch faulty.
Remedy:
Customer Service
Contact Customer Service.
If the malfunction cannot be corrected, the device must be checked by the Customer Service department.
Burner does not ignite or flame goes out during operation
Cause:
Temperature controller set too low.
Remedy:
Operator
Set the temperature regulator higher.
Cause:
Power switch is not set to warm water.
Remedy:
Operator
Set the device to a higher temperature.
Cause:
Low water cut-out in the safety block has switched off (Service LED flashes 5 times).
Remedy:
Operator
Ensure sufficient water supply.
Check the device for leaks.
Cause:
Maximum temperature limiter in the water outlet (> 90 °C) has triggered.
Remedy:
Customer Service
Check the temperature controller.
Cause:
Exhaust gas thermostat has triggered (service LED flashes 4 times)
Remedy:
Operator
Set the power switch to "0".
Allow the device to cool down.
Switch the device on.
Cause:
Malfunction occurs repeatedly
Remedy:
Customer Service
Contact Customer Service.
Service menu indicator light (red) flashes 1x
Cause:
Direction of rotation is wrong.
Remedy:
Operator
Swap the pins on the power plug.
Service indicator light flashes 1x
Cause:
Leak in the high-pressure system.
Remedy:
Operator
Check the high-pressure system and the connections for leaks.
Service indicator light flashes 2x
Cause:
Fault in the voltage supply or current consumption of the motor too high.
Remedy:
Operator
Check the power supply and the mains power supply circuit breaker.
Contact Customer Service.
Service indicator light flashes 3x
Cause:
Motor overloaded or overheated.
Remedy:
Operator
Set the power switch to "0".
Allow the device to cool down.
Switch the device on.
Cause:
Malfunction occurs repeatedly.
Remedy:
Customer Service
Contact Customer Service.
Service indicator light flashes 4x
Cause:
Exhaust gas thermostat has triggered.
Remedy:
Operator
Set the power switch to "0".
Allow the device to cool down.
Switch the device on.
Cause:
Malfunction occurs repeatedly.
Remedy:
Customer Service
Contact Customer Service.
Service indicator light flashes 5x
Cause:
Water shortage.
Remedy:
Operator
Check the water connection and the supply lines.
Cause:
Reed switch stuck in the water shortage safeguard or magnetic piston stuck.
Remedy:
Customer Service
Contact Customer Service.
The service indicator light flashes 6x
Cause:
Flame sensor has switched off the burner.
Remedy:
Customer Service
Contact Customer Service.
Service indicator light flashes 7x
Cause:
Water outlet temperature sensor fault.
Remedy:
Customer Service
Contact Customer Service.
Service indicator light flashes 8x
Cause:
Communication fault.
Remedy:
Customer Service
Contact Customer Service.
System care LED lights up
Cause:
System care used up.
Remedy:
Operator
Refill the system care.
Cause:
Flushed the nozzle.
Remedy:
Operator
Replace the nozzle.
Cause:
Not enough water.
Remedy:
Operator
Ensure for sufficient water supply.
Cause:
Water inlet filter dirty.
Remedy:
Operator
Clean the filter.
Cause:
Fine filter dirty.
Remedy:
Operator
Clean the filter.
Cause:
Float valve is jammed.
Remedy:
Operator
Check the valve for free movement.
Cause:
Safety valve is leaky.
Remedy:
Customer Service
Check the setting.
Install new seal, if required.
Cause:
Flow control valve is leaking or set too low.
Remedy:
Customer Service
Check the valve parts.
Replace the parts if damaged, clean if dirty.
Cause:
Solenoid valve for pressure relief is defective.
Remedy:
Customer Service
Replace the solenoid valve.
Cause:
Water pump draws in a small amount of air.
Remedy:
Customer Service department
Check the suction system and eliminate any leaks.
Cause:
Nozzle in the spray lance is clogged.
Remedy:
Operator
Check the nozzle and clean it.
Cause:
Device is scaled.
Remedy:
Customer Service
Descale the device.
Cause:
The switching point of the overflow valve has become misaligned.
Remedy:
Customer Service
Reset the overflow valve.
Cause:
Air in the pump.
Remedy:
Operator
Vent the device.
Cause:
Safety valve or safety valve seal is defective.
Remedy:
Customer Service
Replace the safety valve or the seal.
Cause:
Pressure switch faulty.
