LogoHD 6/15-4 MX Plus Classic HD 9/20-4 MX Plus Classic
  • General notes
  • Intended use
  • Environmental protection
  • Scope of delivery
  • Safety instructions
  • Operation
  • Safety devices
    • Safety lock
    • Overflow valve
  • Symbols on the device
  • Description of the device
  • Initial startup
    • Initial startup
      • Unpacking
      • Colour coding
    • Installing push handle and hose reel
    • Installing accessories
    • Water connection
      • Connection to a water line
      • Suck water from the container
      • Vent the device
    • Electrical connection
  • Operation
    • High-pressure operation
      • Operation with detergent
      • Recommended cleaning method
  • Interrupting operation
  • Finishing operation
  • Frost protection
  • Transport
  • Storage
  • Care and service
    • Safety inspection/maintenance contract
    • Each time before use
    • Weekly
    • Clean the sieve in the water connection
    • Every 500 operating hours, at least annually
    • Oil change
  • Troubleshooting guide
    • Device does not start

    • Device does not reach required pressure

    • Pump leaking

      Up to 3 drops of water per minute are permissible.

    • Pump knocking

    • Detergent dosing volume too low

  • Accessories and spare parts
  • Warranty
  • Technical data
    • HD 6/15-4 MX Plus Classic
    • HD 9/20-4 MX Plus Classic
  • Declaration of Conformity

      HD 6/15-4 MX Plus Classic
      HD 9/20-4 MX Plus Classic

      97753110 (12/24)

      General notes

      Read these original operating instructions and the enclosed safety instructions before using the device for the first time. Proceed accordingly.

      Keep both books for future reference or for future owners.

      Intended use

      Use this high-pressure cleaner only for the following types of work:

      Use the high-pressure jet for cleaning machines, vehicles, buildings, tools and similar objects.

      We recommend using a rotary nozzle as a special accessory for stubborn soiling.

      The HD...Plus is supplied with a rotary nozzle.

      ATTENTION

      Dirty water leads to premature wear or deposits in the device.

      Clean the device using only clean water, or recycled water that does not exceed the following limits:
      • pH value: 6.5...9.5

      • Electrical conductivity: Conductivity of fresh water + 1200 µS/cm, maximum conductivity 2000 µS/cm

      • Settleable particles (sample volume 1 l, settling time 30 minutes): < 0.5 mg/l

      • Filterable particles: < 50 mg/l, no abrasive substances

      • Hydrocarbons: < 20 mg/l

      • Chloride: < 300 mg/l

      • Sulphate: < 240 mg/l

      • Calcium: < 200 mg/l

      • Total hardness: < 28 °dH, < 50° TH, < 500 ppm (mg CaCO3/l)

      • Iron: < 0.5 mg/l

      • Manganese: < 0.05 mg/l

      • Copper: < 2 mg/l

      • Active chloride: < 0.3 mg/l

      • Free of unpleasant odours

      Environmental protection

      The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.

      Electrical and electronic devices contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which - if handled or disposed of incorrectly - can pose a potential danger to human health and the environment. However, these components are required for the correct operation of the device. Devices marked by this symbol are not allowed to be disposed of together with the household rubbish.

      Notes on the content materials (REACH)

      Current information on content materials can be found at: www.kaercher.de/REACH

      Scope of delivery

      Check the contents for completeness when unpacking. If any accessories are missing or in the event of any shipping damage, please notify your dealer.

      Safety instructions

      • It is essential that you read the safety instructions 5.951-949.0 before initial start-up.

      • Observe the national regulations for liquid jet cleaners.

      • Observe the national accident prevention regulations. Liquid jet cleaners must be tested regularly. The test result must be recorded in writing.

      • Do not modify the device or accessories.

      Operation

      • *Determine the maximum permissible system impedance Zmax 0.025 Ω in the equipment instruction manual and instruct the users to determine in consultation with the supply authority, if necessary, that the equipment is connected only to a supply of that impedance or less.

      Safety devices

      CAUTION

      Risk of injury due to missing or modified safety devices!

