LogoT 11/1 ClassicT 11/1 Classic Re!PlastT 11/1 Classic Adv Re!PlastT 11/1 Classic HEPAT 11/1 Classic HEPA Re!Plast
  • General notes
  • Environmental protection
  • Intended use
  • Description of the device
  • Preparation
  • Initial startup
    • Operating modes
    • Installing the filter bag
  • Operation
    • Switching on the device
    • Cleaning mode
    • Switching off the device
    • Each time after use
  • Transport
  • Storage
  • Care and service
    • Cleaning the main filter basket
    • Replacing the motor protection filter
    • Replacing the HEPA filter
    • Replacing the mains cable
  • Troubleshooting guide
    • The device stops during operation

    • Suction turbine does not start up

    • Suction power decreases

    • Escaping dust when vacuuming

  • Customer Service department
    • The device stops during operation

    • Suction turbine does not start up

    • Suction power decreases

    • Escaping dust when vacuuming

  • Warranty
  • Accessories and spare parts
    • Attachment kit
  • Declaration of Conformity
  • Technical data
    • Kärcher T 11/1 Classic/Re!Plast
    • Kärcher T 11/1 Classic Adv Re!Plast
    • Kärcher T 11/1 Classic HEPA/Re!Plast

      T 11/1 Classic
      T 11/1 Classic Re!Plast
      T 11/1 Classic Adv Re!Plast
      T 11/1 Classic HEPA
      T 11/1 Classic HEPA Re!Plast

      59802580 (03/25)

      General notes

      Read these original instructions and the enclosed safety instructions before using the device for the first time. Act in accordance with them.

      Keep both books for future reference or for future owners.

      • If the operating instructions and safety instructions are not observed, the device can be damaged and dangers could arise for users and other persons.

      • Notify the dealer immediately in the case of shipping damage.

      • Check the package contents when unpacking for missing accessories or for damage.

      Environmental protection

      The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.

      Electrical and electronic devices contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which - if handled or disposed of incorrectly - can pose a potential danger to human health and the environment. However, these components are required for the correct operation of the device. Devices marked by this symbol are not allowed to be disposed of together with the household rubbish.

      Notes on the content materials (REACH)

      Current information on content materials can be found at: www.kaercher.de/REACH

      Intended use

      WARNING

      Health risk

      Inhalation of dusts that are harmful to health

      Do not use the device for vacuuming up dusts that are harmful to health.

      ATTENTION

      Damage to the device

      Short-circuit due to high levels of humidity

      Only use and store the device indoors.
      • This universal vacuum cleaner for carpets is intended for dry cleaning floor and wall surfaces.

      • This device is suitable for commercial use, e.g. in hotels, schools, hospitals, factories, shops, offices, and rental companies.

      Description of the device


      1. Fleece filter bag
      2. Suction hose port
      3. Suction hose
      4. Type plate
      5. Mount for accessories
      6. Carrying handle
      7. Hose holder
      8. Cable clips
      9. Mains cable
      10. Suction head
      11. Suction head lock
      12. Recessed grip
      13. Steering roller
      14. Dirt receptacle
      15. Mount for floor nozzle
      16. Main switch
      17. Hard surface/carpet switch
      18. Floor nozzle
      19. Suction pipe
      20. Main filter basket (T 11/1 Classic HEPA)
      21. Angle piece
      22. Main filter basket (T 11/1 Classic)
      23. Adapter plate (only T 11/1 Classic HEPA)
      24. HEPA filter (T 11/1 Classic HEPA only)
      25. Motor protection filter