Remedy:
Customer Service
Contact Customer Service.
The warranty conditions issued by our relevant sales company apply in all countries. We shall remedy possible malfunctions on your appliance within the warranty period free of cost, provided that a material or manufacturing flaw is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.
Further information can be found at: www.kaercher.com/dealersearch
Further warranty information (if available) can be found in the service area of your local Kärcher website under "Downloads".
Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.
Information on accessories and spare parts can be found at www.kaercher.com.
EU Declaration of Conformity |
We hereby declare that the machine described below complies with the relevant basic safety and health requirements in the EU Directives, both in its basic design and construction as well as in the version placed in circulation by us. This declaration is invalidated by any changes made to the machine that are not approved by us.
Product: High-pressure cleaner
Type: 1.030-xxx
Currently applicable EU Directives2000/14/EC
2006/42/EC (+2009/127/EC)
2009/125/EC
2011/65/EU
2014/30/EU
Harmonised standards usedEN IEC 63000: 2018
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 1997 + A1: 2001 + A2: 2008
EN 60335-1
EN 60335-2-79
EN 61000-3-2: 2014
EN 61000-3-3: 2013
EN 62233: 2008
Commission Regulation(s)(EU) 2019/1781
Conformity evaluation procedure used2000/14/EC: Annex V
Sound power level dB(A)HDS Classic
Measured: 97
Guaranteed: 100
National standards used-
The signatories act on behalf of and with the authority of the company management.
Documentation supervisor:
S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2022/10/01
Declaration of Conformity (UK) |
We hereby declare that the product described below complies with the relevant provisions of the following UK Regulations, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the product is modified without our prior approval.
Product: High-pressure cleaner
Type: 1.030-xxx
Currently applicable UK RegulationsS.I. 2001/1701 (as amended)
S.I. 2008/1597 (as amended)
S.I. 2010/2617 (as amended)
S.I. 2012/3032 (as amended)
S.I. 2016/1091 (as amended)
Designated standards usedEN IEC 63000: 2018
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 1997 + A1: 2001 + A2: 2008
EN 60335-1
EN 60335-2-79
EN 61000-3-2: 2014
EN 61000-3-3: 2013
EN 62233: 2008
Commission Regulation(s)(EU) 2019/1781
Conformity assessment procedure usedS.I. 2001/1701 (as amended): Schedule 8
Sound power level dB(A)HDS Classic
Measured: 97
Guaranteed: 100
National standards used-
The signatories act on behalf of and with the authority of the company management.
Documentation supervisor:
S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2022/10/01
Electrical connection | |
Mains voltage | 400 V |
Phase | 3 ~ |
Power frequency | 50 Hz |
Degree of protection | IPX5 |
Protection class | I |
Power rating | 11 kW |
Power protection (C-type, gL/gG) | 25 A |
Maximum permissible mains grid impedance | (0.3007+j0.1879) Ω |
Water connection | |
Feed pressure (max.) | 1 (10) MPa (bar) |
Input temperature (max.) | 30 °C |
Input amount (min.) | 2100 (35) l/h (l/min) |
Minimum water supply hose length | 7,5 m |
Minimum water supply hose diameter | 1 Inches |
Device performance data | |
Water flow rate | 870-1730 (14,5-28,8) l/h (l/min) |
Water operating pressure with standard nozzle | 5-18,3 (50-183) MPa (bar) |
Excess operating pressure safety valve (maximum) | 23,5 (235) MPa (bar) |
Hot water operating temperature (maximum) | 93 °C |
Burner output | 108 kW |
Heating oil consumption (max.) | 6,5 kg/h |
High-pressure gun recoil force | 95 N |
Nozzle size of standard nozzle | 100 |
Dimensions and weights | |
Typical operating weight | 255 kg |
Length x width x height | 1320 x 770 x 920 mm |
Fuel tank | 30 l |
High-pressure pump | |
Oil volume | 1,2 l |
Oil type | 15W40 |
Burner | |
Fuel | EL heating oil or diesel |
Determined values in acc. with EN 60335-2-79 | |
Sound pressure level LpA | 82 dB(A) |
Uncertainty KpA | 3 dB(A) |
Sound power level LWA + uncertainty KWA | 100 dB(A) |
Hand-arm vibration value | 5,6 m/s2 |
Uncertainty K | 2,1 m/s2 |