      Safety devices are provided for your own protection.

      Do not bypass, remove or render ineffective any safety devices.

      Safety lock

      The safety lock on the high-pressure gun prevents the device from being switched on inadvertently.

      Overflow valve

      If the high-pressure gun is closed, the overflow valve opens and the entire water volume will flow back to the pump suction side.

      The overflow valve is set by the manufacturer and sealed. Setting shall only be carried out by Customer Service.

      Symbols on the device

      Do not aim the high-pressure jet at persons, animals, live electrical equipment or the device itself.
      Protect the device against frost.
      According to applicable regulations, the device must never be used with the drinking water network without a system separator. Ensure that the connection to your house water system, with which the high-pressure cleaner is operated, is equipped with a system separator according to EN 12729 type BA. Water that has flowed through a system separator is classified as undrinkable. Always connect the system separator to the water inlet and never directly to the device.

      WARNING

      The high nozzle outlet speed of the high-pressure water jet results in a high noise level that can cause discomfort or hearing damage (e.g. tinnitus) to persons in the immediate vicinity. A continuously high noise level can result in deafness.

      • Wear the prescribed personal protective equipment.

      • High noise levels can impair vocal communication and impair or prevent your ability to perceive acoustic warning signals. Never work alone. A second person must be present outside the work area.

      WARNING

      • The appliance is heavy and the electric control box has weak connection with motor, so please don’t lift the machine by it during transportation.

      Description of the device


      1. Cable hook
      2. Push handle
      3. Storage for spray lance and trigger gun
      4. Hose holder
      5. Fasteners
      6. Power switch
      7. Wheels
      8. Accessory storage
      9. Cover
      10. Hose reel
      11. Unloader
      12. Water outlet
      13. Water inlet
      14. Filter
      15. Oil level window
      16. Oil drain plug
      17. Oil fill plug
      18. Electric control box
      19. Dirt blaster
      20. Screw connection part
      21. Nozzle
      22. Spray lance
      23. Trigger gun
      24. Safety lock
      25. Trigger
      26. High pressure hose

      Initial startup

      Initial startup

      DANGER

      Danger of injury from electric shock

      Only allow authorised technical specialists to install the water supply, electrical connections and high-pressure network.

      Unpacking

      1. Check the contents of the package when unpacking.

      2. Notify the dealer immediately in the case of shipping damage.

      Colour coding

      • Control elements for the cleaning process are yellow.

      Installing push handle and hose reel

      1. Insert the push handle into the machine.


      2. Use fasteners to fix the holes of the lower part of the machine and the hose reel.


      3. Secure the higher part of the machine and the hose reel with latches. Secure the latches with fasteners.


      Installing accessories

      1. Fix the nozzle onto spray lance with screw connection part.

      2. Connect the spray lance to the trigger gun.

      3. Connect high pressure hose to water outlet and trigger gun.


      4. Connect the adapter to the water inlet.

      Water connection

      Connection to a water line

      WARNING

      Health risk from return flow of contaminated water into the drinking water network.

      Observe the regulations of your water supply company.

      According to applicable regulations, the device must never be used with the drinking water network without a system separator. Use a system separator from KÄRCHER or a system separator as per EN 12729 Type BA. Water that has flowed through a system separator is classified as undrinkable. Always connect the system separator to the water supply and never directly to the water connection on the device.

      1. Check the feed pressure, input temperature and input amount of the water supply. See the "Technical data" section for the requirements.

      2. Connect the system separator and water connection of the device with a hose (minimum length 7.5 m, minimum diameter 1”).

        The supply hose is not included in the scope of delivery.

      3. Open the water inlet.

      Suck water from the container

      1. Screw the suction hose (order number 4.440-207.0) and filter (order number 4.730-012.0) onto the water connection.

      2. Vent the device.

      Vent the device

      1. Unscrew the nozzle from the spray lance.

      2. Allow the device to run until the escaping water is free of air bubbles.

      3. In the case of venting problems, allow the device to run for 10 seconds and then switch it off. Repeat the procedure several times.