      Preparation

      1. Unpack the device and install the accessories.


      Initial startup

      1. Check if the main filter basket is inserted in the device.

      Operating modes

      1. Operation with the filter bag

      2. Operation without the filter bag

      Installing the filter bag

      1. Unlock and remove the suction head.

      2. Remove the main filter basket.

      3. Fit the fleece filter bag.

      4. Insert the main filter basket.

      5. Fit and lock the suction head.

      Operation

      Switching on the device

      1. Connect the mains plug.

      2. Switch on the device at the main switch.

      Cleaning mode

      1. Set the floor nozzle switch to hard surface or carpet.

      2. Perform cleaning.

      Switching off the device

      1. Switch off the device at the main switch.

      2. Pull out the mains plug.

      Each time after use

      1. Empty the container.

      2. Vacuum off the inside and outside of the device and clean with a moist cloth.

      Transport

      CAUTION

      Failure to observe the weight

      Risk of injury and damage

      Be aware of the weight of the device during transportation.
      1. When transporting the device in vehicles, secure it to prevent it from slipping or overturning in accordance with the respective valid guidelines.

      Storage

      CAUTION

      Failure to observe the weight

      Risk of injury and damage

      Be aware of the weight of the device during storage.

      The device may only be operated indoors.

      Care and service

      DANGER

      Danger of electric shock

      Injuries due to touching live parts

      Switch off the device.Remove the mains plug.

      Cleaning the main filter basket

      ATTENTION

      Danger from wet main filter basket

      Risk of damage to the device

      Never insert the main filter basket when wet.
      1. If necessary, clean the main filter basket (washable) under running water.

      Replacing the motor protection filter

      T 11/1 Classic only:

      1. Unlock and remove the suction head.

      2. Remove the motor protection filter.

      3. Fit the new motor protection filter.

      4. Fit and lock the suction head.

      Replacing the HEPA filter

      T 11/1 Classic HEPA only:

      1. Unlock and remove the suction head.

      2. Turn the HEPA filter anticlockwise and remove it.

      3. Place the new HEPA filter on the adapter plate and tighten it clockwise as far as it will go.

      4. Fit and lock the suction head.

      Replacing the mains cable

      Only T 11/1 Classic Adv Re!Plast:

      1. Replace the mains cable.



      Troubleshooting guide

      DANGER

      Danger of electric shock

      Injuries due to touching live parts

      Switch off the device.Remove the mains plug.
      • The device stops during operation 

      • Suction turbine does not start up 

      • Suction power decreases 

      • Escaping dust when vacuuming 

      The device stops during operation

      Cause:

      The motor thermo-protector has triggered

      Remedy:

      1. Changing the fleece filter bag.

      2. T 11/1 Classic only: Replace the motor protection filter.

      3. T 11/1 Classic HEPA only: Replace the HEPA filter.

      4. Check all parts for clogging.

      5. Allow the engine turbine to cool for approx. 30-40 minutes. Switch on the device.

      Suction turbine does not start up

      Remedy:

      1. Check the socket and the power supply fuse.

      2. Check the mains cable and the mains plug of the device.

      3. Switch on the device.

      Suction power decreases

      Remedy:

      1. Remove any blockages from the suction nozzle, suction pipe or suction hose.

      2. Changing the fleece filter bag.

      3. Clean the main filter basket under running water and dry.

      4. Position/lock the suction head correctly.

      5. Replace the defective suction hose.

      6. T 11/1 Classic only: Replace the motor protection filter.

      7. T 11/1 Classic HEPA only: Replace the HEPA filter.

      Escaping dust when vacuuming

      Remedy:

      1. Changing the fleece filter bag.

      2. Check the fit of the fleece filter bag.

      3. Position/lock the suction head correctly.

      4. Insert the undamaged main filter basket.

      5. Insert the motor protection filter correctly.

      6. T 11/1 Classic HEPA only: Fasten the HEPA filter correctly.

      Customer Service department

      If the malfunction cannot be corrected, the device must be checked by the Customer Service department.

