LogoNT 65/2 Ap
  • General notes
  • Environmental protection
  • Intended use
  • Description of the device
    • Colour coding
  • Preparation
  • Initial startup
    • Dry vacuuming
      • Installing the paper filter bag
    • Wet vacuum cleaning
      • Installing the squeegees
      • Removing the paper filter bag
      • Draining the waste water
      • General
    • Clip connection
  • Operation
    • Switching on the device
    • Semi-automatic filter dedusting
    • Switching off the device
    • Each time after use
    • Storing the device
  • Transport
  • Storage
  • Care and service
    • Replacing the flat fold filter
    • Cleaning the electrodes
  • Troubleshooting guide
    • Suction turbine does not start up

    • Suction turbine switches off

    • Suction turbine does not switch on again after emptying the container

    • Suction power decreases

    • Escaping dust when vacuuming

    • The automatic switch-off mechanism (wet vacuum cleaning) does not trigger

    • Semi-automatic filter dedusting not working

    • Semi-automatic filter dedusting does not switch off

    • Semi-automatic filter dedusting cannot be switched on

  • Customer Service department
    • Suction turbine does not start up

    • Suction turbine switches off

    • Suction turbine does not switch on again after emptying the container

    • Suction power decreases

    • Escaping dust when vacuuming

    • The automatic switch-off mechanism (wet vacuum cleaning) does not trigger

    • Semi-automatic filter dedusting not working

    • Semi-automatic filter dedusting does not switch off

    • Semi-automatic filter dedusting cannot be switched on

  • Warranty
  • Accessories and spare parts
  • Technical data

      NT 65/2 Ap

      59991460 (05/24)

      General notes

      Read these original instructions and the enclosed safety instructions before using the device for the first time. Act in accordance with them.

      Keep both books for future reference or for future owners.

      • If the operating instructions and safety instructions are not observed, the device can be damaged and dangers could arise for users and other persons.

      • Notify the dealer immediately in the case of shipping damage.

      • Check the package contents when unpacking for missing accessories or for damage.

      Environmental protection

      The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.

      Electrical and electronic devices contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which - if handled or disposed of incorrectly - can pose a potential danger to human health and the environment. However, these components are required for the correct operation of the device. Devices marked by this symbol are not allowed to be disposed of together with the household rubbish.

      Notes on the content materials (REACH)

      Current information on content materials can be found at: www.kaercher.de/REACH

      Intended use

      WARNING

      Health risk

      Inhalation of dusts that are harmful to health

      Do not use the device for vacuuming up dusts that are harmful to health.
      • This vacuum cleaner is intended for the wet and dry cleaning of floor and wall surfaces.

      • This device is suitable for commercial use, e.g. in hotels, schools, hospitals, factories, shops, offices, and rental companies.

      Description of the device


      1. Electrodes
      2. Suction hose
      3. Push handle
      4. Suction head lock
      5. Dirt receptacle
      6. Suction head
      7. Steering roller
      8. Suction hose port
      9. Steering roller bracket
      10. Floor nozzle
      11. Suction pipe
      12. Turn switch
      13. Carrying handle
      14. Filter cover
      15. Filter dedusting button
      16. Hose holder
      17. Angle piece
      18. Drain hose
      19. Rest for floor nozzle
      20. Suction pipe holder
      21. Mains cable
      22. Holder for crevice nozzle
      23. Cable clips
      24. Type plate
      25. Filter dedusting
      26. Flat fold filter

      Colour coding

      • Control elements for the cleaning process are yellow.

      • Control elements for maintenance and servicing are light grey.

      Preparation

      1. Unpack the device and install the accessories.


      Initial startup

      ATTENTION

      Danger due to fine dust entering

      Risk of damage to the suction motor.

      Never remove the flat fold filter when vacuuming.

      Dry vacuuming

      • An additional paper filter bag can be used when vacuuming fine dust.

      Installing the paper filter bag

      1. Unlock and remove the suction head.

      2. Connect the paper filter bag.


      3. Fit and lock the suction head.

      Wet vacuum cleaning

      Note

      The flat fold filter (cellulose) with the order number 6.904-283.0 included in the scope of delivery is not recommended for regular wet vacuum cleaning.

      Installing the squeegees

      1. Remove the brush strip.


      2. Install the squeegees.

      Removing the paper filter bag

      • The paper filter bag must always be removed when vacuuming wet substances.

      • It is recommended to use a special filter bag (wet) (see filter systems).

      Draining the waste water

      WARNING

      Improper disposal of waste water

      Environmental pollution

      Observe the local waste water treatment regulations.
      1. Drain the waste water via the drain hose.


      General

      • We recommend not using the "Semi-automatic filter dedusting" function button when vacuuming wet dirt with the crevice nozzle or upholstery nozzle (optional) when sucking mainly water out of a container.

      • The device switches off automatically when the maximum fluid level is reached.