      4. Switch off the device.

      5. Screw the nozzle back in place.

      Electrical connection

      DANGER

      Risk of injury from electric shock

      Use a plug to connect the device to the mains grid. Permanent connection to the mains grid is prohibited. The plug is used for disconnection from the mains.

      See the type plate or technical data for the connection values.

      1. Unwind the mains cable and place it on the ground.

      2. Plug the mains plug into the socket.

      Operation

      DANGER

      Risk of injury from the high-pressure water jet

      Never fasten the trigger in the actuated position.Do not use the high-pressure gun when the safety lock is damaged.Push the safety latch of the high-pressure gun forwards every time before starting work with the device.

      High-pressure operation

      Note

      • The device is equipped with a pressure switch. The motor only starts up when the high-pressure gun is open.

      • The high-pressure hose should be kept away from sharp edges.

      • The Servo Control is forbidden in the machine, as it can lead to higher wear of the overflow and cause damages.

      1. Open the water supply.

      2. Set the power switch to "I".

      3. Open the safety lock of the high-pressure gun.

      4. Aim the high-pressure gun at the object to be cleaned.

      5. Open the high-pressure gun and start the cleaning operation.

      Operation with detergent

      Note

      A foam lance (optional) is needed for operating with detergent.

      WARNING

      Risk of injury from detergent

      Health risk due to incorrect handling of detergents.

      Adhere to the safety instructions stated on the detergent packaging.

      ATTENTION

      Risk of damage from unsuitable detergents

      Using unsuitable detergents may damage the device and the item being cleaned.

      Use only detergents approved by KÄRCHER.Observe the dosing recommendations and notes provided with the detergent.Use detergents sparingly to help conserve the environment.

      KÄRCHER detergents ensure fault-free operation. Please feel free to request a consultation, our catalogue or our detergent information sheets.

      1. Fill the detergent into the container of the foam lance. (Follow the dosage instructions on the detergent bottle.)

      Recommended cleaning method

      1. Spray the detergent sparingly on the dry surface and let it work for a while (do not let it dry).

      2. Rinse off the loosened dirt with the high-pressure jet.

      Interrupting operation

      1. Release the trigger and the device will switch off.

      2. Pull the trigger and the device will switch on again.

      Finishing operation

      1. Close off the water inlet.

      2. Open the high-pressure gun.

      3. Set the power switch to "I" and allow the device to run for 5 to 10 seconds.

      4. Close the high-pressure gun.

      5. Turn the power switch to "0/OFF".

      6. Pull the mains plug out of the socket only when your hands are dry.

      7. Disconnect the water inlet.

      8. Open the high-pressure gun until the device is completely depressurised.

      9. Push the safety lock forward to lock the trigger gun.

      Frost protection

      ATTENTION

      Frost destroys the device if it is not completely drained of water.

      Store the device in a frost-free location.

      If frost-free storage is not possible:

      1. Drain the water.

      2. Pump commonly available anti-freeze through the device.

      3. Allow the device for run for a maximum of 1 minute until the pump and lines are empty.

      Note

      Use commonly available, Glycol-based vehicle anti-freeze. Observe the handling instructions of the anti-freeze manufacturer.

      Transport

      CAUTION

      Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

      1. Push the push handle down and pull or push the appliance.

      2. When transporting in vehicles, secure the appliance according to the guidelines from slipping and tripping over.

      Storage

      CAUTION

      Risk of injury, risk of damage.

      Be aware of the weight of the device during storage.
      1. Store the device indoors only.

      Care and service

      DANGER

      Risk of injury due to inadvertently starting up device and also due to electric shock.

      Switch off the device immediately and unplug the mains plug before performing work.

      Safety inspection/maintenance contract

      You can agree on regular safety inspections or close a maintenance contract with your dealer. Please seek advice on this.

      Each time before use

      1. Check the power cable for damage and have a damaged cable replaced immediately by the authorised Customer Service or a qualified electrician.