      • The device stops during operation 

      • Suction turbine does not start up 

      • Suction power decreases 

      • Escaping dust when vacuuming 

      The device stops during operation

      Cause:

      The motor thermo-protector has triggered

      Remedy:

      1. Changing the fleece filter bag.

      2. T 11/1 Classic only: Replace the motor protection filter.

      3. T 11/1 Classic HEPA only: Replace the HEPA filter.

      4. Check all parts for clogging.

      5. Allow the engine turbine to cool for approx. 30-40 minutes. Switch on the device.

      Suction turbine does not start up

      Remedy:

      1. Check the socket and the power supply fuse.

      2. Check the mains cable and the mains plug of the device.

      3. Switch on the device.

      Suction power decreases

      Remedy:

      1. Remove any blockages from the suction nozzle, suction pipe or suction hose.

      2. Changing the fleece filter bag.

      3. Clean the main filter basket under running water and dry.

      4. Position/lock the suction head correctly.

      5. Replace the defective suction hose.

      6. T 11/1 Classic only: Replace the motor protection filter.

      7. T 11/1 Classic HEPA only: Replace the HEPA filter.

      Escaping dust when vacuuming

      Remedy:

      1. Changing the fleece filter bag.

      2. Check the fit of the fleece filter bag.

      3. Position/lock the suction head correctly.

      4. Insert the undamaged main filter basket.

      5. Insert the motor protection filter correctly.

      6. T 11/1 Classic HEPA only: Fasten the HEPA filter correctly.

      Warranty

      The warranty conditions issued by our relevant sales company apply in all countries. We shall remedy possible malfunctions on your appliance within the warranty period free of cost, provided that a material or manufacturing flaw is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.

      Further information can be found at: www.kaercher.com/dealersearch

      Further warranty information (if available) can be found in the service area of your local Kärcher website under "Downloads".

      Accessories and spare parts

      Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.

      Information on accessories and spare parts can be found at www.kaercher.com.

      Attachment kit

      Description
      Order number
      HEPA filter attachment kit for T 11/1 Classic
      2.889-310.0

      Note

      After the HEPA filter has been installed, the instructions for the T 11/1 Classic HEPA in the operating instructions apply.

      Declaration of Conformity

      EU Declaration of Conformity

      We hereby declare that the machine described below complies with the relevant basic safety and health requirements in the EU Directives, both in its basic design and construction as well as in the version placed in circulation by us. This declaration is invalidated by any changes made to the machine that are not approved by us.

      Product: Dry vacuum cleaner

      Type: 1.527-xxx

      Currently applicable EU Directives

      2006/42/EC (+2009/127/EC)

      2009/125/EC

      2011/65/EU

      2014/30/EU

      Harmonised standards used

      EN IEC 63000: 2018

      EN 55014-1: 2017 + A11: 2020

      EN 55014-2: 2015

      EN 60312-1: 2017

      EN 60335-1

      EN 60335-2-69

      EN 61000-3-2: 2014

      EN 61000-3-3: 2013

      EN 62233: 2008

      National standards used

      -

      Commission Regulation(s)

      666/2013

      The signatories act on behalf of and with the authority of the company management.


      Documentation supervisor:

      S. Reiser

      Alfred Kärcher SE & Co. KG

      Alfred-Kärcher-Str. 28 - 40

      71364 Winnenden (Germany)

      Ph.: +49 7195 14-0

      Fax: +49 7195 14-2212

      Winnenden, 2020/10/01

      Declaration of Conformity (UK)

      We hereby declare that the product described below complies with the relevant provisions of the following UK Regulations, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the product is modified without our prior approval.

      Product: Dry vacuum cleaner

      Type: 1.527-xxx

      Currently applicable UK Regulations

      S.I. 2008/1597 (as amended)

      S.I. 2010/2617 (as amended)

      S.I. 2012/3032 (as amended)

      S.I. 2016/1091 (as amended)

      Designated standards used

      EN IEC 63000: 2018

      EN 55014-1: 2017 + A11: 2020

      EN 55014-2: 2015

      EN 60312-1: 2017

      EN 60335-1

      EN 60335-2-69

      EN 61000-3-2: 2014

      EN 61000-3-3: 2013

      EN 62233: 2008

      National standards used

      -

      Commission Regulation(s)

      (EU) No 666/2013

      The signatories act on behalf of and with the authority of the company management.