      • When vacuuming non-conductive liquids (e.g. drill emulsion, oils and grease) the device does not automatically switch off when the container is full. The filling level must be continuously monitored and the container emptied on a timely basis.

      • On completion of wet vacuum cleaning: Clean the flat fold filter using the dedusting function. Clean the electrodes with a brush. Clean the container with a moist cloth and dry it off.

      Clip connection

      The suction hose is equipped with a clip system. All accessory parts with a nominal width of 40 mm can be connected.


      Operation

      Switching on the device

      1. Connect the mains plug.

      2. Switch on the device at the turn switch.

      Semi-automatic filter dedusting

      Note

      Actuating the semi-automatic filter dedusting every 5-10 minutes extends the working time of the flat fold filter.

      Note

      The semi-automatic filter dedusting can only be switched on when the device is switched on.

      1. Press the semi-automatic filter dedusting button 5x. The flat fold filter is then cleaned by a blast of air (pulsing noise).

      Switching off the device

      1. Press the semi-automatic filter dedusting button 5x.

      2. Switch off the device at the turn switch.

      3. Pull out the mains plug.

      Each time after use

      1. Empty the container.

      2. Vacuum off the inside and outside of the device and clean with a moist cloth.

      Storing the device

      1. Store the suction hose and mains cable as shown in the illustration.


      2. Store the device in a dry room and secure it against unauthorised use.

      Transport

      CAUTION

      Failure to observe the weight

      Risk of injury and damage

      Be aware of the weight of the device during transportation.
      1. Remove the suction hose with floor nozzle from the support. Carry the device by the carrying handle and suction pipe.

      2. Load the device by the steering roller bracket and push handle.

      3. Pull the device behind you via the push handle for transporting over longer distances.

      4. When transporting the device in vehicles, secure it to prevent it from slipping or overturning in accordance with the respective valid guidelines.

      Storage

      CAUTION

      Failure to observe the weight

      Risk of injury and damage

      Be aware of the weight of the device during storage.

      The device may only be operated indoors.

      Care and service

      DANGER

      Danger of electric shock

      Injuries due to touching live parts

      Switch off the device.Remove the mains plug.

      Replacing the flat fold filter

      1. Open the filter cover.

      2. Remove the flat fold filter.

      3. Fit the new flat fold filter. During insertion, ensure that the flat fold filter is flush on all sides.

      4. Close the filter cover until it audibly latches into place.

      Cleaning the electrodes

      1. Unlock and remove the suction head.

      2. Clean the electrodes and the gap between the electrodes with a brush.

      3. Fit and lock the suction head.

      Troubleshooting guide

      DANGER

      Danger of electric shock

      Injuries due to touching live parts

      Switch off the device.Remove the mains plug.
      • Suction turbine does not start up 

      • Suction turbine switches off 

      • Suction turbine does not switch on again after emptying the container 

      • Suction power decreases 

      • Escaping dust when vacuuming 

      • The automatic switch-off mechanism (wet vacuum cleaning) does not trigger 

      • Semi-automatic filter dedusting not working 

      • Semi-automatic filter dedusting does not switch off 

      • Semi-automatic filter dedusting cannot be switched on 

      Suction turbine does not start up

      Remedy:

      1. Check the socket and the power supply fuse.

      2. Check the mains cable, mains plug and electrodes on the device.

      3. Switch on the device.

      Suction turbine switches off

      Remedy:

      1. Empty the container.

      Suction turbine does not switch on again after emptying the container

      Remedy:

      1. Switch off the device and wait for 5 seconds. Switch on the device.

      2. Clean the electrodes and the gap between the electrodes with a brush.

      Suction power decreases

      Remedy:

      1. Remove any blockages from the suction nozzle, suction pipe, suction hose or flat fold filter.

      2. Change the filled paper filter bag.

      3. Press the semi-automatic filter dedusting button 5x with the device switched on.

      4. Correctly engage the filter cover.

      5. Replace the flat fold filter.

      6. Check the drain hose for leaks.

      Escaping dust when vacuuming

      Remedy:

      1. Check that the flat fold filter is correctly fitted and correct if necessary.

      2. Replace the flat fold filter.

      The automatic switch-off mechanism (wet vacuum cleaning) does not trigger

      Remedy:

      1. Clean the electrodes and the gap between the electrodes with a brush.

      2. Continuously monitor the filling level when vacuuming non-conductive liquids.

      Semi-automatic filter dedusting not working

      Remedy:

      1. Suction hose not connected.

      Semi-automatic filter dedusting does not switch off

      Remedy:

      1. Contact Customer Service.

      Semi-automatic filter dedusting cannot be switched on

      Remedy:

      1. Contact Customer Service.

      Customer Service department

      If the malfunction cannot be corrected, the device must be checked by the Customer Service department.