      2. Check the high-pressure hose for damage and replace a damaged high-pressure hose immediately.

      3. Check the device for leaks. 3 drops of water per minute are permissible. Contact Customer Service in the case of more serious leaks.

      Weekly

      1. Clean the sieve in the water connection.

      Clean the sieve in the water connection

      1. Unscrew water filter.

      2. Pull out and clean the sieve.



      3. Put the sieve in its place.

      4. Screw water filter.


      Every 500 operating hours, at least annually

      1. Have the device maintained by Customer Service.

      2. Changing oil.

      Oil change

      Note

      See the "Technical data" section for the oil volume and type

      1. Unscrew oil drain and fill plug.

      2. Drain the oil in a collection basin.

      3. Wait until the oil has drained completely.

      4. Screw the oil drain plug and tighten it. Torque 7...12Nm.

      5. Fill in new oil slowly and air bubbles should go out. The oil level must be at the center of the oil level window.

      6. Screw the oil fill plug and tighten it. Torque 7...12Nm.

      Troubleshooting guide

      DANGER

      Risk of injury due to inadvertently starting up device and also due to electric shock.

      Switch off the device immediately and unplug the mains plug before performing work.Have electrical components checked and repaired by the authorised Customer Service.In case of any malfunctions not mentioned in this chapter, contact the authorised Customer Service when in doubt or when you have been explicitly advised to do so.
      • Device does not start 

      • Device does not reach required pressure 

      • Pump leakingUp to 3 drops of water per minute are permissible. 

      • Pump knocking 

      • Detergent dosing volume too low 

      Device does not start

      Remedy:

      • Check the power cable for damage.

      • Check the mains voltage.

      • If the device overheats:

        1. Set the power switch to "0".

        2. Allow the device to cool for at least 15 minutes.

        3. Set the power switch to "1".

      • Reset power switch.

      • Contact Customer Service in the case of electrical faults.

      Device does not reach required pressure

      Remedy:

      • Check the size of the nozzle and compare with the required size specified in the "Technical data" section.

      • Vent the device, see section "Venting the device".

      • Clean the sieve in the water connection.

      • Check the water supply volume and compare with the required volume specified in the "Technical data" section.

      • Clean the nozzle.

      • Contact Customer Service if necessary.

      Pump leaking

      Up to 3 drops of water per minute are permissible.

      Remedy:

      • In case of more serious leaks, have the device checked by Customer Service.

      Pump knocking

      Remedy:

      • Check the water supply line for leaks.

      • Vent the device, see section "Venting the device".

      • Contact Customer Service if necessary.

      Detergent dosing volume too low

      Remedy:

      • Refill the foam nozzle cup.

      • Plug a larger blender onto the suction hose.

      • Check the suction hose and foam nozzle for detergent deposits. Remove deposits using lukewarm water.

      Accessories and spare parts

      Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.

      Information on accessories and spare parts can be found at www.kaercher.com.

      Warranty

      The warranty conditions issued by our relevant sales company apply in all countries. We shall remedy possible malfunctions on your appliance within the warranty period free of cost, provided that a material or manufacturing flaw is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.

      Further information can be found at: www.kaercher.com/dealersearch

      Further warranty information (if available) can be found in the service area of your local Kärcher website under "Downloads".