      Documentation supervisor:

      S. Reiser

      Alfred Kärcher SE & Co. KG

      Alfred-Kärcher-Str. 28 - 40

      71364 Winnenden (Germany)

      Ph.: +49 7195 14-0

      Fax: +49 7195 14-2212

      Winnenden, 2020/10/01

      Technical data

      • Kärcher T 11/1 Classic/Re!Plast 

      • Kärcher T 11/1 Classic Adv Re!Plast 

      • Kärcher T 11/1 Classic HEPA/Re!Plast 

      Kärcher T 11/1 Classic/Re!Plast

      Electrical connection
      Mains voltage
      220-240 V
      Phase
      1 ~
      Power frequency
      50-60 Hz
      Protection class
      II
      Rated power input
      850 W
      Device performance data
      Tank content
      11 l
      Air quantity (max.)
      40 l/s
      Vacuum (max.)
      23,5 (235) kPa (mbar)
      Dimensions and weights
      Length x width x height
      375 x 285 x 385 mm
      Typical operating weight
      3,8 kg
      Diameter of the suction hose
      35 mm
      Ambient conditions
      Ambient temperature (max.)
      +40 °C
      Determined values in acc. with EN 60335-2-69
      Sound level LpA
      61 dB(A)
      Uncertainty KpA
      2 dB(A)
      Sound power level LwA
      74 dB(A)
      Hand-arm vibration value
      <2,5 m/s2
      Uncertainty K
      0,2 m/s2
      Mains cable
      Power cord type
      H05VV-F 2x0,75 mm2
      Part number (EU)
      6.650-621.0
      Part number (GB)
      6.650-649.0
      Part number (CH)
      6.650-837.0
      Cable length
      7,5 m

      Kärcher T 11/1 Classic Adv Re!Plast

      Electrical connection
      Mains voltage
      220-240 V
      Phase
      1 ~
      Power frequency
      50-60 Hz
      Protection class
      II
      Rated power input
      850 W
      Device performance data
      Tank content
      11 l
      Air quantity (max.)
      40 l/s
      Vacuum (max.)
      23,5 (235) kPa (mbar)
      Dimensions and weights
      Length x width x height
      375 x 285 x 385 mm
      Typical operating weight
      4,2 kg
      Diameter of the suction hose
      35 mm
      Ambient conditions
      Ambient temperature (max.)
      +40 °C
      Determined values in acc. with EN 60335-2-69
      Sound level LpA
      61 dB(A)
      Uncertainty KpA
      2 dB(A)
      Sound power level LwA
      74 dB(A)
      Hand-arm vibration value
      <2,5 m/s2
      Uncertainty K
      0,2 m/s2
      Mains cable
      Power cord type
      H05VV-F 2x1,0 mm2
      Part number (EU)
      6.650-622.0
      Part number (CH)
      6.650-650.0
      Cable length
      12 m

      Kärcher T 11/1 Classic HEPA/Re!Plast

      Electrical connection
      Mains voltage
      220-240 V
      Phase
      1 ~
      Power frequency
      50-60 Hz
      Protection class
      II
      Rated power input
      850 W
      Device performance data
      Tank content
      11 l
      Air quantity (max.)
      40 l/s
      Vacuum (max.)
      23,5 (235) kPa (mbar)
      Dimensions and weights
      Length x width x height
      375 x 285 x 385 mm
      Typical operating weight
      4,2 kg
      Diameter of the suction hose
      35 mm
      Ambient conditions
      Ambient temperature (max.)
      +40 °C
      Determined values in acc. with EN 60335-2-69
      Sound level LpA
      61 dB(A)
      Uncertainty KpA
      2 dB(A)
      Sound power level LwA
      74 dB(A)
      Hand-arm vibration value
      <2,5 m/s2
      Uncertainty K
      0,2 m/s2
      Mains cable
      Power cord type
      H05VV-F 2x0,75 mm2
      Part number (EU)
      6.650-621.0
      Part number (GB)
      6.650-649.0
      Part number (CH)
      6.650-837.0
      Cable length
      7,5 m