      • Suction turbine does not start up 

      • Suction turbine switches off 

      • Suction turbine does not switch on again after emptying the container 

      • Suction power decreases 

      • Escaping dust when vacuuming 

      • The automatic switch-off mechanism (wet vacuum cleaning) does not trigger 

      • Semi-automatic filter dedusting not working 

      • Semi-automatic filter dedusting does not switch off 

      • Semi-automatic filter dedusting cannot be switched on 

      Suction turbine does not start up

      Remedy:

      1. Check the socket and the power supply fuse.

      2. Check the mains cable, mains plug and electrodes on the device.

      3. Switch on the device.

      Suction turbine switches off

      Remedy:

      1. Empty the container.

      Suction turbine does not switch on again after emptying the container

      Remedy:

      1. Switch off the device and wait for 5 seconds. Switch on the device.

      2. Clean the electrodes and the gap between the electrodes with a brush.

      Suction power decreases

      Remedy:

      1. Remove any blockages from the suction nozzle, suction pipe, suction hose or flat fold filter.

      2. Change the filled paper filter bag.

      3. Press the semi-automatic filter dedusting button 5x with the device switched on.

      4. Correctly engage the filter cover.

      5. Replace the flat fold filter.

      6. Check the drain hose for leaks.

      Escaping dust when vacuuming

      Remedy:

      1. Check that the flat fold filter is correctly fitted and correct if necessary.

      2. Replace the flat fold filter.

      The automatic switch-off mechanism (wet vacuum cleaning) does not trigger

      Remedy:

      1. Clean the electrodes and the gap between the electrodes with a brush.

      2. Continuously monitor the filling level when vacuuming non-conductive liquids.

      Semi-automatic filter dedusting not working

      Remedy:

      1. Suction hose not connected.

      Semi-automatic filter dedusting does not switch off

      Remedy:

      1. Contact Customer Service.

      Semi-automatic filter dedusting cannot be switched on

      Remedy:

      1. Contact Customer Service.

      Warranty

      The warranty conditions issued by our relevant sales company apply in all countries. We shall remedy possible malfunctions on your appliance within the warranty period free of cost, provided that a material or manufacturing flaw is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.

      Further information can be found at: www.kaercher.com/dealersearch

      Further warranty information (if available) can be found in the service area of your local Kärcher website under "Downloads".

      Accessories and spare parts

      Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.

      Information on accessories and spare parts can be found at www.kaercher.com.

      Technical data

        

      Electrical connection
      Mains voltage
      120 V
      Phase
      1 ~
      Power frequency
      60 Hz
      Degree of protection
      IPX4
      Protection class
      I
      Rated current
      15 A
      Device performance data
      Tank content
      65 l
      Fluid filling quantity
      49 l
      Air quantity (max.)
      54 l/s
      Vacuum (max.)
      20,0 (200) kPa (mbar)
      Air quantity (max., suction motor)
      2x 66 l/s
      Vacuum (max., suction motor)
      22,5 (225) kPa (mbar)
      Dimensions and weights
      Typical operating weight
      20,7 kg
      Length x width x height
      575 x 490 x 920 mm
      Diameter of the suction hose
      40 mm
      Ambient conditions
      Ambient temperature (max.)
      +40 °C
      Determined values in acc. with EN 60335-2-69
      Sound pressure level LpA
      71 dB(A)
      Uncertainty KpA
      1 dB(A)
      Hand-arm vibration value
      <2,5 m/s2
      Uncertainty K
      0,2 m/s2
      Mains cable
      Power cord type
      SJTOW 3x14 AWG Wb 105°C Vw 1 mm2
      Part number (VEX)
      6.650-789.0
      Cable length
      10 m
      <BackPage>

      Filtersysteme / Filter Systems / Système de filtres

       
       
       
       
      Flachfaltenfilter (Zellulose) *
      Flat pleated filter (cellulose) *
      Filtre plat à plis (cellulose) *
      Flachfaltenfilter (PES) *
      Flat pleated filter (PES) *
      Filtre plat à plis (PES) *
      Papierfiltertüte, 3-lagig *
      Paper filter bag, triple layered *
      Sachet filtre à 3 épaisseurs *
      Spezialfiltertüte, nass
      Special filter bag, wet
      Sachet filtre spécial, mouillé
      Bestellnummer
      Order No.
      Numéro de référence
      6.904-283.0
      6.904-284.0
      6.904-285.0
      6.904-252.0
      Menge
      Quantity
      Quantité
      1
      1
      5
      5
      Normalstäube
      Normal dust
      Poussières normales
      x
      x
      x
      Feinstäube
      Fine dust
      Poussières fines
      x
      x
      x
      Abrasive Stäube
      Abrasive dust
      Poussières abrasives
      x
      x
      x
      x
      Flüssigkeiten, nasser Schmutz
      Liquids, wet dirt
      Liquides, saletès humides
      x
      x

      * Staubklasse M, Rückhaltevermögen ≥ 99,9 %

      * Dust class M, Retention ≥ 99,9 %

      * Classe de poussière M, Conservation ≥ 99,9 %


       

        

       