      Technical data

      • HD 6/15-4 MX Plus Classic 

      • HD 9/20-4 MX Plus Classic 

      HD 6/15-4 MX Plus Classic

      Electrical connection
      Voltage
      220 - 240
      Phase
      1 ~
      Frequency
      50 Hz
      Maximum permissible mains grid impedance
      0.332 Ω
      Power rating
      3.4 kW
      Degree of protection
      IPX5
      Power protection (slow-blowing)
      15 A
      Extension cable, 30 m
      2.5 mm2
      Water connection
      Feed pressure (max.)
      1.0 (10) MPa (bar)
      Input temperature (max.)
      60 °C
      Input amount (min.)
      900 (15) l/h (l/min)
      Suction height (max.)
      1.0 m
      Device performance data
      Nozzle size of standard nozzle
      035
      Water flow rate
      600 (10) l/h (l/min)
      Maximum flow rate
      650 (10.8) l/min
      Operating pressure
      3.5 (35)...15 (150) MPa (bar)
      Operating pressure (max.)
      19 (190) MPa (bar)
      High-pressure gun recoil force
      29 N
      Dimensions and weights
      Weight
      52 kg
      Length x width x height
      740x528x952 mm
      Oil volume
      430 ml
      Oil type
      15W40
      Determined values in acc. with EN 60335-2-79
      Hand-arm vibration value
      1.92 m/s2
      Uncertainty K
      0.3 m/s2
      Sound pressure level LpA
      75.3 dB(A)
      Uncertainty KpA
      2.5 dB(A)
      Sound power level LWA + uncertainty KWA
      91 dB(A)

      HD 9/20-4 MX Plus Classic

      Electrical connection
      Voltage
      380 - 415
      Phase
      3 ~
      Frequency
      50 Hz
      Maximum permissible mains grid impedance
      0.238 Ω
      Power rating
      6.5 kW
      Degree of protection
      IPX5
      Power protection (slow-blowing)
      16 A
      Extension cable, 30 m
      2.5 mm2
      Water connection
      Feed pressure (max.)
      1.0 (10) MPa (bar)
      Input temperature (max.)
      60 °C
      Input amount (min.)
      1200 (20) l/h (l/min)
      Suction height (max.)
      1.0 m
      Device performance data
      Nozzle size of standard nozzle
      047
      Water flow rate
      900 (15) l/h (l/min)
      Maximum flow rate
      950 (15.8) l/min
      Operating pressure
      3.5 (35)...20 (200) MPa (bar)
      Operating pressure (max.)
      24 (240) MPa (bar)
      High-pressure gun recoil force
      50 N
      Dimensions and weights
      Weight
      72 kg
      Length x width x height
      740x528x952 mm
      Oil volume
      580 ml
      Oil type
      15W40
      Determined values in acc. with EN 60335-2-79
      Hand-arm vibration value
      1.92 m/s2
      Uncertainty K
      0.3 m/s2
      Sound pressure level LpA
      74.3 dB(A)
      Uncertainty KpA
      2.5 dB(A)
      Sound power level LWA + uncertainty KWA
      90.1 dB(A)

      Declaration of Conformity

      We hereby declare that the product described below complies with the relevant provisions of the following UK Regulations, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the product is modified without our prior approval.

      Product: High-pressure cleaner

      Type: 1.367-xxx

      Currently applicable UK Regulations

      S.I. 2008/1597 (as amended)

      S.I. 2012/3032 (as amended)

      S.I. 2016/1091 (as amended)

      S.I. 2001/1701 (as amended)

      S.I. 2010/2617 (as amended)

      Commission Regulation(s)

      (EU) 2019/1781

      Designated standards used

      EN 60335-1

      EN 60335-2-79

      EN IEC 63000: 2018

      EN 55014-1: 2017 + A11: 2020

      EN 55014-2: 1997 + A1: 2001 + A2: 2008

      EN 61000-3-2: 2014

      EN 61000-3-3: 2013

      EN 62233: 2008

      National standards used

      -

      Applied conformity assessment procedure

      S.I. 2001/1701 (as amended): Schedule 8

      Sound power level dB(A)

      HD 6/15-4 MX Plus Classic

      Measured: 89

      Guaranteed: 91

      HD 9/20-4 MX Plus Classic

      Measured: 88

      Guaranteed: 91

       

      Measured:

      Guaranteed:

       

      Measured:

      Guaranteed:

       

      Measured:

      Guaranteed:

      The signatories act on behalf of and with the authority of the company management.


      Documentation supervisor:

      S. Reiser

      Alfred Kärcher SE & Co. KG

      Alfred-Kärcher-Str. 28 - 40

      71364 Winnenden (Germany)

      Ph.: +49 7195 14-0

      Fax: +49 7195 14-2212

      Winnenden, /11/01

      <BackPage>